Clinical refinement of the automatic lung parameter estimator (ALPE)

The automatic lung parameter estimator (ALPE) method was developed in 2002 for bedside estimation of pulmonary gas exchange using step changes in inspired oxygen fraction (FiO2). Since then a number of studies have been conducted indicating the potential for clinical application and necessitating systems evolution to match clinical application. This paper describes and evaluates the evolution of the ALPE method from a research implementation (ALPE1) to two commercial implementations (ALPE2 and ALPE3). A need for dedicated implementations of the ALPE method was identified: one for spontaneously breathing (non-mechanically ventilated) patients (ALPE2) and one for mechanically ventilated patients (ALPE3). For these two implementations, design issues relating to usability and automation are described including the mixing of gasses to achieve FiO2 levels, and the automatic selection of FiO2. For ALPE2, these improvements are evaluated against patients studied using the system. The major result is the evolution of the ALPE method into two dedicated implementations, namely ALPE2 and ALPE3. For ALPE2, the usability and automation of FiO2 selection has been evaluated in spontaneously breathing patients showing that variability of gas delivery is 0.3 % (standard deviation) in 1,332 breaths from 20 patients. Also for ALPE2, the automated FiO2 selection method was successfully applied in 287 patient cases, taking 7.2 ± 2.4 min and was shown to be safe with only one patient having SpO2 < 86 % when the clinician disabled the alarms. The ALPE method has evolved into two practical, usable systems targeted at clinical application, namely ALPE2 for spontaneously breathing patients and ALPE3 for mechanically ventilated patients. These systems may promote the exploration of the use of more detailed descriptions of pulmonary gas exchange in clinical practice.

[1]  J. West,et al.  Ventilation-perfusion inequality in chronic obstructive pulmonary disease. , 1977, The Journal of clinical investigation.

[2]  H. Kehlet,et al.  Late postoperative nocturnal episodic hypoxaemia and associated sleep pattern. , 1994, British journal of anaesthesia.

[3]  S Andreassen,et al.  Reproduction of MIGET retention and excretion data using a simple mathematical model of gas exchange in lung damage caused by oleic acid infusion. , 2006, Journal of applied physiology.

[4]  Steen Andreassen,et al.  Non-invasive estimation of shunt and ventilation-perfusion mismatch , 2003, Intensive Care Medicine.

[5]  J B West,et al.  Measurement of continuous distributions of ventilation-perfusion ratios: theory. , 1974, Journal of applied physiology.

[6]  C. Mélot,et al.  Contribution of multiple inert gas elimination technique to pulmonary medicine. 5. Ventilation-perfusion relationships in acute respiratory failure. , 1994, Thorax.

[7]  S. Andreassen,et al.  Hypoxaemia after cardiac surgery: clinical application of a model of pulmonary gas exchange , 2004, European journal of anaesthesiology.

[8]  Göran Hedenstierna,et al.  Optimal Oxygen Concentration during Induction of General Anesthesia , 2003, Anesthesiology.

[9]  Steen Andreassen,et al.  The Automatic Lung Parameter Estimator (ALPE) System: Non-Invasive Estimation of Pulmonary Gas Exchange Parameters in 10-15 Minutes , 2004, Journal of Clinical Monitoring and Computing.

[10]  Steen Andreassen,et al.  Decision support of inspired oxygen selection based on Bayesian learning of pulmonary gas exchange parameters , 2005, Artif. Intell. Medicine.

[11]  R. Johnson Gas exchange efficiency in congestive heart failure II. , 2000, Circulation.

[12]  R. Johnson Gas exchange efficiency in congestive heart failure. , 2000, Circulation.

[13]  S. Andreassen,et al.  Modelling of hypoxaemia after gynaecological laparotomy , 2001, Acta anaesthesiologica Scandinavica.

[14]  Steen Andreassen,et al.  Minimal model quantification of pulmonary gas exchange in intensive care patients. , 2011, Medical engineering & physics.

[15]  Peter D Wagner,et al.  Assessment of gas exchange in lung disease: balancing accuracy against feasibility , 2007, Critical care.

[16]  Bram W. Smith,et al.  Using physiological models and decision theory for selecting appropriate ventilator settings , 2006, Journal of Clinical Monitoring and Computing.

[17]  R. Rodríguez-Roisín,et al.  Contribution of multiple inert gas elimination technique to pulmonary medicine , 1994 .

[18]  Steen Andreassen,et al.  Prospective evaluation of a decision support system for setting inspired oxygen in intensive care patients. , 2010, Journal of critical care.

[19]  V. Ranieri,et al.  Respiratory complications after major surgery , 2009, Current opinion in critical care.

[20]  Stephen E. Rees,et al.  Reproduction of inert gas and oxygenation data: a comparison of the MIGET and a simple model of pulmonary gas exchange , 2010, Intensive Care Medicine.

[21]  Steen Andreassen,et al.  Variation in the PaO2/FiO2 ratio with FiO2: mathematical and experimental description, and clinical relevance , 2007, Critical care.