Preparation of a skin equivalent phantom with interior micron-scale vessel structures for optical imaging experiments.

A popular alternative of preparing multilayer or microfluidic chip based phantoms could have helped to simulate the subsurface vascular network, but brought inevitable problems. In this work, we describe the preparation method of a single layer skin equivalent tissue phantom containing interior vessel channels, which mimick the superficial microvascular structure. The fabrication method does not disturb the optical properties of the turbiding matrix material. The diameter of the channels reaches a value of 50 μm. The size, as well as the geometry of the generated vessel structures are investigated by using the SD-OCT system. Our preliminary results confirm that fabrication of such a phantom is achievable and reproducible. Prospectively, this phantom is used to calibrate the optical angiographic imaging approaches.

[1]  D. Delpy,et al.  A design for a stable and reproducible phantom for use in near infra-red imaging and spectroscopy , 1993 .

[2]  Jessica C. Ramella-Roman,et al.  Microfluidics based phantoms of superficial vascular network , 2012, Biomedical optics express.

[3]  B. Wilson,et al.  A diffusion theory model of spatially resolved, steady-state diffuse reflectance for the noninvasive determination of tissue optical properties in vivo. , 1992, Medical physics.

[4]  Jianting Wang,et al.  Three-dimensional printing of tissue phantoms for biophotonic imaging. , 2014, Optics letters.

[5]  Valery V. Tuchin,et al.  OPTICAL PROPERTIES OF SKIN, SUBCUTANEOUS, AND MUSCLE TISSUES: A REVIEW , 2011 .

[6]  Kelsey M. Kennedy,et al.  Review of tissue simulating phantoms with controllable optical, mechanical and structural properties for use in optical coherence tomography , 2012, Biomedical optics express.

[7]  Jeremy C Hebden,et al.  A tissue equivalent phantom for simultaneous near-infrared optical tomography and EEG , 2010, Biomedical optics express.

[8]  Bruce J. Tromberg,et al.  Tissue phantoms in multicenter clinical trials for diffuse optical technologies , 2012, Biomedical optics express.

[9]  A. P. Popov,et al.  Skin phantoms with realistic vessel structure for OCT measurements , 2010, Laser Applications in Life Sciences.

[10]  R Marchesini,et al.  A phantom with tissue‐like optical properties in the visible and near infrared for use in photomedicine , 2001, Lasers in surgery and medicine.

[11]  A Fenster,et al.  A real vessel phantom for imaging experimentation. , 1997, Medical physics.

[12]  A F van der Steen,et al.  Elastic and Acoustic Properties of Vessel Mimicking Material for Elasticity Imaging , 1997, Ultrasonic imaging.

[13]  A. Welch,et al.  Determining the optical properties of turbid mediaby using the adding-doubling method. , 1993, Applied optics.

[14]  S. Prahl,et al.  Optical properties of scattering and absorbing materials used in the development of optical phantoms at 1064 nm. , 1996, Journal of biomedical optics.

[15]  Jean-Pierre Ballini,et al.  Correlation of photodynamic activity and fluorescence signaling for free and pegylated mTHPC in mesothelioma xenografts , 2007, Lasers in surgery and medicine.

[16]  Z Petrovich,et al.  Utilization of a multilayer polyacrylamide phantom for evaluation of hyperthermia applicators. , 1992, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[17]  Alexander V. Priezzhev,et al.  Multilayer tissue phantoms with embedded capillary system for OCT and DOCT imaging , 2011, European Conference on Biomedical Optics.

[18]  V. V. Tuchin,et al.  Finger tissue model and blood perfused skin tissue phantom , 2011, BiOS.

[19]  B. Pogue,et al.  Review of tissue simulating phantoms for optical spectroscopy, imaging and dosimetry. , 2006, Journal of biomedical optics.

[20]  Rolf B. Saager,et al.  Multilayer silicone phantoms for the evaluation of quantitative optical techniques in skin imaging , 2010, BiOS.

[21]  M S Patterson,et al.  The use of India ink as an optical absorber in tissue-simulating phantoms , 1992, Physics in medicine and biology.