Air-cooling of direct-coupled ultrasound applicators for interstitial hyperthermia and thermal coagulation.

The feasibility of using air-cooling to improve the thermal penetration of direct-coupled interstitial ultrasound (US) applicators was investigated using biothermal simulations, bench experiments, phantom testing, and in vivo thermal dosimetry. Two applicator configurations using tubular US transducers were constructed and tested. The first design, intended for simultaneous thermobrachy-therapy, utilizes a 2.5 mm OD transducer with a central lumen to accommodate a radiation source from remote afterloaders. The second applicator consists of a 2.2 mm OD transducer designed for coagulative thermal therapy. Both designs provide cooling of the inner transducer surface by the counterflow of chilled air or CO2 gas through the annulus of the enclosed applicator. The average convective heat transfer (ha) associated with each applicator was determined empirically from curve-fits of radial steady-state temperatures measured in a tissue-mimicking phantom. High levels of convective heat transfer (ha > 500 W m-2 degrees C-1) were demonstrated in both designs at relatively low flow rates (< 5 L min-1). Transient and steady-state radial heating profiles were also measured in vivo (pig thigh muscle) with and without cooling. The therapeutic radius for hyperthermia (41-45 degrees C) was extended from 5-6 mm (without cooling) to 11-19 mm with air-cooling (4.8 L min-1, airflow 10 degrees C), effectively doubling and tripling the thermal penetration in vivo. Similar improvements were demonstrated at higher temperatures with the thermal coagulation applicator. Biothermal simulations, which modeled the physical, thermal, and acoustic parameters of the air-cooled applicator and surrounding tissue, were also used to investigate potential improvements in heating patterns. The simulated radial heating profiles with transducer cooling demonstrated significantly enhanced thermal penetration over the experimental range of convective transfer, and also agreed with in vivo results. These theoretical and experimental results clearly show air-cooling controls the transducer surface temperature, significantly increases thermal penetration, and produces a greater treatment volume for direct-coupled US applicators in hyperthermia and thermal coagulation.

[1]  E L Madsen,et al.  Oil-in-gelatin dispersions for use as ultrasonically tissue-mimicking materials. , 1982, Ultrasound in medicine & biology.

[2]  R. Jain,et al.  Tumor Blood Flow-Characterization, Modifications, and Role in Hyperthermia , 1984, IEEE Transactions on Sonics and Ultrasonics.

[3]  R. Dickinson Thermal conduction errors of manganin-constantan thermocouple arrays , 1985 .

[4]  K. Hynynen,et al.  Temperature measurements during ultrasound hyperthermia. , 1989, Medical physics.

[5]  K. Hynynen,et al.  Induction of hyperthermia using an intracavitary multielement ultrasonic applicator , 1989, IEEE Transactions on Biomedical Engineering.

[6]  V. Eppert,et al.  Air cooling for an interstitial microwave hyperthermia antenna: theory and experiment , 1991, IEEE Transactions on Biomedical Engineering.

[7]  The effect of air cooling on the radial temperature distribution of a single microwave hyperthermia antenna in vivo. , 1991, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[8]  K Hynynen,et al.  The feasibility of interstitial ultrasound hyperthermia. , 1992, Medical physics.

[9]  K. Hynynen,et al.  Acoustic power calibrations of cylindrical intracavitary ultrasound hyperthermia applicators. , 1993, Medical physics.

[10]  K. Hynynen,et al.  Small cylindrical ultrasound sources for induction of hyperthermia via body cavities or interstitial implants. , 1993, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[11]  C. Diederich,et al.  Direct-coupled interstitial ultrasound applicators for simultaneous thermobrachytherapy: a feasibility study. , 1996, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[12]  C. Diederich Ultrasound applicators with integrated catheter-cooling for interstitial hyperthermia: theory and preliminary experiments. , 1996, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[13]  William H. Nau,et al.  Directional interstitial ultrasound applicators for thermal coagulation of tissue , 1998, Photonics West - Biomedical Optics.