New, Virtually Wall-Less Cannulas Designed for Augmented Venous Drainage in Minimally Invasive Cardiac Surgery

Objective Inadequate venous drainage during minimally invasive cardiac surgery becomes most evident when the blood trapped in the pulmonary circulation floods the surgical field. The present study was designed to assess the in vivo performance of new, thinner, virtually wall-less, venous cannulas designed for augmented venous drainage in comparison to traditional thin-wall cannulas. Methods Remote cannulation was realized in 5 bovine experiments (74.0 ± 2.4 kg) with percutaneous venous access over the wire, serial dilation up to 18 F and insertion of either traditional 19 F thin wall, wire-wound cannulas, or through the same access channel, new, thinner, virtually wall-less, braided cannulas designed for augmented venous drainage. A standard minimal extracorporeal circuit set with a centrifugal pump and a hollow fiber membrane oxygenator, but no inline reservoir was used. One hundred fifty pairs of pump-flow and required pump inlet pressure values were recorded with calibrated pressure transducers and a flowmeter calibrated by a volumetric tank and timer at increasing pump speed from 1500 RPM to 3500 RPM (500-RPM increments). Results Pump flow accounted for 1.73 ± 0.85 l/min for wall-less versus 1.17 ± 0.45 l/min for thin wall at 1500 RPM, 3.91 ± 0.86 versus 3.23 ± 0.66 at 2500 RPM, 5.82 ± 1.05 versus 4.96 ± 0.81 at 3500 RPM. Pump inlet pressure accounted for 9.6 ± 9.7 mm Hg versus 4.2 ± 18.8 mm Hg for 1500 RPM, −42.4 ± 26.7 versus −123 ± 51.1 at 2500 RPM, and −126.7 ± 55.3 versus −313 ±116.7 for 3500 RPM. Conclusions At the well-accepted pump inlet pressure of −80 mm Hg, the new, thinner, virtually wall-less, braided cannulas provide unmatched venous drainage in vivo. Early clinical analyses have confirmed these findings.

[1]  G. Pradas,et al.  Use of self-expanding venous cannula in tricuspid reoperation. , 2015, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[2]  L. V. von Segesser,et al.  How to prevent venous cannula orifice obstruction during extracorporeal circulation , 2015, Perfusion.

[3]  D. Berdajs,et al.  Venous cannula performance assessment in a realistic caval tree model. , 2015, Interactive cardiovascular and thoracic surgery.

[4]  D. Berdajs,et al.  Caval collapse during cardiopulmonary bypass: a reproducible bench model. , 2014, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[5]  L. V. von Segesser,et al.  Performance Increase in Venous Drainage for Mini-Invasive Heart Surgery: Superiority of Self-Expanding Cannulas , 2014, Innovations.

[6]  D. Berdajs,et al.  The new advanced membrane gas exchanger. , 2011, Interactive cardiovascular and thoracic surgery.

[7]  L. V. von Segesser,et al.  Temporary caval stenting improves venous drainage during cardiopulmonary bypass. , 2008, Interactive cardiovascular and thoracic surgery.

[8]  L. V. von Segesser,et al.  Routine use of self-expanding venous cannulas for cardiopulmonary bypass: benefits and pitfalls in 100 consecutive cases. , 2008, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[9]  D. Loisance,et al.  Kinetic assisted venous drainage for orthotopic heart transplantation in patients under mechanical circulatory support: a double-edged sword. , 2008, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[10]  D. Holt,et al.  Can vacuum assisted venous drainage be achieved using a roller pump in an emergency? A pilot study using neonatal circuitry. , 2007, The journal of extra-corporeal technology.

[11]  L. V. von Segesser,et al.  Using computational fluid dynamics to evaluate a novel venous cannula (Smart canula ®) for use in cardiopulmonary bypass operating procedures , 2007, Perfusion.

[12]  O. Alfieri,et al.  Vacuum-assisted venous drainage in extrathoracic cardiopulmonary bypass management during minimally invasive cardiac surgery , 2006, Perfusion.

[13]  L. Segesser Peripheral cannulation for cardiopulmonary bypass , 2006 .

[14]  L. V. von Segesser,et al.  The Smartcanula: a new tool for remote access perfusion in limited access cardiac surgery. , 2005, The heart surgery forum.

[15]  D. Stump,et al.  Does vacuum-assisted venous drainage increase gaseous microemboli during cardiopulmonary bypass? , 2002, The Annals of thoracic surgery.

[16]  L. V. von Segesser,et al.  In situ introducer sheath dilatation for complex aortic access. , 2002, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[17]  L. V. von Segesser,et al.  A new concept of integrated cardiopulmonary bypass circuit. , 2002, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[18]  L. V. von Segesser,et al.  Venous drainage with a single peripheral bicaval cannula for less invasive atrial septal defect repair. , 2001, The Annals of thoracic surgery.

[19]  A. Galloway,et al.  Assisted venous drainage presents the risk of undetected air microembolism. , 2000, The Journal of thoracic and cardiovascular surgery.

[20]  L. V. von Segesser,et al.  Augmented venous return for minimally invasive open heart surgery with selective caval cannulation. , 1999, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[21]  L. Segesser Cardiopulmonary support and extracorporeal membrane oxygenation for cardiac assist , 1999 .

[22]  L. V. von Segesser Cardiopulmonary support and extracorporeal membrane oxygenation for cardiac assist. , 1999, The Annals of thoracic surgery.

[23]  B. J. Rice,et al.  Assisted venous drainage, venous air, and gaseous microemboli transmission into the arterial line: an in-vitro study. , 1998, The journal of extra-corporeal technology.

[24]  M. Tönz,et al.  [Are the advantages of percutaneous catheterization technique gained by increased blood trauma?]. , 1993, Helvetica chirurgica acta.

[25]  J. Bavaria,et al.  Flow dynamics of peripheral venous catheters during extracorporeal membrane oxygenation with a centrifugal pump. , 1988, The Journal of thoracic and cardiovascular surgery.