Evaluation of uncertainty predictions and dose output for model-based dose calculations for megavoltage photon beams.

In many radiotherapy clinics an independent verification of the number of monitor units (MU) used to deliver the prescribed dose to the target volume is performed prior to the treatment start. Traditionally this has been done by using methods mainly based on empirical factors which, at least to some extent, try to separate the influence from input parameters such as field size, depth, distance, etc. The growing complexity of modern treatment techniques does however make this approach increasingly difficult, both in terms of practical application and in terms of the reliability of the results. In the present work the performance of a model-based approach, describing the influence from different input parameters through actual modeling of the physical effects, has been investigated in detail. The investigated model is based on two components related to megavoltage photon beams; one describing the exiting energy fluence per delivered MU, and a second component describing the dose deposition through a pencil kernel algorithm solely based on a measured beam quality index. Together with the output calculations, the basis of a method aiming to predict the inherent calculation uncertainties in individual treatment setups has been developed. This has all emerged from the intention of creating a clinical dose/MU verification tool that requires an absolute minimum of commissioned input data. This evaluation was focused on irregular field shapes and performed through comparison with output factors measured at 5, 10, and 20 cm depth in ten multileaf collimated fields on four different linear accelerators with varying multileaf collimator designs. The measurements were performed both in air and in water and the results of the two components of the model were evaluated separately and combined. When compared with the corresponding measurements the resulting deviations in the calculated output factors were in most cases smaller than 1% and in all cases smaller than 1.7%. The distribution describing the calculation errors in the total dose output has a mean value of -0.04% and a standard deviation of 0.47%. In the dose calculations a previously developed correction of the pencil kernel was applied that managed to contract the error distribution considerably. A detailed analysis of the predicted uncertainties versus the observed deviations suggests that the predictions indeed can be used as a basis for creating action levels and tracking dose calculation errors in homogeneous media.

[1]  P. Dunscombe,et al.  On the field-size dependence of relative output from a linear accelerator. , 1992, Medical physics.

[2]  T C Zhu,et al.  A generalized solution for the calculation of in-air output factors in irregular fields. , 1998, Medical physics.

[3]  Tufve Nyholm,et al.  Photon pencil kernel parameterisation based on beam quality index. , 2006, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[4]  J. Venselaar,et al.  The determination of phantom and collimator scatter components of the output of megavoltage photon beams: measurement of the collimator scatter part with a beam-coaxial narrow cylindrical phantom. , 1991, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[5]  J Yang,et al.  Modelling of electron contamination in clinical photon beams for Monte Carlo dose calculation. , 2004, Physics in medicine and biology.

[6]  Mikael Karlsson,et al.  A widely tested model for head scatter influence on photon beam output. , 2003, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[7]  T Knöös,et al.  Application of the convolution method for calculation of output factors for therapy photon beams. , 1992, Medical physics.

[8]  Dirk Verellen,et al.  A simple theoretical verification of monitor unit calculation for intensity modulated beams using dynamic mini-multileaf collimation. , 2004, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[9]  H Hansson,et al.  Verification of a pencil beam based treatment planning system: output factors for open photon beams shaped with MLC or blocks. , 1999, Physics in medicine and biology.

[10]  T Knöös,et al.  Independent checking of the delivered dose for high-energy X-rays using a hand-held PC. , 2001, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[11]  Cristina Garibaldi,et al.  MONITOR UNIT CALCULATION FOR HIGH ENERGY PHOTON BEAMS - PRACTICAL EXAMPLES , 1997 .

[12]  A Ahnesjö,et al.  Build-up cap materials for measurement of photon head-scatter factors. , 1997, Physics in medicine and biology.

[13]  P. Storchi,et al.  Calculation of the absorbed dose distribution due to irregularly shaped photon beams using pencil beam kernels derived form basic beam data. , 1996, Physics in medicine and biology.

[14]  A. Boyer,et al.  Dose distributions of x-ray fields as shaped with multileaf collimators. , 1992, Physics in medicine and biology.

[15]  D. Georg,et al.  A formalism to calculate the output ratio in a mini-phantom for a GE multileaf collimator. , 1997, Physics in medicine and biology.

[16]  D. Georg,et al.  Pencil kernel correction and residual error estimation for quality-index-based dose calculations , 2006, Physics in medicine and biology.

[17]  A. Ahnesjö,et al.  A pencil beam model for photon dose calculation. , 1992, Medical physics.

[18]  J Olofsson,et al.  Modelling lateral beam quality variations in pencil kernel based photon dose calculations , 2006, Physics in medicine and biology.

[19]  J M Wilkinson,et al.  Head scatter modelling for irregular field shaping and beam intensity modulation. , 1997, Physics in medicine and biology.

[20]  R. van der Laarse,et al.  NCS Report 12: Determination and use of scatter correction factors of megavoltage photon beams , 1998 .

[21]  W F Hanson,et al.  A generic off-axis energy correction for linac photon beam dosimetry. , 1998, Medical physics.

[22]  A L Boyer,et al.  Modeling the extrafocal radiation and monitor chamber backscatter for photon beam dose calculation. , 2001, Medical physics.

[23]  Mikael Karlsson,et al.  On empirical methods to determine scatter factors for irregular MLC shaped beams. , 2004, Medical physics.

[24]  A Ahnesjö,et al.  Analytic modeling of photon scatter from flattening filters in photon therapy beams. , 1994, Medical physics.

[25]  T. Holmes,et al.  Analysing collimator structure effects in head-scatter calculations for IMRT class fields using scatter raytracing. , 2001, Physics in medicine and biology.