In vivo study of partial liver resection on pigs using a 1.9 μm thulium fiber laser

Dissection of liver tissue can be performed by different techniques (ultrasound, mono and bipolar dissection, water jet dissection and by stapler). In this animal study the potential of a Thulium fiber laser system was investigated for open parenchyma dissection. Based on a cw Thulium fiber laser (IPG laser GmbH, Burbach, Germany), emitting a wavelength at 1.9 μm and a maximal power at 50 W, a surgical dissection device was developed at the Medical Laser Centre Luebeck. Cw laser radiation (40 Watt) was transmitted via a 365 μm fiber with a polished distal fiber tip. Procedure was performed in contact mode; irradiance at the distal fiber tip was 38.2 kW/cm2. After general anesthesia and a median laparotomy an atypical laser resection of the liver was performed in 3 pigs. Healing process was controlled after 2-3 weeks by histological analysis (H&E staining). The final evaluation data included total resection time, blood loss, bile leakage and mass of dissected tissue. All animals treated in this study were cared for in accordance to the European convention on animal care. In general the dissection with the 1.9 μm laser radiation was easily performed. Hemostasis was highly sufficient so blood loss and bile leakage was negligible. Total resection time including hemostasis of the remaining tissue was 26 ± 12 min. Weight of resected tissue was 17 ± 8 g. During survival period no complications (bleeding or inflammation) occurred. After 2 weeks histology showed ongoing scar formation about 1 - 2 mm in depth of the dissected area.

[1]  Sebastian Wenk,et al.  Design and Technical Concept of a Tm Laser Scalpel for Clinical Investigation Based on a 60W, 1.92 µm Tm Fiber Laser System , 2007 .

[2]  D. Theisen-Kunde,et al.  Comparison between a 1.92-μm fiber laser and a standard HF-dissection device for nephron-sparing kidney resection in a porcine in vivo study , 2011, Lasers in Medical Science.

[3]  E. F. Maher,et al.  Transmission and Absorption Coefficients for Ocular Media of the Rhesus Monkey , 1978 .

[4]  Nathaniel M Fried,et al.  Thulium fiber laser lithotripsy: An in vitro analysis of stone fragmentation using a modulated 110‐watt Thulium fiber laser at 1.94 µm , 2005, Lasers in surgery and medicine.

[5]  Jian Zhuo,et al.  Thulium laser versus standard transurethral resection of the prostate: a randomized prospective trial. , 2008, European urology.

[6]  P. Froehlich,et al.  Thulium laser in airway diseases in children , 2008, Current opinion in otolaryngology & head and neck surgery.

[7]  Richard L. Blackmon,et al.  Holmium:YAG (λ = 2,120 nm) versus thulium fiber (λ = 1,908 nm) laser lithotripsy , 2010, Lasers in surgery and medicine.

[8]  Stefano Mattioli,et al.  [What does Revolix laser contribute to partial nephrectomy?]. , 2008, Archivos espanoles de urologia.

[9]  Nathaniel M. Fried,et al.  Thulium fiber laser lithotripsy , 2009, BiOS.

[10]  R. Brinkmann,et al.  Temperature dependence of water absorption for wavelengths at 1920 nm and 1940 nm , 2009 .

[11]  Jörg Schubert,et al.  Laser-supported partial nephrectomy for renal cell carcinoma. , 2008, Urology.