Cardiac induced localised motion of the human torso detected by a long period grating fibre optic sensing scheme

Cardiovascular health of the human population is a major concern for medical clinicians, with cardiovascular diseases responsible for 48% of all deaths worldwide, according to the World Health Organisation. Therefore the development of new practicable and economical diagnostic tools to scrutinise the cardiovascular health of humans is a major driver for clinicians. We offer a new technique to obtain seismocardiographic signals covering both ballistocardiography (below 20Hz) and audible heart sounds (20Hz upwards). The detection scheme is based upon an array of curvature/displacement sensors using fibre optic long period gratings interrogated using a variation of the derivative spectroscopy interrogation technique.

[1]  Zhihao Chen,et al.  Portable fiber optic ballistocardiogram sensor for home use , 2012, Other Conferences.

[2]  Lin Zhang,et al.  Uv-written in-fibre Bragg gratings , 1996 .

[3]  Ian Bennion,et al.  Respiratory function monitoring using a real-time three-dimensional fiber-optic shaping sensing scheme based upon fiber Bragg gratings , 2012, Journal of biomedical optics.

[4]  P. Öberg,et al.  Monitoring of respiratory and heart rates using a fibre-optic sensor , 1992, Medical and Biological Engineering and Computing.

[5]  T Allsop,et al.  Arbitrary real-time three-dimensional corporal object sensing and reconstruction scheme. , 2012, Optics letters.

[6]  David J. Webb,et al.  A comparison of the sensing characteristics of long period gratings written in three different types of fiber , 2003 .

[7]  Daming Wei,et al.  Real-Time Monitoring of Respiration Rhythm and Pulse Rate During Sleep , 2006, IEEE Transactions on Biomedical Engineering.

[8]  A. Akhbardeh,et al.  An EMFi-film sensor based ballistocardiographic chair: performance and cycle extraction method , 2005, IEEE Workshop on Signal Processing Systems Design and Implementation, 2005..

[9]  Alan D. Kersey,et al.  Shape and vibration mode sensing using a fiber optic Bragg grating array , 1996 .

[10]  J. Siivola,et al.  New noninvasive piezoelectric transducer for recording of respiration, heart rate and body movements , 1989, Medical and Biological Engineering and Computing.

[11]  B. J. Kirby,et al.  Clinical examination of the heart , 2002 .

[12]  Sergei A. Vasiliev,et al.  Long-period refractive index fiber gratings: properties, applications, and fabrication techniques , 2000, Other Conferences.

[13]  M. Tavel,et al.  Spectral analysis of heart sounds: relationships between some physical characteristics and frequency spectra of first and second heart sounds in normals and hypertensives. , 1984, Journal of biomedical engineering.

[14]  R. S. Anand PC based monitoring of human heart sounds , 2005, Comput. Electr. Eng..

[15]  David J. Webb,et al.  Surface plasmon resonance generation utilising gratings for biochemical sensing , 2006 .

[16]  P. Rahko,et al.  Evaluation of the skin-to-heart distance in the standing adult by two-dimensional echocardiography. , 2008, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[17]  Hershel Raff,et al.  Human Physiology: The Mechanisms of Body Function , 2006 .

[18]  Richard M. Wiard,et al.  Robust ballistocardiogram acquisition for home monitoring , 2009, Physiological measurement.

[19]  Ian Bennion,et al.  A strain sensing system using a novel optical fibre Bragg grating sensor and a synthetic heterodyne interrogation technique , 2002 .

[20]  J. Vagedes,et al.  How accurate is pulse rate variability as an estimate of heart rate variability? A review on studies comparing photoplethysmographic technology with an electrocardiogram. , 2013, International journal of cardiology.

[21]  D. S. Luciano,et al.  Human Physiology: The Mechanism of Body Function , 1975 .

[22]  James T. Patrie,et al.  Development and Preliminary Validation of Heart Rate and Breathing Rate Detection Using a Passive, Ballistocardiography-Based Sleep Monitoring System , 2009, IEEE Transactions on Information Technology in Biomedicine.

[23]  Hypolito José Kalinowski,et al.  A fibre optic Bragg grating strain sensor for monitoring ventilatory movements , 2001 .

[24]  P. Shankar,et al.  A review of fiber-optic biosensors , 2007 .