Progress in the study of CdZnTe strip detectors

We report new performance measurements and computer simulations of a sub-millimeter pitch CdZnTe strip detector under study as a prototype imaging spectrometer for astronomical x-ray and gamma-ray observations. The prototype is 1.5 mm thick with 375 micron strip pitch in both the x and y dimensions. Previously reported work included demonstrations of half-pitch spatial resolution (approximately 190 microns) and good energy resolution and spectral uniformity. Strip detector efficiency measurements have also been presented. A model that includes the photon interaction, carrier transport and the electronics was developed that qualitatively reproduced the measurements. The new studies include measurements of the CdZnTe transport properties for this prototype in an effort to resolve quantitative discrepancies between the measurements and the simulations. Measurements of charge signals produced by laser pulses and (alpha) -rays are used to determine these transport properties. These are then used in the model to predict gamma-ray efficiencies that are compared with the data. The imaging performance of the detector is studied by scanned laser and gamma beam spot measurements. The results support the model's prediction of nearly linear sharing of the charge for interactions occurring in the region between electrodes. The potential for strip detectors with spatial resolution much finer than the strip pitch is demonstrated. A new design scheme for strip detectors is shortly discussed.

[1]  James M. Ryan,et al.  Large-area sub-millimeter resolution CdZnTe strip detector for astronomy , 1996 .

[2]  Zhong He Potential distribution within semiconductor detectors using coplanar electrodes , 1995 .

[3]  B. Hasegawa,et al.  Two-dimensional modeling of compound-semiconductor strip detectors , 1996, 1996 IEEE Nuclear Science Symposium. Conference Record.

[4]  Peter Capper,et al.  Properties of Narrow-Gap Cadmium-Based Compounds , 1995 .

[5]  H. Bradford Barber CdZnTe arrays for nuclear medicine imaging , 1996, Optics & Photonics.

[6]  Harrison H. Barrett,et al.  The effect of pixel geometry on spatial and spectral resolution in a CdZnTe imaging array , 1995, 1995 IEEE Nuclear Science Symposium and Medical Imaging Conference Record.

[7]  D. Wehe,et al.  Position sensitive single carrier CdZnTe detectors , 1996, 1996 IEEE Nuclear Science Symposium. Conference Record.

[8]  Sébastien Paquet,et al.  CHARGE TRANSPORT AND SIGNAL GENERATION IN CDTE PIXEL DETECTORS , 1996 .

[9]  James M. Ryan,et al.  Performance and simulation of CdZnTe strip detectors as sub-millimeter resolution imaging gamma radiation spectrometers , 1997 .

[10]  Mark L. McConnell,et al.  Progress in the development of large-area submillimeter-resolution CdZnTe strip detectors , 1996, Optics & Photonics.

[11]  D. M. Palmer,et al.  CZT strip detectors for imaging and spectroscopy: collimated beam and ASIC readout experiments , 1996 .

[12]  P. Luke Unipolar charge sensing with coplanar electrodes-application to semiconductor detectors , 1995 .

[13]  Michael R. Pelling,et al.  CdZnTe strip detectors for high-energy x-ray astronomy , 1996, Optics & Photonics.

[14]  Mark L. McConnell,et al.  Large-area submillimeter resolution CdZnTe strip detector for astronomy , 1995, Optics & Photonics.

[15]  P. Morse,et al.  Methods of theoretical physics , 1955 .