Protection strategy for fault detection in inverter-dominated low voltage AC microgrid

Abstract This paper presents a protection strategy based on active power flow direction, current magnitude and voltage sags to determine the existence of low impedance faults in inverter-dominated low voltage AC microgrids. Different fault situations are considered, concerning each element of the microgrid (line section, load, node and energy sources). Simulation is done in MATLAB/Simulink software. Microgrid was modelled based on CIGRE benchmark for network integration of renewable and distributed energy resources, considering the low voltage european distribution network characteristics. Inverter-based distributed generation units were modelled considering a control scheme composed by natural reference frame control and RMS current limiter. The results obtained from simulations indicate that the proposed strategy is able to protect the microgrid in any topology configuration or mode of operation, for all type of low impedance faults.

[1]  M.A. Redfern,et al.  A voltage based protection for micro-grids containing power electronic converters , 2006, 2006 IEEE Power Engineering Society General Meeting.

[2]  S. Chaitusaney,et al.  Impacts of inverter-based distributed generation control modes on short-circuit currents in distribution systems , 2012, 2012 7th IEEE Conference on Industrial Electronics and Applications (ICIEA).

[3]  Timothy C. Green,et al.  Fault models of inverter-interfaced distributed generators: Experimental verification and application to fault analysis , 2011, 2011 IEEE Power and Energy Society General Meeting.

[4]  Wentao Huang,et al.  Protection scheme for active distribution networks using positive-sequence components , 2015, 2015 IEEE Power & Energy Society General Meeting.

[5]  Osama A. Mohammed,et al.  Multi-Agent-Based Technique for Fault Location, Isolation, and Service Restoration , 2017 .

[6]  J.C. Gomez,et al.  Distributed generation: Exploitation of islanding operation advantages , 2008, 2008 IEEE/PES Transmission and Distribution Conference and Exposition: Latin America.

[7]  Timothy C. Green,et al.  Fault response of grid-connected inverter dominated networks , 2010, IEEE PES General Meeting.

[8]  M. Parniani,et al.  A Comprehensive Digital Protection Scheme for Low-Voltage Microgrids with Inverter-Based and Conventional Distributed Generations , 2017, IEEE Transactions on Power Delivery.

[9]  Osama A. Mohammed,et al.  Protection of Autonomous Microgrids Using Agent-Based Distributed Communication , 2017, IEEE Transactions on Power Delivery.

[10]  S. P. Chowdhury,et al.  Protection of domestic solar photovoltaic based microgrid , 2012 .

[11]  Geza Joos,et al.  A Combined Wavelet and Data-Mining Based Intelligent Protection Scheme for Microgrid , 2016, IEEE Transactions on Smart Grid.

[12]  Geng Niu,et al.  Fault transient analysis in microgrid using discrete wavelet transform , 2015, 2015 5th International Conference on Electric Utility Deregulation and Restructuring and Power Technologies (DRPT).

[13]  Fei Wang,et al.  Good Consumer or Bad Consumer: Economic Information Revealed From Demand Profiles , 2018, IEEE Transactions on Smart Grid.

[14]  Mahesh S. Illindala,et al.  Comprehensive Protection Strategy for an Islanded Microgrid Using Intelligent Relays , 2017 .

[15]  Tarlochan S. Sidhu,et al.  A Protection Strategy and Microprocessor-Based Relay for Low-Voltage Microgrids , 2011, IEEE Transactions on Power Delivery.

[16]  Christoph Haederli,et al.  Network integration of distributed power generation , 2002 .

[17]  Timothy C. Green,et al.  Modelling and Analysis of Fault Behaviour of Inverter Microgrids to Aid Future Fault Detection , 2007, 2007 IEEE International Conference on System of Systems Engineering.

[18]  R. Iravani,et al.  Microgrids management , 2008, IEEE Power and Energy Magazine.

[19]  Hemanshu R. Pota,et al.  Overview of AC Microgrid Controls with Inverter-Interfaced Generations , 2017 .