Upgrading of tall oil to fuels and chemicals over HZSM-5 catalyst using various diluents

The upgrading of crude tall oil (CTO) to fuels and chemicals was studied at atmospheric pressure and in the temperature range 370 to 440°C in a fixed bed microreactor containing HZSM-5. The oil was co-fed with diluents such as tetralin, methanol and steam. High oil conversions of the order of 80–90 wt. % were obtained using tetralin and methanol as diluents but with steam the conversion only ranged between 36 to 70 wt. %. The maximum concentration of gasoline range aromatic hydrocarbons in the liquid product was 52 and 57 wt. % with tetralin and steam but only 39 wt. % with methanol. The amount of gas product in most of the runs was 1–4 wt.%. A reaction scheme is postulated based on the results. On a etudie la valorisation du tall oil pur (CTO) en produits combustibles et chimiques a la pression atmospherique et dans une gamme de temperatures de 370 a 440°C dans un micro-reamp;icteur a lit fixe contenant une HZSM-5. L'huile a ete co-alimentee avec des diluants comme la tetraline, le methanol et la vapeur. On a obtenu des conversions eleves de l'huile de l'ordre de 80 a 90% en poids en utilisant la tetraline et le methanol comme diulants, mais avec la vapeur la conversion se situe seulement entre 36 et 70% en poids. La concentration maximum en hydrocarbures aromatiques de la gamme de l'essence dans le produit liquide est de 52 et de 57% en poids avec la tetraline et la vapeur mais seulement de 39% en poids avec le methanol. Le quantite de produit gazeux dans la plupart des essais est de 1 a 4% en poids. On presente un schema de reaction en nous appuyant sur les resultats.