Corrective force analysis for scoliosis from implant rod deformation.

BACKGROUND Scoliosis is a serious disease in which a human spine is abnormally deformed in three dimensions with vertebral rotation. Surgical treatment is attained when the scoliotic spine is corrected into its normal shape by implant rods and screws fixed into the vertebrae. The three-dimensional corrective forces acting at the screws deformed the implant rod during the surgical treatment of scoliosis. The objective of this study was to propose a method to analyze the three-dimensional forces acting at the rod using the changes of implant rod geometry before and after the surgical treatment. METHODS An inverse method based on Finite Element Analysis is proposed. The geometries of implant rod before and after the surgical treatment were measured three dimensionally. The implant rod before the surgical treatment was reconstructed using an elasto-plastic finite element model. The three-dimensional forces were applied iteratively to the rod through the screws such that the rod is deformed the same after the surgical treatment of scoliosis. FINDINGS The maximum force acting at the screw of each patient ranged from 198N to 439N. The magnitude of forces was clinically acceptable. The maximum forces occurred at the lowest fixation level of vertebra of each patient. INTERPRETATION The three-dimensional forces distribution that deformed the rod can be evaluated using the changes of implant geometry. Although the current clinical cases are still few, this study demonstrated the feasibility of measuring the forces that deformed the implant rod after the surgical treatment of scoliosis.

[1]  E. Benzel,et al.  Biomechanics of spinal deformity. , 2003, Neurosurgical focus.

[2]  U Liljenqvist,et al.  Pullout strength of pedicle screws versus pedicle and laminar hooks in the thoracic spine. , 2001, Acta orthopaedica Belgica.

[3]  Rüdiger Krauspe,et al.  Pullout strength of anterior spinal instrumentation: a product comparison of seven screws in calf vertebral bodies , 2007, European Spine Journal.

[4]  Hubert Labelle,et al.  Biomechanical modeling and analysis of a direct incremental segmental translation system for the instrumentation of scoliotic deformities. , 2011, Clinical biomechanics.

[5]  Wafa Skalli,et al.  Intraoperative Three-Dimensional Correction During Rod Rotation Technique , 2009, Spine.

[6]  Carl-Eric Aubin,et al.  Simulation of an anterior spine instrumentation in adolescent idiopathic scoliosis using a flexible multi-body model , 2007, Medical & Biological Engineering & Computing.

[7]  J. Paige Little,et al.  Development of a Computer Simulation Tool for Application in Adolescent Spinal Deformity Surgery , 2010, ISMBS.

[8]  K. Zielke Ventrale Derotationsspondylodese. Behandlungsergebnisse bei Idiopathischen Lumbalskoliosen , 1982 .

[9]  Meic H. Schmidt,et al.  ROD DEROTATION TECHNIQUES FOR THORACOLUMBAR SPINAL DEFORMITY , 2008, Neurosurgery.

[10]  D. L. Hill,et al.  Instrumented rod rotator system for spinal surgery , 2006, Medical and Biological Engineering and Computing.

[11]  K. Zielke [Ventral derotation spondylodesis. Results of treatment of cases of idiopathic lumbar scoliosis (author's (author's transl)]. , 1982, Zeitschrift fur Orthopadie und ihre Grenzgebiete.

[12]  J Dubousset,et al.  NEW UNIVERSAL INSTRUMENTATION IN SPINAL SURGERY , 1988, Clinical orthopaedics and related research.

[13]  K Kaneda,et al.  A mathematical expression of three-dimensional configuration of the scoliotic spine. , 1996, Journal of biomechanical engineering.

[14]  M. O’Brien,et al.  Spinal Deformities: The Comprehensive Text , 2003 .

[15]  J. Dubousset Early failure of short-segment pedicle instrumentation for thoracolumbar fractures. A preliminary report. , 1995, The Journal of bone and joint surgery. American volume.

[16]  Manabu Ito,et al.  Simultaneous double-rod rotation technique in posterior instrumentation surgery for correction of adolescent idiopathic scoliosis. , 2010, Journal of neurosurgery. Spine.

[17]  L. Pugh,et al.  Cotrel-Dubousset instrumentation. Results in 52 patients. , 1993, Spine.

[18]  Francesco Lolli,et al.  Complications of Thoracic Pedicle Screws in Scoliosis Treatment , 2007, Spine.