Characterization of hematopoietic cells arising on the textured surface of left ventricular assist devices.

BACKGROUND Textured biomaterial surfaces in implantable left ventricular assist devices induce development of a nonthrombotic neointimal surface and allow elimination of anticoagulation therapy in device recipients. Characterization of the hematopoietic cells formed within the neointimal surfaces of these devices will contribute to our understanding of this unique neointima. METHODS The blood-contacting surface of seven ThermoCardiosystems left ventricular assist devices was removed, washed with phosphate-buffered saline solution, and digested with 0.1% collagenase for 15 to 20 minutes. The hematopoietic cells released from the explants were isolated and analyzed by flow cytometry and immuno-histochemical staining. RESULTS More than 80% +/- 6% of hematopoietic cells isolated in this fashion are of myelomonocytic origin and express CD14, CD15, and CD33 surface molecules. Four percent of cells express the CD34 surface marker, which suggests that the neointima is colonized by pluripotent hematopoietic stem cells. Continuous culture of these hematopoietic cells in the presence of the cytokines interleukin-3, c-kit ligand, granulocyte colony-stimulating factor resulted in tenfold expansion by day 7 and 25-fold expansion by day 14. CONCLUSIONS Pluripotent hematopoietic cells with a high proliferative capacity colonize textured surfaces of left ventricular assist devices and may contribute to the development of a biologically nonthrombogenic neointima.

[1]  U. Hochgeschwender,et al.  Preferential expression of a defined T-cell receptor β-chain gene in hapten-specific cytotoxic T-cell clones , 1986, Nature.

[2]  M C Oz,et al.  Artificial circulatory support with textured interior surfaces. A counterintuitive approach to minimizing thromboembolism. , 1994, Circulation.

[3]  Henri Ulrich,et al.  Emerging Biomedical Applications of Polyurethane Elastomers , 1983 .

[4]  B. Ziegler,et al.  Phenotype analysis of hematopoietic CD34+ cell populations derived from human umbilical cord blood using flow cytometry and cDNA-polymerase chain reaction. , 1994, Blood.

[5]  M. Greaves,et al.  Compartmentalization of a haematopoietic growth factor (GM-CSF) by glycosaminoglycans in the bone marrow microenvironment , 1987, Nature.

[6]  A Coumbe,et al.  Neo-intimal development on textured biomaterial surfaces during clinical use of an implantable left ventricular assist device. , 1990, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[7]  O H Frazier,et al.  Multicenter clinical evaluation of the HeartMate 1000 IP left ventricular assist device. , 1992, The Annals of thoracic surgery.

[8]  Stuart L. Cooper,et al.  Polyurethanes In Medicine , 1986 .

[9]  P M Portner,et al.  Clinical experience with the Novacor ventricular assist system. Bridge to transplantation and the transition to permanent application. , 1991, The Journal of thoracic and cardiovascular surgery.

[10]  G. Stein,et al.  Molecular Approaches to the Characterization of Cell and Blood/Biomaterial Interactions , 1992, Journal of cardiac surgery.

[11]  O. Frazier,et al.  Clinical experience with textured blood contacting surfaces in ventricular assist devices. , 1987, ASAIO transactions.

[12]  P. Lansdorp,et al.  Sequential generations of hematopoietic colonies derived from single nonlineage-committed CD34+CD38- progenitor cells. , 1991, Blood.

[13]  A. Snyder,et al.  Approaches to the artificial heart. Invited speaker. , 1981, Surgery.

[14]  M. Szycher,et al.  Blood Compatible Polyurethane Elastomers , 1987, Journal of biomaterials applications.

[15]  S. Rafii,et al.  Isolation and characterization of human bone marrow microvascular endothelial cells: hematopoietic progenitor cell adhesion , 1994 .

[16]  L. Lajtha,et al.  Conditions controlling the proliferation of haemopoietic stem cells in vitro , 1977, Journal of cellular physiology.

[17]  A. Keating,et al.  Sensitive detection and enumeration of CD34+ cells in peripheral and cord blood by flow cytometry. , 1994, Experimental hematology.

[18]  I. Koshino,et al.  Use of liver slices for an artificial liver. , 1979, Transactions - American Society for Artificial Internal Organs.

[19]  H. Harasaki,et al.  Approaches to the artificial heart. , 1984, Transplantation proceedings.