Frequency‐domain simulation of MR tagging

Simulation of MR images is a useful tool for offline sequence development and as an aid to understanding image formation. One particular application of simulation is MR tagging, which is used for tracking myocardial motion. Simple spatial‐domain methods cannot adequately represent effects common in these images, such as motion artifact and signal wrap. An existing frequency‐domain model is shown to be inappropriate for tagged images, and an extension based on the Bloch equations and Fourier shift theorem is described to correct this. Software incorporating the new model is used to generate ideal tag intensity profiles and to accurately simulate tagged images. The shifted k‐space patterns associated with tagged images, and their dependence on the order of the binomial tagging sequence, are explained. An application of the Fourier shift theorem is suggested that allows more rapid simulation of static tagged images.

[1]  J S Petersson,et al.  MRI simulation using the k-space formalism. , 1993, Magnetic resonance imaging.

[2]  E. Zerhouni,et al.  Human heart: tagging with MR imaging--a method for noninvasive assessment of myocardial motion. , 1988, Radiology.

[3]  E. McVeigh MRI of myocardial function: motion tracking techniques. , 1996, Magnetic resonance imaging.

[4]  L. Axel,et al.  MR imaging of motion with spatial modulation of magnetization. , 1989, Radiology.

[5]  Jerry L. Prince,et al.  Tag and contour detection in tagged MR images of the left ventricle , 1994, IEEE Trans. Medical Imaging.

[6]  Elliot R. McVeigh,et al.  Optimization of tag thickness for measuring position with magnetic resonance imaging , 1994, IEEE Trans. Medical Imaging.

[7]  Richard R. Ernst,et al.  Diffusion and field‐gradient effects in NMR Fourier spectroscopy , 1974 .

[8]  R. Jeffrey,et al.  AIDS-related lymphomas: evaluation by abdominal CT. , 1986, Radiology.

[9]  C. Higgins,et al.  Role of MR imaging in acquired and congenital cardiovascular disease. , 1993, AJR. American journal of roentgenology.

[10]  E Berry,et al.  Simulation of two‐dimensional tagged MRI , 1997, Journal of magnetic resonance imaging : JMRI.

[11]  W. O'Dell,et al.  Three-dimensional myocardial deformations: calculation with displacement field fitting to tagged MR images. , 1995, Radiology.

[12]  E. McVeigh,et al.  Tag contrast in breath‐hold CINE cardiac MRI , 1994, Magnetic resonance in medicine.

[13]  E Tomei,et al.  Normal left ventricular dimensions and function: interstudy reproducibility of measurements with cine MR imaging. , 1990, Radiology.

[14]  L. Axel,et al.  Regional heart wall motion: two-dimensional analysis and functional imaging with MR imaging. , 1992, Radiology.

[15]  D. Woessner Effects of Diffusion in Nuclear Magnetic Resonance Spin-Echo Experiments , 1961 .