Convergence behavior of high-resolution finite element models of trabecular bone.

The convergence behavior of finite element models depends on the size of elements used, the element polynomial order, and on the complexity of the applied loads. For high-resolution models of trabecular bone, changes in architecture and density may also be important. The goal of this study was to investigate the influence of these factors on the convergence behavior of high-resolution models of trabecular bone. Two human vertebral and two bovine tibial trabecular bone specimens were modeled at four resolutions ranging from 20 to 80 microns and subjected to both compressive and shear loading. Results indicated that convergence behavior depended on both loading mode (axial versus shear) and volume fraction of the specimen. Compared to the 20 microns resolution, the differences in apparent Young's modulus at 40 microns resolution were less than 5 percent for all specimens, and for apparent shear modulus were less than 7 percent. By contrast, differences at 80 microns resolution in apparent modulus were up to 41 percent, depending on the specimen tested and loading mode. Overall, differences in apparent properties were always less than 10 percent when the ratio of mean trabecular thickness to element size was greater than four. Use of higher order elements did not improve the results. Tissue level parameters such as maximum principal strain did not converge. Tissue level strains converged when considered relative to a threshold value, but only if the strains were evaluated at Gauss points rather than element centroids. These findings indicate that good convergence can be obtained with this modeling technique, although element size should be chosen based on factors such as loading mode, mean trabecular thickness, and the particular output parameter of interest.

[1]  E. Wilson,et al.  A non-conforming element for stress analysis , 1976 .

[2]  Thomas J. R. Hughes,et al.  LARGE-SCALE VECTORIZED IMPLICIT CALCULATIONS IN SOLID MECHANICS ON A CRAY X-MP/48 UTILIZING EBE PRECONDITIONED CONJUGATE GRADIENTS. , 1986 .

[3]  R. B. Ashman,et al.  Elastic modulus of trabecular bone material. , 1988, Journal of biomechanics.

[4]  S. Cowin,et al.  On the dependence of the elasticity and strength of cancellous bone on apparent density. , 1988, Journal of biomechanics.

[5]  J H Keyak,et al.  Automated three-dimensional finite element modelling of bone: a new method. , 1990, Journal of biomedical engineering.

[6]  H. Skinner,et al.  Three-dimensional finite element modelling of bone: effects of element size. , 1992, Journal of biomedical engineering.

[7]  N. Kikuchi,et al.  A homogenization sampling procedure for calculating trabecular bone effective stiffness and tissue level stress. , 1994, Journal of biomechanics.

[8]  S A Goldstein,et al.  The relationship between the structural and orthogonal compressive properties of trabecular bone. , 1994, Journal of biomechanics.

[9]  R. Huiskes,et al.  A new method to determine trabecular bone elastic properties and loading using micromechanical finite-element models. , 1995, Journal of biomechanics.

[10]  R. Huiskes,et al.  Direct mechanics assessment of elastic symmetries and properties of trabecular bone architecture. , 1996, Journal of biomechanics.

[11]  B. van Rietbergen,et al.  COMPUTATIONAL STRATEGIES FOR ITERATIVE SOLUTIONS OF LARGE FEM APPLICATIONS EMPLOYING VOXEL DATA , 1996 .

[12]  T M Keaveny,et al.  Three-dimensional imaging of trabecular bone using the computer numerically controlled milling technique. , 1997, Bone.

[13]  C. Simmons,et al.  Method‐Based Differences in the Automated Analysis of the Three‐Dimensional Morphology of Trabecular Bone , 1997, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[14]  R. Huiskes,et al.  Fabric and elastic principal directions of cancellous bone are closely related. , 1997, Journal of biomechanics.

[15]  John H. Kinney,et al.  Elastic constants of cellular structures , 1997 .

[16]  John H. Kinney,et al.  DEFORMATION AND FAILURE IN CELLULAR MATERIALS , 1997 .

[17]  P Rüegsegger,et al.  The quality of trabecular bone evaluated with micro-computed tomography, FEA and mechanical testing. , 1997, Studies in health technology and informatics.

[18]  S. Majumdar,et al.  Impact of spatial resolution on the prediction of trabecular architecture parameters. , 1998, Bone.

[19]  P. Rüegsegger,et al.  Finite element analysis of trabecular bone structure: a comparison of image-based meshing techniques. , 1998, Journal of biomechanics.

[20]  Ph. D Tony M. Keaveny Mechanistic Approaches to Analysis of Trabecular Bone , 1998 .

[21]  T. Keaveny,et al.  Yield strain behavior of trabecular bone. , 1998, Journal of biomechanics.

[22]  S. Goldstein,et al.  Finite‐element modeling of trabecular bone: Comparison with mechanical testing and determination of tissue modulus , 1998, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[23]  R. Huiskes,et al.  Relationships between bone morphology and bone elastic properties can be accurately quantified using high‐resolution computer reconstructions , 1998, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[24]  J. Kinney,et al.  Numerical errors and uncertainties in finite-element modeling of trabecular bone. , 1998, Journal of biomechanics.

[25]  J. Kinney,et al.  The Relationship Between Three‐Dimensional Connectivity and the Elastic Properties of Trabecular Bone , 1998, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[26]  R E Guldberg,et al.  The accuracy of digital image-based finite element models. , 1998, Journal of biomechanical engineering.

[27]  T M Keaveny,et al.  A cellular solid criterion for predicting the axial-shear failure properties of bovine trabecular bone. , 1999, Journal of biomechanical engineering.

[28]  P Rüegsegger,et al.  Tissue stresses and strain in trabeculae of a canine proximal femur can be quantified from computer reconstructions. , 1999, Journal of biomechanics.

[29]  David P. Fyhrie,et al.  The impact of boundary conditions and mesh size on the accuracy of cancellous bone tissue modulus determination using large-scale finite-element modeling , 1999 .