Automatic and visual reproducibility of perfusion and function measures for myocardial perfusion SPECT

BackgroundWe define the repeatability coefficients (RC) of key quantitative and visual perfusion and function parameters that can be derived by the QGS/QPS automated software and by expert visual observer from gated myocardial perfusion SPECT (MPS) scans.MethodsStandard QGS/QPS algorithms have been applied to derive quantitative perfusion and function parameters in 200 99mTc-tetrofosmin rest/stress MPS scans, obtained in 100 consecutive patients who underwent 2 separate gated rest/stress scans on the same camera. Variables included stress, rest, and ischemic total perfusion deficit (TPD), ejection fraction, motion, and thickening. Visual perfusion/motion scores were derived by an expert reader using randomized scan order and normalized to % myocardium.ResultsQuantitative and visual parameters were highly reproducible with smaller RC for some quantitative measures as compared to visual measures (P < .0001). RC for quantitative measures were 3.3% for stress TPD, 1.8% for rest TPD, and 3.2% for ischemic TPD and for visual scoring 4.8% for stress, 3.8% for rest, and 4.3% for ischemic (P ≤ .002). The results in each vessel territory showed that in the right coronary artery (RCA) territory the quantitative approach had improved reproducibility as compared to visual reading. Visual thickening scoring was more reproducible than motion scoring (P < .0001).ConclusionsThis study demonstrates that standard perfusion and function parameters derived from MPS by visual or quantitative analysis are highly reproducible with some advantages to the quantitative approach.

[1]  F. Wackers,et al.  Science, art, and artifacts: How important is quantification for the practicing physician interpreting myocardial perfusion studies? , 1994, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[2]  D. Berman,et al.  Reproducibility of stress redistribution thallium-201 SPECT quantitative indexes of hypoperfused myocardium secondary to coronary artery disease. , 1992, The American journal of cardiology.

[3]  D. Berman,et al.  Automated quantification of myocardial perfusion SPECT using simplified normal limits , 2004, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[4]  D. Altman,et al.  Applying the right statistics: analyses of measurement studies , 2003, Ultrasound in obstetrics & gynecology : the official journal of the International Society of Ultrasound in Obstetrics and Gynecology.

[5]  Guido Germano,et al.  Combined supine and prone quantitative myocardial perfusion SPECT: method development and clinical validation in patients with no known coronary artery disease. , 2006, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[6]  D. Berman,et al.  Anatomic and functional assessment of coronary artery disease: convergence of 2 aims in a single setting. , 2009, Circulation. Cardiovascular imaging.

[7]  Daniel S. Berman,et al.  Myocardial perfusion and function: Single photon emission computed tomography , 2006, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[8]  R. Hendel,et al.  Regadenoson induces comparable left ventricular perfusion defects as adenosine: a quantitative analysis from the ADVANCE MPI 2 trial. , 2009, JACC. Cardiovascular imaging.

[9]  T. Ruddy,et al.  Half-Time SPECT Myocardial Perfusion Imaging with Attenuation Correction , 2009, Journal of Nuclear Medicine.

[10]  Amit Ramesh,et al.  Automated Quality Control for Segmentation of Myocardial Perfusion SPECT , 2009, Journal of Nuclear Medicine.

[11]  P. Danias,et al.  Visual assessment of left ventricular perfusion and function with electrocardiography-gated SPECT has high intraobserver and interobserver reproducibility among experienced nuclear cardiologists and cardiology trainees , 2002, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[12]  M. Verani,et al.  High reproducibility of myocardial perfusion defects in patients undergoing serial exercise thallium-201 tomography. , 1995, The American journal of cardiology.

[13]  Guido Germano,et al.  Quantitative assessment of myocardial perfusion abnormality on SPECT myocardial perfusion imaging is more reproducible than expert visual analysis , 2009, Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology.

[14]  D. Berman,et al.  Automatic quantification of ejection fraction from gated myocardial perfusion SPECT. , 1995, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.