Experimental Investigation of Wood Decking Assemblies Exposed to Firebrand Showers.

Wildland-Urban Interface (WUI) fires have become a problem of great concern across multiple continents. An important mechanism of structure ignition in WUI fires and urban fires is the production of firebrands. During WUI fires, decking assemblies have been observed to be an ignition vulnerability based on post-fire damage surveys conducted by NIST and elsewhere. The authors have conducted scoping experiments and demonstrated the dangers of the dynamic process of continual, wind-driven firebrand showers landing on decking assemblies for wind speeds of 6 m/s. In this study, eight full-scale experiments were conducted with wood decking assemblies under a wind speed of 8 m/s. The basis for these new investigations was twofold: observe possible vulnerabilities of wood decking assemblies to continuous, wind-driven firebrands at higher wind speed as firebrand accumulation patterns were expected to be influenced by wind speed, and examine if wall ignition occurred due to the burning decking assembly. To this end, sections of wood decking assemblies (1.2 m by 1.2 m) were constructed and attached to a reentrant corner assembly. The deck/reentrant corner assembly was then exposed to continuous, wind-driven firebrand bombardment generated by a full-scale Continuous Feed Firebrand Generator installed in the Fire Research Wind Tunnel Facility (FRWTF) at the Building Research Institute (BRI) in Japan. The mass of firebrands required for flaming ignitions under a wind speed of 8 m/s was considerably less compared with those under a wind speed of 6 m/s. This result is postulated to be due to higher firebrand surface temperatures as the wind speed was increased. For the decking assembly to wall ignition studies, the interface between the decking assembly and the wall appeared to be a weak point; this is not addressed in the current test methods.

[1]  Samuel L. Manzello,et al.  Summary of workshop for fire structure interaction and urban and wildland-urban interface (WUI) Fires–operation Tomodachi–fire research , 2013 .

[2]  Yukio Tamura,et al.  Tachikawa number: A proposal , 2006 .

[3]  Stephen Quarles,et al.  Lessons learned from Waldo Canyon: Fire Adapted Communities Mitigation Assessment Team findings. , 2013 .

[4]  Sayaka Suzuki,et al.  Summary of the 2011 workshop on research needs for full scale testing to determine vulnerabilities of decking assemblies to ignition by firebrand showers , 2011 .

[5]  S. L. Manzello,et al.  Exposing Decking Assemblies to Continuous Wind-Driven Firebrand Showers , 2012 .

[6]  Samuel L Manzello,et al.  Special Section on Structure Ignition in Wildland-Urban Interface (WUI) Fires , 2017, Fire technology.

[7]  Samuel L. Manzello,et al.  Characterizing Firebrand Exposure from Wildland–Urban Interface (WUI) Fires: Results from the 2007 Angora Fire , 2014 .

[8]  Derek McNamara,et al.  Case Study of a Community Affected by the Waldo Fire - Event Timeline and Defensive Actions , 2015 .

[9]  Samuel L. Manzello,et al.  Investigation on the ability of glowing firebrands deposited within crevices to ignite common building materials , 2009 .

[10]  Laura E. E. Hasburgh,et al.  Laboratory Investigation of Fire Transfer from Exterior Wood Decks to Buildings in the Wildland–Urban Interface , 2017 .

[11]  Sayaka Suzuki,et al.  Generating Wind-Driven Firebrand Showers Characteristic of Burning Structures. , 2017, Proceedings of the Combustion Institute. International Symposium on Combustion.