A Two-Level Iterative Reconstruction Method for Compressed Sensing MRI

This paper proposed a novel two-level iterative reconstruction method for compressed sensing magnetic resonance imaging (CS-MRI). For the model of this method, we incorporated the phase correction matrix and region of support (ROS) to guarantee more accurate reconstruction. For the algorithm of the method, we proposed an iterative strategy to reduce memory and computation time, and a two-level strategy to take into account both low and high frequency k-space data separately. Simulation results on normal brain image and angiogram of cerebral demonstrated that the median square error of this proposed method was much less than the traditional method. The error reduction ratios are 11.94% for brain image and 4.53% for angiogram of cerebral, respectively.

[1]  Cheong Boon Soh,et al.  FREQUENCY DOMAIN SKIN ARTIFACT REMOVAL METHOD FOR ULTRA-WIDEBAND BREAST CANCER DETECTION , 2009 .

[2]  Shuai Ding,et al.  Analysis of Finite Periodic Dielectric Gratings by the Finite-Difference Frequency-Domain Method with the Sub-Entire-Domain Basis Functions and Wavelets , 2009 .

[3]  Yudong Zhang,et al.  A Novel Method for Magnetic Resonance Brain Image Classification Based on Adaptive Chaotic PSO , 2010 .

[4]  Zhongmin Wang,et al.  Variable density compressed image sampling , 2009, 2009 17th European Signal Processing Conference.

[5]  Deanna Needell,et al.  CoSaMP: Iterative signal recovery from incomplete and inaccurate samples , 2008, ArXiv.

[6]  C. D. Nikolopoulos,et al.  A New Low-Profile and Cost SPA-PIFA for Mobile 2.4 GHz ISM Applications , 2010 .

[7]  Shrikanth S. Narayanan,et al.  Accelerated three‐dimensional upper airway MRI using compressed sensing , 2009, Magnetic resonance in medicine.

[8]  Shunjun Wei,et al.  SPARSE RECONSTRUCTION FOR SAR IMAGING BASED ON COMPRESSED SENSING , 2010 .

[9]  Stuart Crozier,et al.  A Genetic Algorithm/Method of Moments approach to the optimization of an RF coil for MRI applications - theoretical considerations , 2003 .

[10]  Ashwin A. Wagadarikar,et al.  Single disperser design for coded aperture snapshot spectral imaging. , 2008, Applied optics.

[11]  Norbert Schuff,et al.  Diffusion anisotropy indexes are sensitive to selecting the EPI readout-encoding bandwidth at high-field MRI. , 2008, Magnetic resonance imaging.

[12]  D. Donoho,et al.  Sparse MRI: The application of compressed sensing for rapid MR imaging , 2007, Magnetic resonance in medicine.

[13]  Yudong Zhang,et al.  WEIGHTS OPTIMIZATION OF NEURAL NETWORK VIA IMPROVED BCO APPROACH , 2008 .

[14]  Hsi-Tseng Chou,et al.  Convergence Study of Current Sampling Profiles for Antenna Design in the Presence of Electrically Large and Complex Platforms Using Fit-UTD Hybridization Approach , 2009 .

[15]  Peter Boesiger,et al.  2D sense for faster 3D MRI , 2002, Magnetic Resonance Materials in Physics, Biology and Medicine.

[16]  Oscar Vilarroya,et al.  Cerebellar neurometabolite abnormalities in pediatric attention/deficit hyperactivity disorder: A proton MR spectroscopic study , 2010, Neuroscience Letters.

[17]  David Girbau,et al.  Wavelet-Based Breast Tumor Localization Technique Using a UWB Radar , 2009 .

[18]  Clemente Cobos Sanchez,et al.  A Divergence-Free BEM Method to Model Quasi-Static Currents: Application to MRI Coil Design , 2010 .

[19]  N. M. Sheikh,et al.  MRI Induced Heating of Artificial Bone Implants , 2009 .

[20]  X.-B. Yu,et al.  PERFORMANCE OF MULTIBAND COMPLEX WAVELET BASED MULTICARRIER DS-CDMA SYSTEM WITH MULTI-ANTENNA RECEIVER OVER NAKAGAMI-m FADING CHANNEL , 2009 .

[21]  Lenan Wu,et al.  A New Classifier for Polarimetric SAR Images , 2009 .