A Comparative Study on the Suitability of Smartphones and IMU for Mobile, Unsupervised Energy Expenditure Calculi

The metabolic equivalent of task (MET) is currently the most used indicator for measuring the energy expenditure (EE) of a physical activity (PA) and has become an important measure for determining and supervising a person’s state of health. The use of new devices which are capable of measuring inertial movements by means of built-in accelerometers enable the PA to be measured objectively on the basis of the reckoning of “counts”. These devices are also known as inertial measurement units (IMUs) and each count is an aggregated value indicating the intensity of a movement and can be used in conjunction with other parameters to determine the MET rate of a particular physical activity and thus it’s associated EE. Various types of inertial devices currently exist that enable count calculus and physical activity to be monitored. The advent of mobile devices, such as smartphones, with empowered computation capabilities and integrated inertial sensors, has enabled EE to be measure in a distributed, ubiquitous and natural way, thereby overcoming the reluctance of users and practitioners associated with in-lab studies. From the point of view of the process analysis and infrastructure needed to manage data from inertial devices, there are also various differences in count computing: extra devices are required, out-of-device processing, etc. This paper presents a study to discover whether the estimation of energy expenditure is dependent on the accelerometer of the device used in measurements and to discover the suitability of each device for performing certain physical activities. In order to achieve this objective, we have conducted several experiments with different subjects on the basis of the performance of various daily activities with different smartphones and IMUs.

[1]  I-Min Lee,et al.  Using accelerometers to measure physical activity in large-scale epidemiological studies: issues and challenges , 2013, British Journal of Sports Medicine.

[2]  Manuel Noguera,et al.  Energy Expenditure Analysis: A Comparative Research of Based on Mobile Accelerometers , 2014, IWAAL.

[3]  A. Goris,et al.  Detection of type, duration, and intensity of physical activity using an accelerometer. , 2009, Medicine and science in sports and exercise.

[4]  Susan L Murphy,et al.  Review of physical activity measurement using accelerometers in older adults: considerations for research design and conduct. , 2009, Preventive medicine.

[5]  Usdhhs Physical Activity and Health: A Report of the Surgeon General , 1996 .

[6]  José Luis Garrido,et al.  Zappa: An Open Mobile Platform to Build Cloud-Based m-Health Systems , 2013, ISAmI.

[7]  T. Strandberg,et al.  Frailty in elderly people , 2007, The Lancet.

[8]  D. Bassett,et al.  The technology of accelerometry-based activity monitors: current and future. , 2005, Medicine and science in sports and exercise.

[9]  D. Calloway,et al.  Energy requirements and energy expenditure of elderly men. , 1980, The American journal of clinical nutrition.

[10]  J. Sallis Measuring Physical Activity and Energy Expenditure , 1996 .

[11]  Yeh-Liang Hsu,et al.  A Review of Accelerometry-Based Wearable Motion Detectors for Physical Activity Monitoring , 2010, Sensors.

[12]  Wim H. M. Saris,et al.  Measuring Physical Activity and Energy Expenditure , 1996 .

[13]  Søren Brage,et al.  A method to compare new and traditional accelerometry data in physical activity monitoring , 2010, 2010 IEEE International Symposium on "A World of Wireless, Mobile and Multimedia Networks" (WoWMoM).

[14]  A C Pinheiro Volp,et al.  Energy expenditure: components and evaluation methods. , 2011, Nutricion hospitalaria.

[15]  Yves Schutz,et al.  Metabolic equivalent: one size does not fit all. , 2005, Journal of applied physiology.

[16]  G. Cardon,et al.  Actigraph GT3X: Validation and Determination of Physical Activity Intensity Cut Points , 2013, International Journal of Sports Medicine.

[17]  John Nelson,et al.  Embedded fall and activity monitoring for a wearable ambient assisted living solution for older adults , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[18]  M. Goran,et al.  Endurance training does not enhance total energy expenditure in healthy elderly persons. , 1992, The American journal of physiology.

[19]  N Garatachea,et al.  Physical activity and energy expenditure measurements using accelerometers in older adults. , 2010, Nutricion hospitalaria.

[20]  S. Intille,et al.  Estimating activity and sedentary behavior from an accelerometer on the hip or wrist. , 2013, Medicine and science in sports and exercise.

[21]  Rodney B. Murray,et al.  Area under a Curve: Trapezoidal and Simpson’s Rules , 1987 .

[22]  John Staudenmayer,et al.  Evaluation of artificial neural network algorithms for predicting METs and activity type from accelerometer data: validation on an independent sample. , 2011, Journal of applied physiology.

[23]  U. Ekelund,et al.  Comparison of two methods of measuring physical activity in South African older adults. , 2006, Journal of aging and physical activity.

[24]  B E Ainsworth,et al.  Compendium of physical activities: an update of activity codes and MET intensities. , 2000, Medicine and science in sports and exercise.

[25]  Merryn J Mathie,et al.  Accelerometry: providing an integrated, practical method for long-term, ambulatory monitoring of human movement , 2004, Physiological measurement.

[26]  Stephen S. Intille,et al.  Using wearable activity type detection to improve physical activity energy expenditure estimation , 2010, UbiComp.

[27]  M. Jetté,et al.  Metabolic equivalents (METS) in exercise testing, exercise prescription, and evaluation of functional capacity , 1990, Clinical cardiology.

[28]  Y. Oshima,et al.  Classifying household and locomotive activities using a triaxial accelerometer. , 2010, Gait & posture.

[29]  A. Stewart,et al.  CHAMPS physical activity questionnaire for older adults: outcomes for interventions. , 2001, Medicine and science in sports and exercise.

[30]  Scott E Crouter,et al.  A novel method for using accelerometer data to predict energy expenditure. , 2006, Journal of applied physiology.