When are actively balanced biphasic (‘Lilly’) stimulating pulses necessary in a neurological prosthesis? I Historical background; Pt resting potential;Q studies

Actively balanced (‘Lilly’) stimulating current waveforms are generally considered to give very ‘safe’ stimulation. Although this is perfectly true, the specification of the necessary waveform generators in neurological prostheses demands additional complexity, and probably additional expense and development time as well. The paper and its companion enquire whether the use of simple, passively charge-balanced stimulating pulses is equally safe, provided the stimulation parameters and circuitry are designed with appropriate care. It is concluded that, in respect of safe deliverable charge density per pulse at the electrode, release of noxious products and stimulating effectiveness, simple pulses need give no worse performance; in some circumstances they may give better.

[1]  S. B. Brummer,et al.  Activated Ir: An Electrode Suitable for Reversible Charge Injection in Saline Solution , 1983 .

[2]  J. R. Hughes,et al.  Brief, noninjurious electric waveform for stimulation of the brain. , 1955, Science.

[3]  J M Marston,et al.  Electrical stimulation with pt electrodes. IV. Factors influencing Pt dissolution in inorganic saline. , 1980, Biomaterials.

[4]  F. P. Bowden The amount of hydrogen and oxygen present on the surface of a metallic electrode , 1929 .

[5]  J M Marston,et al.  Electrical stimulation with Pt electrodes. V. The effect of protein on Pt dissolution. , 1980, Biomaterials.

[6]  B. Onaral,et al.  Linear and nonlinear properties of platinum electrode polarisation. Part 1: frequency dependence at very low frequencies , 1982, Medical and Biological Engineering and Computing.

[7]  S. Brummer,et al.  Electrical stimulation with Pt electrodes: Trace analysis for dissolved platinum and other dissolved electrochemical products. , 1977, Brain, behavior and evolution.

[8]  N. de N. Donaldson,et al.  When are actively balanced biphasic (‘Lilly’) stimulating pulses necessary in a neurological prosthesis? II pH changes; noxious products; electrode corrosion; discussion , 2006, Medical and Biological Engineering and Computing.

[9]  A. Oosterom,et al.  Electrical properties of platinum electrodes: Impedance measurements and time-domain analysis , 2006, Medical and Biological Engineering and Computing.

[10]  W. Chambers,et al.  Threshold movements produced by excitation of cerebral cortex and efferent fibers with some parametric regions of rectangular current pulses (cats and monkeys). , 1952, Journal of neurophysiology.

[11]  J. Lingane,et al.  Anodic formation and chemical analysis of oxychloride films on platinum electrodes , 1962 .

[12]  S. B. Brummer,et al.  Electrochemical Considerations for Safe Electrical Stimulation of the Nervous System with Platinum Electrodes , 1977, IEEE Transactions on Biomedical Engineering.

[13]  J. Weinman,et al.  An analysis of electrical properties of metal electrodes , 1964, Medical electronics and biological engineering.