Evaluation and application of conducting polymer entrapment on quartz crystal microbalance in flow injection immunoassay.

An immunosensor employing conducting polymer entrapment (CPE) method to immobilize immuno-protein on the quartz crystal microbalance (QCM) for clinical flow-injection-analysis (FIA) purpose was exploited. By comparing the CPE approach and the conventional physical immobilization (PI) method, a frequency shift of the former was 47% higher than that of the latter when measuring at 0.5 mg/ml human serum albumin antibody concentration. This implied that CPE was a feasible approach for developing QCM-FIA process. An immunoassay of anti-pseudorabies virus antibody in mouse sera further exemplified its practical potential in diagnostic implication.

[1]  Devendra Kumar,et al.  Advances in conductive polymers , 1998 .

[2]  Christopher R. Lowe,et al.  Enzyme entrapment in electrically conducting polymers. Immobilisation of glucose oxidase in polypyrrole and its application in amperometric glucose sensors , 1986 .

[3]  E J Jarvi,et al.  Piezoelectric quartz crystal biosensors. , 1998, Talanta.

[4]  Kim R. Rogers,et al.  Biosensors for environmental applications , 1995 .

[5]  G G Guilbault,et al.  Piezoelectric crystal biosensors. , 1990, Biosensors & bioelectronics.

[6]  F. Caruso,et al.  In-situ measurement of DNA immobilization and hybridization using a 27 MHZ quartz crystal microbalance , 1998 .

[7]  S. Drost,et al.  Quartz crystal biosensor for detection of the African Swine Fever disease , 1998 .

[8]  S. Cosnier Biomolecule immobilization on electrode surfaces by entrapment or attachment to electrochemically polymerized films. A review. , 1999, Biosensors & bioelectronics.

[9]  Mettenleiter Tc Pseudorabies (Aujeszky's disease) virus: state of the art. August 1993. , 1994 .

[10]  G. Sauerbrey Verwendung von Schwingquarzen zur Wägung dünner Schichten und zur Mikrowägung , 1959 .

[11]  I Karube,et al.  A novel method of immobilizing antibodies on a quartz crystal microbalance using plasma-polymerized films for immunosensors. , 1996, Analytical chemistry.

[12]  K. Hashimoto,et al.  Quantitative analysis for solid-phase hybridization reaction and binding reaction of DNA binder to hybrids using a quartz crystal microbalance , 1996 .

[13]  Y. S. Lin,et al.  Immunolocalization of the pseudorabies virus immediate-early protein IE180 by immunoperoxidase staining. , 1997, Journal of virological methods.

[14]  G. Sauerbrey,et al.  Use of quartz vibration for weighing thin films on a microbalance , 1959 .

[15]  Philip N. Bartlett,et al.  Electrochemical immobilisation of enzymes: Part I. Theory , 1987 .

[16]  C P Price,et al.  Immunosensors: technology and opportunities in laboratory medicine. , 1996, Clinical chemistry.

[17]  John F. Alder,et al.  Piezoelectric crystals for mass and chemical measurements. A review , 1983 .

[18]  M. Umaña,et al.  Protein-modified electrodes. The glucose oxidase/polypyrrole system , 1986 .

[19]  Marek Trojanowicz,et al.  Biosensors based on oxidases immobilized in various conducting polymers , 1995 .

[20]  K. Hsiung,et al.  Comparison of different protein immobilization methods on quartz crystal microbalance surface in flow injection immunoassay. , 2001, Analytical biochemistry.