Radial turbo spin echo imaging

Fast MR imaging methods should provide a familiar contrast behavior at a reduced scan time. The multi‐spin echo approach (TSE) is one of the most promising techniques satisfying this condition. Although the data acquisition time is significantly reduced, image quality may still suffer from artifacts due to patient motion and flow. The radial turbo spin echo (rTSE) approach combines TSE methods and projection reconstruction (PR) techniques. In PR images, artifacts induced by patient motion or flow are known to have a different appearance with lower level of intensity. The contrast and artifact behavior of the rTSE approach has been investigated. The new technique has been applied to abdominal imaging with acquisition times shorter than 30 s and to heart imaging in combination with cardiac triggering.

[1]  Douglas C. Noll,et al.  Deblurring for non‐2D fourier transform magnetic resonance imaging , 1992, Magnetic resonance in medicine.

[2]  D G Nishimura,et al.  On the nature and reduction of the displacement artifact in flow images , 1991, Magnetic resonance in medicine.

[3]  Z. H. Cho,et al.  Line-Integral Projection Reconstruction (LPR) with Slice Encoding Techniques: Multislice Regional Imaging in NMR Tomography , 1984, IEEE Transactions on Medical Imaging.

[4]  J Hennig,et al.  RARE imaging: A fast imaging method for clinical MR , 1986, Magnetic resonance in medicine.

[5]  S. Meiboom,et al.  Modified Spin‐Echo Method for Measuring Nuclear Relaxation Times , 1958 .

[6]  C. Lai,et al.  Reconstructing NMR images from projections under inhomogeneous magnetic field and non-linear field gradients. , 1983, Physics in medicine and biology.

[7]  D. Twieg The k-trajectory formulation of the NMR imaging process with applications in analysis and synthesis of imaging methods. , 1983, Medical physics.

[8]  G H Glover,et al.  Projection Reconstruction Techniques for Reduction of Motion Effects in MRI , 1992, Magnetic resonance in medicine.

[9]  J. Pauly,et al.  A homogeneity correction method for magnetic resonance imaging with time-varying gradients. , 1991, IEEE transactions on medical imaging.

[10]  M. O’Donnell,et al.  NMR imaging in the presence of magnetic field inhomogeneities and gradient field nonlinearities. , 1985, Medical physics.

[11]  E. Purcell,et al.  Effects of Diffusion on Free Precession in Nuclear Magnetic Resonance Experiments , 1954 .

[12]  J. Duerk,et al.  Motion artifact suppression technique (MAST) for MR imaging. , 1987, Journal of computer assisted tomography.

[13]  J. Hennig Echoes—how to generate, recognize, use or avoid them in MR‐imaging sequences. Part I: Fundamental and not so fundamental properties of spin echoes , 1991 .

[14]  J M Pauly,et al.  Lung parenchyma: projection reconstruction MR imaging. , 1991, Radiology.

[15]  R C Grimm,et al.  Respiratory kinematics of the upper abdominal organs: A quantitative study , 1992, Magnetic resonance in medicine.

[16]  E M Haacke,et al.  Reducing motion artifacts in two-dimensional Fourier transform imaging. , 1986, Magnetic resonance imaging.

[17]  J G Pipe,et al.  A progressive gradient moment nulling design technique , 1991, Magnetic resonance in medicine.

[18]  J. R. Singer REVIEW ARTICLE: NMR diffusion and flow measurements and an introduction to spin phase graphing , 1978 .

[19]  Z H Cho,et al.  Reduction of flow artifacts in NMR diffusion imaging using view‐angle tilted line‐integral projection reconstruction , 1991, Magnetic resonance in medicine.