Field studies on thermal comfort of air-conditioned and non air-conditioned buildings in Malaysia

Field studies on the environmental conditions and occupant comfort were carried out in air-conditioned buildings and non air-conditioned buildings in Malaysia. The study on the air-conditioned buildings was carried out in UNITEN and for the non air-conditioned buildings in two schools, which is a primary and secondary school, and in a public waiting area in a health clinic in Johor Bahru, located in the southern region of Malaysia. The non air-conditioned buildings were mechanically ventilated by fans. The studies were made in different days from morning until noon as to get variation of temperatures, collecting a full set of objective physical measurements and subjective assessments through questionnaires. The measured environmental parameters were air temperature, relative humidity and air velocity. The subjective responses concern the judgment of the respondents about the thermal environment at the moment of measurements. The results obtained showed that majority of the respondents found that their indoor thermal conditions acceptable even though most of the thermal sensation votes (TSV) exceeded those specified by ASHRAE Standard 55 and the environmental assessments exceeded the standard. The neutral temperature and comfort range were obtained through linear regression analysis of TSV and in the Fanger's PMV model. From the subjective assessment, it was found that the occupants can accept the thermal range beyond the ASHRAE comfort zone. The neutral temperature of 24.4°C and 28.4°C for air-conditioned and non air-conditioned buildings respectively, were obtained by regression analysis of TSV on operative temperature. The acceptable range of temperature obtained by regression analysis of TSV were 23.1°C to 25.6°C for air-conditioned buildings and 26.0°C to 30.7°C for non air-conditioned buildings.

[1]  P. O. Fanger,et al.  Thermal comfort: analysis and applications in environmental engineering, , 1972 .

[2]  C. G. Webb An Analysis of Some Observations of Thermal Comfort in an Equatorial Climate , 1959, British journal of industrial medicine.

[3]  K. E. Charles Fanger ’ s Thermal Comfort and Draught Models Fanger ’ s Thermal Comfort and Draught Models , 2004 .

[4]  Bjarne W. Olesen Guidelines for Comfort , 2000 .

[5]  Michael A. Humphreys,et al.  ADAPTIVE THERMAL COMFORT AND SUSTAINABLE THERMAL STANDARDS FOR BUILDINGS , 2002 .

[6]  J. F. Nicol,et al.  Climatic variations in comfortable temperatures: the Pakistan projects , 1999 .

[7]  Adrian Pitts,et al.  An investigation of the thermal comfort adaptive model in a tropical upland climate , 1998 .

[8]  Ibrahim Hussein,et al.  Field study on thermal comfort in Malaysia , 2009 .

[9]  F. P. Ellis,et al.  Thermal comfort in warm, humid atmospheres Observations in a warship in the tropics , 1952, Journal of Hygiene.

[10]  Ellis Fp,et al.  Thermal comfort in warm, humid atmospheres; observations in a warship in the tropics. , 1952 .

[11]  R. J. Dear,et al.  Thermal comfort in the humid tropics. Part I. Climate chamber experiments on temperature preferences in Singapore , 1991 .

[12]  F. Nicol Adaptive thermal comfort standards in the hot–humid tropics , 2004 .

[13]  P. Fanger Moderate Thermal Environments Determination of the PMV and PPD Indices and Specification of the Conditions for Thermal Comfort , 1984 .

[14]  R. J. Dear,et al.  Thermal comfort in the humid tropics: Field experiments in air conditioned and naturally ventilated buildings in Singapore , 1991 .

[15]  D. J. Harris,et al.  Thermal comfort in sub-Saharan Africa : Field study report in Jos-Nigeria , 2008 .

[16]  Nyuk Hien Wong,et al.  Thermal comfort in classrooms in the tropics , 2003 .