Model-based ultrasound temperature visualization during and following HIFU exposure.

This paper describes the application of signal processing techniques to improve the robustness of ultrasound feedback for displaying changes in temperature distribution in treatment using high-intensity focused ultrasound (HIFU), especially at the low signal-to-noise ratios that might be expected in in vivo abdominal treatment. Temperature estimation is based on the local displacements in ultrasound images taken during HIFU treatment, and a method to improve robustness to outliers is introduced. The main contribution of the paper is in the application of a Kalman filter, a statistical signal processing technique, which uses a simple analytical temperature model of heat dispersion to improve the temperature estimation from the ultrasound measurements during and after HIFU exposure. To reduce the sensitivity of the method to previous assumptions on the material homogeneity and signal-to-noise ratio, an adaptive form is introduced. The method is illustrated using data from HIFU exposure of ex vivo bovine liver. A particular advantage of the stability it introduces is that the temperature can be visualized not only in the intervals between HIFU exposure but also, for some configurations, during the exposure itself.

[1]  Jeffrey C Bamber,et al.  Imaging of temperature-induced echo strain: preliminary in vitro study to assess feasibility for guiding focused ultrasound surgery. , 2004, Ultrasound in medicine & biology.

[2]  H. O'neil Theory of Focusing Radiators , 1949 .

[3]  Vic Barnett,et al.  Outliers in Statistical Data , 1980 .

[4]  D. Widder The heat equation , 1975 .

[5]  P. Meaney,et al.  A 3-D finite-element model for computation of temperature profiles and regions of thermal damage during focused ultrasound surgery exposures. , 1998, Ultrasound in medicine & biology.

[6]  J A de Zwart,et al.  Hyperthermia by MR‐guided focused ultrasound: Accurate temperature control based on fast MRI and a physical model of local energy deposition and heat conduction , 2000, Magnetic resonance in medicine.

[7]  D. Cranston,et al.  High intensity focused ultrasound: surgery of the future? , 2003, The British journal of radiology.

[8]  F. Kallel,et al.  A Least-Squares Strain Estimator for Elastography , 1997, Ultrasonic imaging.

[9]  Y. Bar-Shalom Tracking and data association , 1988 .

[10]  L A Crum,et al.  Real-time visualization of high-intensity focused ultrasound treatment using ultrasound imaging. , 2001, Ultrasound in medicine & biology.

[11]  Christakis Damianou,et al.  High intensity focused ultrasound ablation of kidney guided by MRI. , 2004, Ultrasound in medicine & biology.

[12]  Thia Kirubarajan,et al.  Estimation with Applications to Tracking and Navigation: Theory, Algorithms and Software , 2001 .

[13]  Penny Probert Smith,et al.  Estimating a parametric model of temperature distribution from an ultrasound image sequence during HIFU therapy , 2006, 3rd IEEE International Symposium on Biomedical Imaging: Nano to Macro, 2006..

[14]  L A Crum,et al.  Use of overpressure to assess the role of bubbles in focused ultrasound lesion shape in vitro. , 2001, Ultrasound in medicine & biology.

[15]  H. H. Penns Analysis of tissue and arterial blood temperatures in the resting human forearm , 1948 .

[16]  Guoliang Ye,et al.  A Model Based Approach To Monitor Temperature During HIFU Thermal Therapy , 2007 .

[17]  R. Seip,et al.  Noninvasive estimation of tissue temperature response to heating fields using diagnostic ultrasound , 1995, IEEE Transactions on Biomedical Engineering.

[18]  Bruno Quesson,et al.  Magnetic resonance temperature imaging for guidance of thermotherapy , 2000, Journal of magnetic resonance imaging : JMRI.

[19]  C R Hill,et al.  Lesion development in focused ultrasound surgery: a general model. , 1994, Ultrasound in medicine & biology.

[20]  R. Mehra On the identification of variances and adaptive Kalman filtering , 1970 .

[21]  P. VanBaren,et al.  Two-dimensional temperature estimation using diagnostic ultrasound , 1998, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[22]  G Brix,et al.  Quantitative MR temperature monitoring of high-intensity focused ultrasound therapy. , 1999, Magnetic resonance imaging.

[23]  Guoliang Ye Model-based ultrasonic temperature estimation for monitoring HIFU therapy , 2008 .

[24]  Mathieu Pernot,et al.  3-D real-time motion correction in high-intensity focused ultrasound therapy. , 2004, Ultrasound in medicine & biology.

[25]  M. Wan,et al.  Monitoring imaging of lesions induced by high intensity focused ultrasound based on differential ultrasonic attenuation and integrated backscatter estimation. , 2007, Ultrasound in medicine & biology.

[26]  G. Haar,et al.  6th International Symposium on Therapeutic Ultrasound , 2007 .

[27]  Jeffrey C. Bamber,et al.  Physical principles of medical ultrasonics , 2004 .

[28]  M. Fink,et al.  Temperature estimation using ultrasonic spatial compound imaging , 2004, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[29]  Guoliang Ye,et al.  A model-based displacement outlier removal algorithm for ultrasonic temperature estimation , 2008, 2008 IEEE Ultrasonics Symposium.