The effect of removal of cerebrospinal fluid on cephalad spread of spinal analgesia with 0.5% plain bupivacaine

Increased intraabdominal pressure is well known to cause higher cephalad spread of spinal analgesia. The reason for this is believed to be a decrease in the cerebrospinal fluid (CSF) volume. If this mechanism is correct, then the cephalad spread of local anesthetic solutions should also be facilitated when the CSF volume is intentionally reduced without increasing the intraabdominal pressure. Sixty‐six patients without evidence of increased intraabdominal pressure and undergoing urological procedures were randomly allocated to three groups. All received 10 mg 0.5% bupivacaine for spinal anesthesia. In Group I, the anesthetic was injected after free drops of CSF. In Groups II and III, three and five ml were removed, respectively, before injecting bupivacaine. Mean cephalad spread of analgesia 20 min after injection in the three groups was T10.2 2.0, T9.4 1.8 and T7.0 2.1, respectively. When CSF was reduced by 5 ml, the level of spread not only showed a statistically significant difference from that of the control group, but also from that of Group II (P< 0.05). Our results show that higher cephalad spread of spinal anesthetic is possible by reducing the CSF volume without evidence of increased intraabdominal pressure.

[1]  R. Fishman Cerebrospinal Fluid in Diseases of the Nervous System , 1992 .

[2]  Michael J. Cousins,et al.  Neural Blockade in Clinical Anesthesia and Management of Pain , 1988 .

[3]  P. Rosenberg,et al.  Effect of Aspiration of Cerebro‐Spinal Fluid on Spinal Anaesthesia with Isobaric 0.5% Bupivacaine , 1985, Acta anaesthesiologica Scandinavica.

[4]  N. M. Greene Distribution of Local Anesthetic Solutions within the Subarachnoid Space , 1985, Anesthesia and analgesia.

[5]  P. Rosenberg,et al.  Influence of age on spinal anaesthesia with isobaric 0.5% bupivacaine. , 1984, British journal of anaesthesia.

[6]  H. Edström,et al.  Spinal Anaesthesia with Hyperbaric 0.5 % Bupivacaine: Effects of Volume , 1982, Acta anaesthesiologica Scandinavica.

[7]  P. Vaagenes,et al.  Spinal analgesia with hyperbaric bupivacaine: effects of volume of solution. , 1982, British journal of anaesthesia.

[8]  A. Cameron,et al.  Spinal analgesia using bupivacaine 0·5% plain Variation in the extent of the block with patient age , 1981, Anaesthesia.

[9]  G. di Chiro,et al.  Spinal descent of cerebrospinal fluid in man , 1976, Neurology.

[10]  D. Barclay,et al.  The influence of inferior vena cava compression on the level of spinal anesthesia. , 1968, American journal of obstetrics and gynecology.

[11]  R D ADAMS,et al.  STRIATO-NIGRAL DEGENERATION. , 1964, Journal of neuropathology and experimental neurology.

[12]  W. C. Worthington,et al.  CILIARY MOVEMENT IN THE RAT CEREBRAL VENTRICLES: CLEARING ACTION AND DIRECTIONS OF CURRENTS. , 1964, Journal of neuropathology and experimental neurology.

[13]  D. Scott,et al.  Studies of the Inferior Vena Cava in Late Pregnancy , 1964, British medical journal.

[14]  E. Freer Treatment of Caries of the Spine , 1884 .