Repeated invasive lung function measurements in intubated mice: an approach for longitudinal lung research

Invasive lung function measurements are useful tools to describe respiratory disease models in mice but only result in one time-point measurements because of tracheostomy. We explored if intubation may overcome the need for tracheostomy thereby allowing invasive lung function monitoring of individual mice over time. Repeated invasive lung function measurements with Scireq© – FlexiVent or Buxco© – Forced Pulmonary Maneuvers® were performed three times in BALB/c mice with intervals of 10 days. Each lung function assessment following intubation was compared with a similar measurement in age-matched tracheostomized mice, the golden standard in lung function measurements. Tracheostomy and intubation gave similar results for resistance, elastance and compliance of the whole respiratory system as assessed by Flexivent. Likewise, Forced Pulmonary Maneuvers used to measure lung volumes such as total lung capacity, functional residual capacity, forced expiratory volume in 0.1 s and forced vital capacity, resulted in identical outcomes for both airway approaches. No interaction was found between the procedures for any of the pulmonary function variables. The observed changes over time were rather related to animal growth than to repetitive intubation. Eighty percent of the animals survived three consecutive intubations, which were hampered by transient breathing difficulties, weight loss and neutrophilic bronchoalveolar lavage immediately postextubation. Repetitive invasive lung function measurements by intubation are feasible and reproducible in healthy mice and results are comparable to the standard method. This may open new perspectives for longitudinal research in animal models of respiratory diseases.

[1]  M. Decramer,et al.  Noninvasive and invasive pulmonary function in mouse models of obstructive and restrictive respiratory diseases. , 2010, American journal of respiratory cell and molecular biology.

[2]  E. Kidd,et al.  Establishing the phenotype in novel acute and chronic murine models of allergic asthma. , 2008, International immunopharmacology.

[3]  T. Nawrot,et al.  How long do the systemic and ventilatory responses to toluene diisocyanate persist in dermally sensitized mice? , 2008, The Journal of allergy and clinical immunology.

[4]  Wayne Mitzner,et al.  Invasive and noninvasive methods for studying pulmonary function in mice , 2007, Respiratory research.

[5]  H. Hoymann,et al.  Invasive and noninvasive lung function measurements in rodents. , 2007, Journal of pharmacological and toxicological methods.

[6]  H. Hoymann New developments in lung function measurements in rodents. , 2006, Experimental and toxicologic pathology : official journal of the Gesellschaft fur Toxikologische Pathologie.

[7]  N. Krug,et al.  Repetitive measurements of pulmonary mechanics to inhaled cholinergic challenge in spontaneously breathing mice. , 2004, Journal of applied physiology.

[8]  A. Adler,et al.  Unrestrained plethysmography is an unreliable measure of airway responsiveness in BALB/c and C57BL/6 mice. , 2004, Journal of applied physiology.

[9]  Jason H T Bates,et al.  Measuring lung function in mice: the phenotyping uncertainty principle. , 2003, Journal of applied physiology.

[10]  J. Bates,et al.  A reevaluation of the validity of unrestrained plethysmography in mice. , 2002, Journal of applied physiology.

[11]  C. Greeff,et al.  Shock-induced α–ω transition in titanium , 2001 .

[12]  Z Hantos,et al.  Hyperoxia-induced changes in mouse lung mechanics: forced oscillations vs. barometric plethysmography. , 2001, Journal of applied physiology.

[13]  R. Brown,et al.  A method of endotracheal intubation and pulmonary functional assessment for repeated studies in mice. , 1999, Journal of applied physiology.