Design Model for Confinement Reinforcement in Pretensioned Concrete I-Girders

The 2007 edition of AASHTO LRFD Bridge Design Specifications contains prescriptive requirements for the quantity and placement of confinement reinforcement located in the bottom bulb of pretensioned concrete I-girders. The proposed model can be used to design confinement reinforcement as an alternative to AASHTO's prescriptive requirements. The model considers a range of I-girder conditions and variations, yet is intended to be practical enough for use by bridge design engineers. Variables in the design model include flange and bearing geometry, strand size and placement, effective prestress force, concrete and steel material properties, and the effects of steel bearing plates. The model is based on strut-and-tie and shear-friction concepts and considers the lateral-splitting failure mode. Derivation of the model is presented, and the model is compared with experimental results from the published literature.

[1]  Brandon E. Ross Function and design of confinement reinforcement in pretensioned concrete I-girders , 2012 .

[2]  H. R. Hamilton,et al.  End Region Detailing of Pretensioned Concrete Bridge Girders , 2013 .

[3]  H. Hamilton,et al.  Shear Performance of Existing Prestressed Concrete Bridge Girders , 2009 .

[4]  Maher K. Tadros,et al.  Bottom Flange Reinforcement in NU I-Girders , 2010 .

[5]  Maher K. Tadros,et al.  Evaluation and Repair Procedures for Precast/Prestressed Concrete Girders with Longitudinal Cracking in the Web , 2010 .

[6]  Edwin G. Burdette,et al.  DEVELOPMENT LENGTH AND LATERAL SPACING REQUIREMENTS OF PRESTRESSING STRAND FOR PRESTRESSED CONCRETE BRIDGE GIRDERS , 1994 .

[7]  B E Ross,et al.  Load Testing of 30-year-old AASHTO Type III Highway Bridge Girders , 2011 .

[8]  H. R. Hamilton,et al.  Experimental and Analytical Evaluations of Confinement Reinforcement in Pretensioned Concrete Beams , 2011 .

[9]  R. Burgueño,et al.  Effects of Debonded Strands on the Production and Performance of Prestressed Concrete Beams , 2011 .

[10]  Olivier Burdet,et al.  ANCHORAGE ZONE REINFORCEMENT FOR POST-TENSIONED CONCRETE GIRDERS , 1994 .

[11]  Amin K Akhnoukh The Effect of Confinement on Transfer and Development Length of 0.7 Inch Prestressing Strands , 2010 .

[12]  Byung Hwan Oh,et al.  Theoretical Analysis of Transfer Lengths in Pretensioned Prestressed Concrete Members , 2006 .

[13]  Ned H. Burns,et al.  Measured transfer lengths of 0.5 and 0.6 in. strands in pretensioned concrete , 1996 .

[14]  Jack P. Moehle,et al.  "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE (ACI 318-11) AND COMMENTARY" , 2011 .