Multiscale detection of transiently evoked otoacoustic emissions

This paper presents a unified approach to multiscale detection of transient evoked otoacoustic emissions (TEOAEs). Using statistical detection theory, it is shown that the optimal detector involves a time windowing operation where the window can be estimated from ensemble correlation information. The detector performs adaptive splitting of the signal into different frequency bands using either wavelet or wavelet packet decomposition. A simplified detector is proposed in which signal energy is omitted. The results show that the simplified detector performs significantly better than existing TEOAE detectors based on wave reproducibility or the modified variance ratio, whereas the detector involving signal energy does not offer such a performance advantage.

[1]  K. Wernecke,et al.  Objective detection of transiently evoked otoacoustic emissions , 2001, Scandinavian audiology.

[2]  J Cheng,et al.  Time-frequency analysis of transient evoked otoacoustic emissions via smoothed pseudo Wigner distribution. , 1995, Scandinavian audiology.

[3]  B. Engdahl,et al.  Otoacoustic emissions in the general adult population of Nord-Trøndelag, Norway: II. Effects of noise, head injuries, and ear infections. , 2002, International journal of audiology.

[4]  Ronald R. Coifman,et al.  Entropy-based algorithms for best basis selection , 1992, IEEE Trans. Inf. Theory.

[5]  V. Marozas,et al.  Otoacoustic emissions and improved pass/fail separation using wavelet analysis and time windowing , 2006, Medical and Biological Engineering and Computing.

[6]  F Grandori,et al.  Evaluation of click evoked otoacoustic emissions in newborns: effects of time-windowing. , 1999, Audiology : official organ of the International Society of Audiology.

[7]  S. Kay Fundamentals of statistical signal processing: estimation theory , 1993 .

[8]  B. Engdahl Otoacoustic emissions in the general adult population of Nord-Trøndelag, Norway: I. Distributions by age, gender, and ear side. , 2002, International journal of audiology.

[9]  R. Quian Quiroga,et al.  Single-trial event-related potentials with wavelet denoising , 2003, Clinical Neurophysiology.

[10]  J. Guinan,et al.  Evoked otoacoustic emissions arise by two fundamentally different mechanisms: a taxonomy for mammalian OAEs. , 1999, The Journal of the Acoustical Society of America.

[11]  L Zheng,et al.  Synthesis and decomposition of transient-evoked otoacoustic emissions based on an active auditory model. , 1999, IEEE transactions on bio-medical engineering.

[12]  D. Kemp Stimulated acoustic emissions from within the human auditory system. , 1978, The Journal of the Acoustical Society of America.

[13]  K. Doyle,et al.  Comparison of newborn hearing screening by transient otoacoustic emissions and auditory brainstem response using ALGO-2. , 1998, International journal of pediatric otorhinolaryngology.

[14]  Gabriella Tognola,et al.  Time-frequency distributions of click-evoked otoacoustic emissions , 1997, Hearing Research.

[15]  Pasanen Eg,et al.  Wavelet-type analysis of transient-evoked otoacoustic emissions. , 1994 .

[16]  M.L. Whitehead,et al.  Measurement of otoacoustic emissions for hearing assessment , 1994, IEEE Engineering in Medicine and Biology Magazine.

[17]  G. Tognola,et al.  Wavelet analysis of click-evoked otoacoustic emissions , 1998, IEEE Transactions on Biomedical Engineering.

[18]  Neil J. Bershad,et al.  On estimating signal-to-noise ratio using the sample correlation coefficient (Corresp.) , 1974, IEEE Trans. Inf. Theory.

[19]  Leif Sörnmo,et al.  Detection of transient-evoked otoacoustic emissions and the design of time windows , 2002, IEEE Transactions on Biomedical Engineering.

[20]  R. Bickford,et al.  Brain stem auditory evoked potentials: the use of noise estimate. , 1980, Electroencephalography and clinical neurophysiology.

[21]  J. L. Flanagan,et al.  Models for approximating basilar membrane displacement , 1960 .

[22]  Peter John Bray A study of the properties of click evoked otoacoustic emissions and development of a clinical otoacoustic hearing test instrument , 1989 .

[23]  D. McFadden,et al.  Otoacoustic emissions and quinine sulfate. , 1994, The Journal of the Acoustical Society of America.

[24]  M. J. McCoy,et al.  Time‐Windowing of Click‐Evoked Otoacoustic Emissions to Increase Signal‐to‐Noise Ratio , 1995, Ear and hearing.

[25]  L. Sornmo,et al.  Signal-to-noise ratio enhancement of cardiac late potentials using ensemble correlation , 1995, IEEE Transactions on Biomedical Engineering.

[26]  Paul Avan,et al.  Wavelet analysis of real ear and synthesized click evoked otoacoustic emissions , 1994, Hearing Research.

[27]  L. Sornmo,et al.  Otoacoustic emissions and improved pass/fail separation using wavelet based denoising , 1998, Proceedings of the 20th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Vol.20 Biomedical Engineering Towards the Year 2000 and Beyond (Cat. No.98CH36286).

[28]  A. Sayeed,et al.  Time-scale detection of microemboli in flowing blood with Doppler ultrasound , 1999, IEEE Transactions on Biomedical Engineering.

[29]  B. Vohr,et al.  Identification of Neonatal Hearing Impairment: A Multicenter Investigation , 2000, Ear and hearing.

[30]  W Jesteadt,et al.  Analysis of transient-evoked otoacoustic emissions in normal-hearing and hearing-impaired ears. , 1993, The Journal of the Acoustical Society of America.

[31]  T. Kuo,et al.  Modification of the wavelet method used in transiently evoked otoacoustic emission pass/fail criterion to increase its accuracy , 2006, Medical and Biological Engineering and Computing.

[32]  C Elberling,et al.  Quality estimation of averaged auditory brainstem responses. , 1984, Scandinavian audiology.

[33]  James W. Hall,et al.  Handbook of Otoacoustic Emissions , 1999 .