Transient Stability Analysis of Grid- Connected Converters with Power Synchronization Control

The power synchronization control (PSC) has been increasingly used with voltage-source converters (VSCs) connected to the weak ac grid. This paper presents an in-depth analysis on the transient stability of the PSC-VSC by means of the phase portrait. It is revealed that the PSC-VSC will maintain synchronization with the grid as long as there are equilibrium points after the transient disturbance. In contrast, during grid faults without any equilibrium points, the critical-clearing angle (CCA) for the PSC-VSC is identified, which is found equal to the power angle of the unstable equilibrium point of the postfault operation. This fixed CCA facilitates the design of power system protection. Moreover, it is also found that the PSC-VSC can still resynchronize with the grid after around one cycle of oscillation, even if the fault-clearing angle is beyond the CCA. This feature reduces the risk of system collapse caused by the delayed fault clearance. These findings are corroborated by simulations and experimental tests.

[1]  Hans-Peter Nee,et al.  Analysis of Stability Limitations of a VSC-HVDC Link Using Power-Synchronization Control , 2011, IEEE Transactions on Power Systems.

[2]  Yasser Abdel-Rady I. Mohamed,et al.  Power Synchronization Control for Grid-Connected Current-Source Inverter-Based Photovoltaic Systems , 2016, IEEE Transactions on Energy Conversion.

[3]  Se-Kyo Chung,et al.  A phase tracking system for three phase utility interface inverters , 2000 .

[4]  Impedance and Damping Characteristics of Grid-Connected VSCs With Power Synchronization Control Strategy , 2015, IEEE Transactions on Power Systems.

[5]  Massimo Bongiorno,et al.  Input-Admittance Calculation and Shaping for Controlled Voltage-Source Converters , 2007, IEEE Transactions on Industrial Electronics.

[6]  Claus Leth Bak,et al.  Instability of Wind Turbine Converters During Current Injection to Low Voltage Grid Faults and PLL Frequency Based Stability Solution , 2014, IEEE Transactions on Power Systems.

[7]  Lidong Zhang,et al.  Modeling and Control of VSC-HVDC Links Connected to Island Systems , 2011, IEEE Transactions on Power Systems.

[8]  Daniel Remón Rodríguez Impact of solar PV plants with synchronous power controllers on power system stability , 2017 .

[9]  Lakshan Piyasinghe,et al.  Impedance-model-based MIMO analysis of power synchronization control , 2018 .

[10]  Hans-Peter Nee,et al.  Interconnection of Two Very Weak AC Systems by VSC-HVDC Links Using Power-Synchronization Control , 2011, IEEE Transactions on Power Systems.

[11]  Heng Wu,et al.  Transient Stability Impact of the Phase-Locked Loop on Grid-Connected Voltage Source Converters , 2018, 2018 International Power Electronics Conference (IPEC-Niigata 2018 -ECCE Asia).

[12]  Bo Wen,et al.  Analysis of Phase-Locked Loop Low-Frequency Stability in Three-Phase Grid-Connected Power Converters Considering Impedance Interactions , 2015, IEEE Transactions on Industrial Electronics.

[13]  Lidong Zhang Modeling and Control of VSC-HVDC Links Connected to Weak AC Systems , 2010 .

[14]  David Chan Tat Wai,et al.  A novel technique for high impedance fault identification , 1998 .

[15]  V. Blasko,et al.  A new mathematical model and control of a three-phase AC-DC voltage source converter , 1997 .

[16]  Frede Blaabjerg,et al.  Overview of Control and Grid Synchronization for Distributed Power Generation Systems , 2006, IEEE Transactions on Industrial Electronics.

[17]  Hao Yuan,et al.  Modeling of Grid-Connected VSCs for Power System Small-Signal Stability Analysis in DC-Link Voltage Control Timescale , 2017, IEEE Transactions on Power Systems.

[18]  Frede Blaabjerg,et al.  Passivity-Based Stability Assessment of Grid-Connected VSCs—An Overview , 2016, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[19]  D. Lathrop Nonlinear Dynamics and Chaos: With Applications to Physics, Biology, Chemistry, and Engineering , 2015 .

[20]  A. Gole,et al.  Impact of Short-Circuit Ratio and Phase-Locked-Loop Parameters on the Small-Signal Behavior of a VSC-HVDC Converter , 2014, IEEE Transactions on Power Delivery.

[21]  Lu Liu,et al.  Synchronization and Reactive Current Support of PMSG-Based Wind Farm During Severe Grid Fault , 2018, IEEE Transactions on Sustainable Energy.

[22]  Z ZhouJenny Impact of short circuit ratio and phase locked loop parameters on the small-signal behaviour of a VSC-HVdc converter , 2016 .

[23]  Ying,et al.  Stability Enhancement and Blackout Prevention by VSC Based HVDC , 2012 .

[24]  Lidong Zhang,et al.  Offshore wind integration to a weak grid by VSC-HVDC links using power-synchronization control: A case study , 2014, 2014 IEEE PES General Meeting | Conference & Exposition.

[25]  Babu Narayanan,et al.  POWER SYSTEM STABILITY AND CONTROL , 2015 .

[26]  Xinbo Ruan,et al.  A Real-Time Computation Method With Dual Sampling Mode to Improve the Current Control Performance of the $LCL$-Type Grid-Connected Inverter , 2015, IEEE Transactions on Industrial Electronics.

[27]  Hans-Peter Nee,et al.  Power-Synchronization Control of Grid-Connected Voltage-Source Converters , 2010, IEEE Transactions on Power Systems.

[28]  Stavros A. Papathanassiou,et al.  Grid Code Compatibility of VSC-HVDC Connected Offshore Wind Turbines Employing Power Synchronization Control , 2016, IEEE Transactions on Power Systems.