Stability analysis of digitally controlled LCL-type grid-connected inverter considering the delay effect

Owing to LCL-filter resonance, a single loop may not be adequate to stabilise the digitally controlled LCL-type grid-connected inverter, thus the capacitor-current-feedback active damping is usually introduced. However, the computation and pulse-width modulation delays of the digitally controlled system significantly affect system stability and damping performance. Moreover, the delay varies when the duty-ratio update instant and sampling instant are changed. In this study, the Nyquist diagram is used to investigate the system stability taking into consideration the delay effect in the continuous domain. Then, the general conclusions and formulas can be drawn: if the LCL-filter resonance is above the critical frequency, the Nyquist diagram of single loop may not encircle the critical point, and therefore stabilise the system; and if it is below, a damping strategy is required. However, given the delay effect, the active damping loop may be unstable, and two unstable open-loop poles will be generated in the grid current loop under certain conditions. Then its Nyquist diagram should encircle the critical point to ensure the system is stable. Furthermore, the restriction of the cross-over frequency discussed. Experimental results based on a 5 kW prototype have been provided to verify the theoretical analysis.

[1]  H. Pinheiro,et al.  Design and Implementation of a Robust Current Controller for VSI Connected to the Grid Through an LCL Filter , 2009, IEEE Transactions on Power Electronics.

[2]  Christian Wessels,et al.  Limitations of Voltage-Oriented PI Current Control of Grid-Connected PWM Rectifiers With $LCL$ Filters , 2009, IEEE Transactions on Industrial Electronics.

[3]  Shaojun Xie,et al.  Research on low-order current harmonics rejections for grid-connected LCL-filtered inverters , 2014 .

[4]  M. Liserre,et al.  Design and control of an LCL-filter based three-phase active rectifier , 2001, Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248).

[5]  J L Agorreta,et al.  Modeling and Control of $N$ -Paralleled Grid-Connected Inverters With LCL Filter Coupled Due to Grid Impedance in PV Plants , 2011, IEEE Transactions on Power Electronics.

[6]  Bangyin Liu,et al.  Stability Analysis of Grid-Connected Inverter With LCL Filter Adopting a Digital Single-Loop Controller With Inherent Damping Characteristic , 2013, IEEE Transactions on Industrial Informatics.

[7]  Poh Chiang Loh,et al.  Improved one-cycle-control scheme for three-phase active rectifiers with input inductor-capacitor-inductor filters , 2011 .

[8]  Nilanjan Mukherjee,et al.  Analysis and improvement of performance in LCL filter-based PWM rectifier/inverter application using hybrid damping approach , 2013 .

[9]  Vinod John,et al.  Analysis and design of split-capacitor resistive-inductive passive damping for LCL filters in grid-connected inverters , 2013 .

[10]  Friedrich W. Fuchs,et al.  Models and effects of different updating and sampling concepts to the control of grid-connected PWM converters — A study based on discrete time domain analysis , 2011, Proceedings of the 2011 14th European Conference on Power Electronics and Applications.

[11]  Xinbo Ruan,et al.  Step-by-Step Controller Design for LCL-Type Grid-Connected Inverter with Capacitor–Current-Feedback Active-Damping , 2014 .

[12]  Shaojun Xie,et al.  Evaluations of current control in weak grid case for grid-connected LCL-filtered inverter , 2013 .

[13]  Xinbo Ruan,et al.  Design of injected grid current regulator and capacitor-current-feedback active-damping for LCL-type grid-connected inverter , 2012, 2012 IEEE Energy Conversion Congress and Exposition (ECCE).

[14]  R. Grino,et al.  On the stability of discrete-time active damping methods for VSI converters with a LCL input filter , 2012, IECON 2012 - 38th Annual Conference on IEEE Industrial Electronics Society.

[15]  Yun Wei Li,et al.  Generalized Closed-Loop Control Schemes with Embedded Virtual Impedances for Voltage Source Converters with LC or LCL Filters , 2012, IEEE Transactions on Power Electronics.

[16]  D. G. Holmes,et al.  Optimized Design of Stationary Frame Three Phase AC Current Regulators , 2009, IEEE Transactions on Power Electronics.

[17]  Shaojun Xie,et al.  Improved control strategy with grid-voltage feedforward for LCL-filter-based inverter connected to weak grid , 2014 .

[18]  Josep M. Guerrero,et al.  Small-Signal Modeling of Digitally Controlled Grid-Connected Inverters With $LCL$ Filters , 2013, IEEE Transactions on Industrial Electronics.

[19]  Rui Li,et al.  Influence of Delay on System Stability and Delay Optimization of Grid-Connected Inverters With LCL Filter , 2014, IEEE Transactions on Industrial Informatics.

[20]  Brendan McGrath,et al.  Regions of Active Damping Control for LCL Filters , 2014 .

[21]  Xinbo Ruan,et al.  Capacitor-Current-Feedback Active Damping With Reduced Computation Delay for Improving Robustness of LCL-Type Grid-Connected Inverter , 2014, IEEE Transactions on Power Electronics.