Calculation of the uncertainty in complication probability for various dose-response models, applied to the parotid gland.

PURPOSE Usually, models that predict normal tissue complication probability (NTCP) are fitted to clinical data with the maximum likelihood (ML) method. This method inevitably causes a loss of information contained in the data. In this study, an alternative method is investigated that calculates the parameter probability distribution (PD), and, thus, conserves all information. The PD method also allows the calculation of the uncertainty in the NTCP, which is an (often-neglected) prerequisite for the intercomparison of both treatment plans and NTCP models. The PD and ML methods are applied to parotid gland data, and the results are compared. METHODS AND MATERIALS The drop in salivary flow due to radiotherapy was measured in 25 parotid glands of 15 patients. Together with the parotid gland dose-volume histograms (DVH), this enabled the calculation of the parameter PDs for three different NTCP models (Lyman, relative seriality, and critical volume). From these PDs, the NTCP and its uncertainty could be calculated for arbitrary parotid gland DVHs. ML parameters and resulting NTCP values were calculated also. RESULTS All models fitted equally well. The parameter PDs turned out to have nonnormal shapes and long tails. The NTCP predictions of the ML and PD method usually differed considerably, depending on the NTCP model and the nature of irradiation. NTCP curves and ML parameters suggested a highly parallel organization of the parotid gland. CONCLUSIONS Considering the substantial differences between the NTCP predictions of the ML and PD method, the use of the PD method is preferred, because this is the only method that takes all information contained in the clinical data into account. Furthermore, PD method gives a true measure of the uncertainty in the NTCP.

[1]  Practical considerations in using calculated healthy-tissue complication probabilities for treatment-plan optimization. , 1999, International journal of radiation oncology, biology, physics.

[2]  R K Ten Haken,et al.  Dose, volume, and function relationships in parotid salivary glands following conformal and intensity-modulated irradiation of head and neck cancer. , 1999, International journal of radiation oncology, biology, physics.

[3]  A. Brahme,et al.  An adaptive control algorithm for optimization of intensity modulated radiotherapy considering uncertainties in beam profiles, patient set-up and internal organ motion. , 1998, Physics in medicine and biology.

[4]  S. Söderström,et al.  Aspects on the optimal photon beam energy for radiation therapy. , 1999, Acta oncologica.

[5]  J. Cooper,et al.  Late effects of radiation therapy in the head and neck region. , 1995, International journal of radiation oncology, biology, physics.

[6]  James B. Smathers,et al.  Biologically effective dose distribution based on the linear quadratic model and its clinical relevance , 1995 .

[7]  C E Metz,et al.  Maximum likelihood estimation of dose-response parameters for therapeutic operating characteristic (TOC) analysis of carcinoma of the nasopharynx. , 1982, International journal of radiation oncology, biology, physics.

[8]  G. Hanks Conformal radiotherapy for prostate cancer , 2000, Annals of medicine.

[9]  G J Kutcher,et al.  Probability of radiation-induced complications in normal tissues with parallel architecture under conditions of uniform whole or partial organ irradiation. , 1993, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[10]  A. Vissink,et al.  The efficacy of mucin-containing artificial saliva in alleviating symptoms of xerostomia. , 1987, Gerodontology.

[11]  Ronald Fante Signal Analysis and Estimation , 1988 .

[12]  A J Lomax,et al.  A treatment planning inter-comparison of proton and intensity modulated photon radiotherapy. , 1999, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[13]  D P Dearnaley,et al.  A comparison of coplanar four-field techniques for conformal radiotherapy of the prostate. , 1999, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[14]  M. Joiner,et al.  Renal damage in the mouse: the response to very small doses per fraction. , 1988, Radiation research.

[15]  B. Sonies,et al.  Xerostomia: evaluation of a symptom with increasing significance. , 1985, Journal of the American Dental Association.

[16]  G J Kutcher,et al.  Probability of radiation-induced complications for normal tissues with parallel architecture subject to non-uniform irradiation. , 1993, Medical physics.

[17]  C. King,et al.  Optimal radiotherapy for prostate cancer: predictions for conventional external beam, IMRT, and brachytherapy from radiobiologic models. , 2000, International journal of radiation oncology, biology, physics.

[18]  J. Lyman Complication Probability as Assessed from Dose-Volume Histograms , 1985 .

[19]  T Bortfeld,et al.  Optimized planning using physical objectives and constraints. , 1999, Seminars in radiation oncology.

[20]  A Brahme,et al.  Tumour and normal tissue responses to fractionated non-uniform dose delivery. , 1992, International journal of radiation biology.

[21]  A Brahme,et al.  Optimization of uncomplicated control for head and neck tumors. , 1990, International journal of radiation oncology, biology, physics.

[22]  C. Burman,et al.  Calculation of complication probability factors for non-uniform normal tissue irradiation: the effective volume method. , 1989, International journal of radiation oncology, biology, physics.

[23]  A. Niemierko,et al.  Optimization of 3D radiation therapy with both physical and biological end points and constraints. , 1992, International journal of radiation oncology, biology, physics.

[24]  A. Brahme,et al.  Optimized radiation therapy based on radiobiological objectives. , 1999, Seminars in radiation oncology.

[25]  A. Brahme,et al.  Optimal radiation beam profiles considering uncertainties in beam patient alignment. , 1993, Acta oncologica.

[26]  A Brahme,et al.  Optimization of the dose delivery in a few field techniques using radiobiological objective functions. , 1993, Medical physics.

[27]  G J Kutcher,et al.  Analysis of clinical complication data for radiation hepatitis using a parallel architecture model. , 1995, International journal of radiation oncology, biology, physics.

[28]  William H. Press,et al.  Numerical recipes in C , 2002 .

[29]  Beam characteristics and clinical possibilities of a new compact treatment unit design combining narrow pencil beam scanning and segmental multileaf collimation. , 1998, Medical physics.

[30]  A Ottolenghi,et al.  Radiation pneumonitis after breast cancer irradiation: analysis of the complication probability using the relative seriality model. , 2000, International journal of radiation oncology, biology, physics.

[31]  M. Goitein,et al.  Fitting of normal tissue tolerance data to an analytic function. , 1991, International journal of radiation oncology, biology, physics.

[32]  William H. Press,et al.  Numerical Recipes in C, 2nd Edition , 1992 .

[33]  D. Brenner,et al.  Investigation of hypersensitivity to fractionated low-dose radiation exposure. , 1999, International journal of radiation oncology, biology, physics.

[34]  H. Withers,et al.  Treatment volume and tissue tolerance. , 1988, International journal of radiation oncology, biology, physics.

[35]  U. Isacsson,et al.  Comparative treatment planning between proton and x-ray therapy in esophageal cancer. , 1998, International journal of radiation oncology, biology, physics.

[36]  U Isacsson,et al.  Potential advantages of protons over conventional radiation beams for paraspinal tumours. , 1997, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[37]  M. Goitein,et al.  Tolerance of normal tissue to therapeutic irradiation. , 1991, International journal of radiation oncology, biology, physics.

[38]  A. Niemierko,et al.  Modeling of normal tissue response to radiation: the critical volume model. , 1993, International journal of radiation oncology, biology, physics.

[39]  S M Bentzen,et al.  Quantifying the position and steepness of radiation dose-response curves. , 1997, International journal of radiation biology.