Evaluation of the Performances of Two Wearable Systems for Gait Analysis: A Pilot Study

Wearable sensor systems to perform human motion analysis are receiving increasing attention in different application fields. Among wearable sensors, inertial sensors have promising features. However, before they can be employed routinely in clinical applications, it is important to evaluate their reliability. Gait analysis was performed on one male volunteer: data were simultaneously collected with HGait System, based on magnetic and inertial measurement sensor units system, and with STEP32, a commercial electromechanical system already used in clinics. Spatio temporal parameters and joint kinematics in the sagittal plane obtained with H-Gait and STEP32 are compared. The MIMUs system provides a reliable estimation of spatiotemporal parameters, and acceptable hip and knee kinematic curves, while ankle joint measurements must be improved to be clinically useful.

[1]  Laura Gastaldi,et al.  A Combined Robotic and Cognitive Training for Locomotor Rehabilitation: Evidences of Cerebral Functional Reorganization in Two Chronic Traumatic Brain Injured Patients , 2011, Front. Hum. Neurosci..

[2]  Valentina Agostini,et al.  Segmentation and Classification of Gait Cycles , 2014, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[3]  Stefano Paolo Pastorelli,et al.  Indoor motion analysis of a subject wearing prosthesis for adaptive snowboarding , 2011 .

[4]  Valentina Agostini,et al.  Multiple gait patterns within the same Winters class in children with hemiplegic cerebral palsy. , 2015, Clinical biomechanics.

[5]  Valentina Agostini,et al.  REDUCTION OF GAIT ABNORMALITIES IN TYPE 2 DIABETIC PATIENTS DUE TO PHYSICAL ACTIVITY: A QUANTITATIVE EVALUATION BASED ON STATISTICAL GAIT ANALYSIS , 2012 .

[6]  Valentina Agostini,et al.  Does texting while walking really affect gait in young adults? , 2015, Journal of NeuroEngineering and Rehabilitation.

[7]  S. Õunpuu,et al.  Efficacy of clinical gait analysis: A systematic review. , 2011, Gait & posture.

[8]  L Simoncini,et al.  Muscle Performance About the Knee Joint in Patients Who Had Distal Femoral Replacement After Resection of a Bone Tumor: An Objective Study with Use of Gait Analysis* , 2000, The Journal of bone and joint surgery. American volume.

[9]  Xiaoping Yun,et al.  Design, Implementation, and Experimental Results of a Quaternion-Based Kalman Filter for Human Body Motion Tracking , 2006, IEEE Trans. Robotics.

[10]  Valentina Agostini,et al.  Instrumented gait analysis for an objective pre-/postassessment of tap test in normal pressure hydrocephalus. , 2015, Archives of physical medicine and rehabilitation.

[11]  Stefano Pastorelli,et al.  Accuracy evaluation of a new stereophotogrammetry-based functional method for joint kinematic analysis in biomechanics , 2014, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[12]  Maarit Kangas,et al.  Comparison of low-complexity fall detection algorithms for body attached accelerometers. , 2008, Gait & posture.

[13]  Tao Liu,et al.  Gait Analysis Using Wearable Sensors , 2012, Sensors.

[14]  M. Benedetti,et al.  Self-reported gait unsteadiness in mildly impaired neurological patients: an objective assessment through statistical gait analysis , 2012, Journal of NeuroEngineering and Rehabilitation.

[15]  Daniele Borzelli,et al.  Estimation of the CoM and CoP using a 3D body scanning systems: Validation with force plate: A case study , 2016, 2016 IEEE International Symposium on Medical Measurements and Applications (MeMeA).

[16]  S Pastorelli,et al.  Effects of botulinum neurotoxin on spatio-temporal gait parameters of patients with chronic stroke: a prospective open-label study. , 2015, European journal of physical and rehabilitation medicine.

[17]  Shyamal Patel,et al.  A review of wearable sensors and systems with application in rehabilitation , 2012, Journal of NeuroEngineering and Rehabilitation.

[18]  Laura Gastaldi,et al.  Application of a functional method for subject and motion specific joints kinematics during walking , 2016 .

[19]  Stefano Mauro,et al.  Feature-based estimation of space debris angular rate via compressed sensing and Kalman filtering , 2016, 2016 IEEE Metrology for Aerospace (MetroAeroSpace).

[20]  Peter H. Veltink,et al.  Ambulatory Position and Orientation Tracking Fusing Magnetic and Inertial Sensing , 2007, IEEE Transactions on Biomedical Engineering.

[21]  Aleksandar Milenkovic,et al.  Journal of Neuroengineering and Rehabilitation Open Access a Wireless Body Area Network of Intelligent Motion Sensors for Computer Assisted Physical Rehabilitation , 2005 .

[22]  K. Aminian,et al.  Physical activity monitoring based on accelerometry: validation and comparison with video observation , 1999, Medical & Biological Engineering & Computing.

[23]  Anita Sant'Anna,et al.  Assessment of Gait Symmetry and Gait Normality Using Inertial Sensors: In-Lab and In-Situ Evaluation , 2012, BIOSTEC.

[24]  Stefano Mauro,et al.  A geometric method for estimating space debris center of mass position and orbital parameters from features tracking , 2015, 2015 IEEE Metrology for Aerospace (MetroAeroSpace).

[25]  Stefano Pastorelli,et al.  A Biomechanical Approach to Paralympic Cross-Country Sit-Ski Racing , 2012, Clinical journal of sport medicine : official journal of the Canadian Academy of Sport Medicine.

[26]  Sandro Fioretti,et al.  Assessment of the variability of vastii myoelectric activity in young healthy females during walking: a statistical gait analysis. , 2015, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[27]  Massimo Sorli,et al.  Attitude recovery from feature tracking for estimating angular rate of non-cooperative spacecraft , 2017 .

[28]  Alfred D. Grant Gait Analysis: Normal and Pathological Function , 2010 .

[29]  Peter H Veltink,et al.  Accelerometer and rate gyroscope measurement of kinematics: an inexpensive alternative to optical motion analysis systems. , 2002, Journal of biomechanics.

[30]  Laura Gastaldi,et al.  Drift Removal for Improving the Accuracy of Gait Parameters Using Wearable Sensor Systems , 2014, Sensors.

[31]  B. G. Celler,et al.  Classification of basic daily movements using a triaxial accelerometer , 2004, Medical and Biological Engineering and Computing.

[32]  Stefano Pastorelli,et al.  Evaluation of functional methods for human movement modelling. , 2015, Acta of bioengineering and biomechanics.