Heat transfer in metal foams and designed porous media

Abstract We present the characterization of heat transfer in commercial metal foam filled tubular reactors in comparison to a designed laser sintered device. The investigations are performed at empty tube Reynolds numbers ranging from 600 to 7600. Volumetric heat transfer performances up to 4.5 MW/(m 3  K) were estimated by means of a simple calorimetric measurement setup, which is 3 orders of magnitude higher compared to conventional batch reactors. The heat transfer was found to increase with the ligament diameter ascribed to the enhanced turbulent kinetic energy induced. The fixed wall connection of the fully sintered device, realized by the applied manufacturing method, leads to 30% improvement of the heat transfer compared to no connection. Selective laser sintering was found to be an efficient tool for the design of continuous heat exchanger reactors covering a wide range of applications by simply adapting the geometry.

[1]  Indrani Ghosh How Good Is Open-Cell Metal Foam as Heat Transfer Surface? , 2009 .

[2]  Arturo A. Fuentes,et al.  Thermal performance of aluminium‐foam CPU heat exchangers , 2006 .

[3]  R. Mahajan,et al.  Metal Foam and Finned Metal Foam Heat Sinks for Electronics Cooling in Buoyancy-Induced Convection , 2006 .

[4]  W. Roberts,et al.  A study on pressure drop and heat transfer in open cell metal foams for jet engine applications , 2007 .

[5]  D. Poulikakos,et al.  The Effects of Compression and Pore Size Variations on the Liquid Flow Characteristics in Metal Foams , 2002 .

[6]  Patrice Tochon,et al.  Micromixing enhancement by turbulence: Application to multifunctional heat exchangers , 2006 .

[7]  F. Luck,et al.  The effective thermal properties of solid foam beds: Experimental and estimated temperature profiles , 2010 .

[8]  G. Groppi,et al.  Mass-Transfer Characterization of Metallic Foams as Supports for Structured Catalysts , 2005 .

[9]  W. Hsieh,et al.  Height Effect on Heat-Transfer Characteristics of Aluminum-Foam Heat Sinks , 2006 .

[10]  Michel Cabassud,et al.  Heat exchanger/reactors (HEX reactors) : Concepts, technologies: State-of-the-art , 2008 .

[11]  K. Hooman,et al.  Metal Foam Heat Exchangers for Heat Transfer Augmentation from a Cylinder in Cross-Flow , 2011 .

[12]  H. Hangan,et al.  Thermal characterization of porous graphitic foam - Convection in impinging flow , 2009 .

[13]  Howard P. Hodson,et al.  The temperature dependence of effective thermal conductivity of open-celled steel alloy foams , 2004 .

[14]  N. Celi̇k,et al.  Experimental investigation of forced and mixed convection heat transfer in a foam-filled horizontal rectangular channel , 2009 .

[15]  Anthony M. Waas,et al.  Convective heat transfer in open cell metal foams , 2007 .

[16]  Enrico Tronconi,et al.  Heat Transfer Characterization of Metallic Foams , 2005 .

[17]  M. Kaviany Principles of heat transfer in porous media , 1991 .

[18]  R. Mahajan,et al.  Thermophysical properties of high porosity metal foams , 2002 .

[19]  S. Kuhn,et al.  Scalar transport in a milli-scale metal foam reactor , 2010 .

[20]  Simon Kuhn,et al.  Large eddy simulation of flow through a streamwise-periodic structure , 2011 .

[21]  Roop L. Mahajan,et al.  Non-Darcy natural convection in high porosity metal foams , 2002 .

[22]  Adrian Zenklusen,et al.  Axial dispersion in metal foams and streamwise-periodic porous media , 2011 .

[23]  Abdulmajeed A. Mohamad,et al.  Experimental Investigation of the Potential of Metallic Porous Inserts in Enhancing Forced Convective Heat Transfer , 2004 .

[24]  Yiannis Ventikos,et al.  Simulations of flow through open cell metal foams using an idealized periodic cell structure , 2003 .

[25]  D. Poulikakos,et al.  On the effective thermal conductivity of a three-dimensionally structured fluid-saturated metal foam , 2001 .

[26]  Dimos Poulikakos,et al.  Metal foams as compact high performance heat exchangers , 2003 .