Experimental Machine Liver Perfusion ex vivo: First Russian Case-Report

Background/Objectives: The article describes preclinical trials of a new apparatus for normothermic machine perfusion of the donor liver that was designed and developed in the Central Research Institute of Robotics and Technical Cybernetics (Saint-Petersburg, Russia). Methods: An experimental study of a new apparatus for isolated perfusion of donor liver was performed on the isolated pig liver. Microcirculation parameters were controlled using computerized dopplerography ultrasound for blood flow studies MM-E-K. Findings: The device consists of the following components - two pumps for pumping fluids in two hydraulic circuits; container, wherein the sealed package is a liver transplant; pump control system; touch screen for setting input and output; uninterruptible power supply to provide mobile functions. Porcine liver was isolated, explanted and after 30 minutes of warm ischemia time it was placed into the apparatus from the pig after induced cardiac death. Liver was perfused with a perfusate of an original composition maintaining its viability. The developed apparatus maintained separate peristaltic blood flow in portal vein at 1.5 l/min and in common hepatic artery at 0.3 l/min, which corresponds to the physiological parameters. Perfusion using the developed apparatus for machine perfusion allowed restoring and preserving the functional state of the liver after 30 minutes of warm ischemia time, as evidenced by spontaneous recovery of the bile outflow, color and texture of the liver graft. Biochemical data values stabilize at physiological levels within 40 minutes after the start of perfusion. Applications/Improvements: The perfusion device is designed to restore and maintain the viability of the donor organ (liver) using extracorporeal flow normothermic perfusion of donor organs.

[1]  M. Kinkhabwala,et al.  Hypothermic Machine Preservation in Human Liver Transplantation: The First Clinical Series , 2010, American journal of transplantation : official journal of the American Society of Transplantation and the American Society of Transplant Surgeons.

[2]  B. Leskosek,et al.  One Hour Hypothermic Oxygenated Perfusion (HOPE) Protects Nonviable Liver Allografts Donated After Cardiac Death , 2009, Annals of surgery.

[3]  M. Vairetti,et al.  Correlation between the liver temperature employed during machine perfusion and reperfusion damage: Role of Ca2+ , 2008, Liver transplantation : official publication of the American Association for the Study of Liver Diseases and the International Liver Transplantation Society.

[4]  P. Clavien,et al.  Novel Short-term Hypothermic Oxygenated Perfusion (HOPE) System Prevents Injury in Rat Liver Graft From Non-Heart Beating Donor , 2006, Annals of surgery.

[5]  R. Rozental Organ donors: deceased or alive? Quo vadis? , 2006, Annals of Transplantation.

[6]  M. Manyalich,et al.  The Effect of Normothermic Recirculation is Mediated by Ischemic Preconditioning in NHBD Liver Transplantation , 2005, American journal of transplantation : official journal of the American Society of Transplantation and the American Society of Transplant Surgeons.

[7]  T. Roskams,et al.  Livers from non-heart-beating donors tolerate short periods of warm ischemia. , 2005, Transplantation.

[8]  Hongzhi Xu,et al.  Ex-vivo study of flow dynamics and endothelial cell structure during extended hypothermic machine perfusion preservation of livers. , 2004, Cryobiology.

[9]  M. Clemens,et al.  Functional recovery of preserved livers following warm ischemia: improvement by machine perfusion preservation , 2002, Transplantation.

[10]  T. Iijima,et al.  Hepatic allograft procurement from non-heart-beating donors: limits of warm ischemia in porcine liver transplantation. , 1997, Transplantation.

[11]  T. V. van Gulik,et al.  Seventy-two-hour preservation of the canine liver by machine perfusion. , 1990, Transplantation.

[12]  T. Starzl,et al.  Experience in hepatic transplantation , 1969 .

[13]  T. Starzl,et al.  SUCCESSFUL ORTHOTOPIC TRANSPLANTATION OF LIVER HOMOGRAFTS AFTER EIGHT TO TWENTY-FIVE HOURS PRESERVATION. , 1967, Surgical forum.