An online emission spectral tomography system with digital signal processor.

Emission spectral tomography (EST) has been adopted to test the three-dimensional distribution parameters of fluid fields, such as burning gas, flame and plasma etc. In most cases, emission spectral data received by the video cameras are enormous so that the emission spectral tomography calculation is often time-consuming. Hence, accelerating calculation becomes the chief factor that one must consider for the practical application of EST. To solve the problem, a hardware implementation method was proposed in this paper, which adopted a digital signal processor (DSP) DM642 in an emission spectral tomography test system. The EST algorithm was fulfilled in the DSP, then calculation results were transmitted to the main computer via the user datagram protocol. Compared with purely VC++ software implementations, this new approach can decrease the calculation time significantly.

[1]  M. Nakajima,et al.  Light emission computed tomography system for plasma diagnostics. , 1987, Applied optics.

[2]  Yiqing Gao,et al.  Three-dimensional plasma field reconstruction with multiobjective optimization emission spectral tomography. , 2004, Journal of the Optical Society of America. A, Optics, image science, and vision.

[3]  Gennady N. Vishnyakov,et al.  Emission spectral tomography of multijet plasma flow , 1994, Defense, Security, and Sensing.

[4]  Fan Yang,et al.  Real-time implementation of face tracking on DSP TMS320C6x embedded system , 2003, International Congress on High-Speed Imaging and Photonics.

[5]  Jue Wang,et al.  The application of volumetric region growing in segmentation for volume data from industrial computed tomography , 2005, ICMIT: Mechatronics and Information Technology.

[6]  Yiqing Gao,et al.  Radon transform iteration based on beam-deflection optical tomography , 2000, Optics and Optoelectronic Inspection and Control.

[7]  Jonathan S. Maltz,et al.  Multiresolution constrained least-squares algorithm for direct estimation of time activity curves from dynamic ECT projection data , 2000, Medical Imaging: Image Processing.

[8]  Aihan Yin,et al.  Denoising multicriterion iterative reconstruction in emission spectral tomography. , 2007, Applied optics.

[9]  Y S Cheng Two-dimensional grating interferometric imaging by computed tomography. , 1987, Optics letters.

[10]  J A Liburdy,et al.  Three-dimensional image reconstruction using interferometric data from a limited field of view with noise. , 1991, Applied optics.