Microfluidic system for screening disease based on physical properties of blood

Introduction: A key feature of the 'One Health' concept pertains to the design of novel point of care systems for largescale screening of health of the population residing in resource-limited areas of low- and middle-income countries with a view to obtaining data at a community level as a rationale to achieve better public health outcomes. The physical properties of blood are different for different samples. Our study involved the development of an innovative system architecture based upon the physical properties of blood using automated classifiers to enable large-scale screening of the health of the population living in resource-limited settings. Methods: The proposed system consisted of a simple, robust and low-cost sensor with capabilities to sense and measure even the minute changes in the physical properties of blood samples. In this system, the viscosity of blood was derived from a power-law model coupled with the Rabinowitsch-Mooney correction for non-Newtonian shear rates developed in a steady laminar Poiseuille flow. Surface tension was measured by solving the Young-Laplace equation for pendant drop shape hanging on a vertical needle. An anticipated outcome of this study would be the development of a novel automated classifier based upon the rheological attributes of blood. This automated classifier would have potential application in evaluating the health status of a population at regional and global levels. Results: The proposed system was used to measure the physical properties of various samples like normal, tuberculous and anemic blood samples. The results showed that the physical properties of these samples were different as compared to normal blood samples. The major advantage of this system was low-cost, as well as its simplicity and portability. Conclusion: In this work, we proposed making a case for the validation of a low-cost version of a microfluidic system capable of scanning large populations for a variety of diseases as per the WHO mandate of "One Health".

[1]  Talukder Z. Jubery,et al.  Blood rheology in shear and uniaxial elongation , 2016, Rheologica Acta.

[2]  O. Filatova,et al.  Effects of age and sex on rheological properties of blood , 2015, Human Physiology.

[3]  Serge Dmitrieff,et al.  Balance of microtubule stiffness and cortical tension determines the size of blood cells with marginal band across species , 2016, Proceedings of the National Academy of Sciences.

[4]  A. Jouyban,et al.  Surface tension in human pathophysiology and its application as a medical diagnostic tool , 2015, BioImpacts : BI.

[5]  P Tikuisis,et al.  Calibration of a bubble evolution model to observed bubble incidence in divers. , 1995, Undersea & hyperbaric medicine : journal of the Undersea and Hyperbaric Medical Society, Inc.

[6]  M. Gatzoulis,et al.  Blood viscosity and its relationship to iron deficiency, symptoms, and exercise capacity in adults with cyanotic congenital heart disease. , 2006, Journal of the American College of Cardiology.

[7]  Yap Boon Kar,et al.  Potential Point-of-Care Microfluidic Devices to Diagnose Iron Deficiency Anemia , 2018, Sensors.

[8]  Priya Ranjan,et al.  Modelling of Blood Flow in Stenosed Arteries , 2017 .

[9]  A. Devgan,et al.  Iron deficiency anemia in children with cyanotic congenital heart disease and effect on cyanotic spells. , 2017, Medical journal, Armed Forces India.

[10]  Nick Laan,et al.  Volume Determination of Fresh and Dried Bloodstains by Means of Optical Coherence Tomography , 2014, Journal of forensic sciences.

[11]  K. Rohini,et al.  Assessment of Hematological Parameters in Pulmonary Tuberculosis Patients , 2015, Indian Journal of Clinical Biochemistry.

[12]  M. Kelm,et al.  Red Blood Cell Function and Dysfunction: Redox Regulation, Nitric Oxide Metabolism, Anemia , 2017, Antioxidants & redox signaling.

[13]  Catherine Picart,et al.  Human blood shear yield stress and its hematocrit dependence , 1998 .

[14]  Ayush Goyal,et al.  Automatic disease screening method using image processing for dried blood microfluidic drop stain pattern recognition , 2016, Journal of medical engineering & technology.

[15]  H. -. Kim,et al.  Disposable microfluidic blood cuvette for measuring hemoglobin concentration , 2014 .

[16]  Ayush Goyal,et al.  Imaging-Based Method for Precursors of Impending Disease from Blood Traces , 2017 .

[17]  O. Baskurt,et al.  Blood Rheology and Hemodynamics , 2003, Seminars in thrombosis and hemostasis.

[18]  Ayush Goyal,et al.  Automatic Pattern Recognition for Detection of Disease from Blood Drop Stain Obtained with Microfluidic Device , 2015, SIRS.

[19]  D. Brutin,et al.  Pattern formation in drying drops of blood , 2010, Journal of Fluid Mechanics.

[20]  D. Castner,et al.  Biomedical surface science: Foundations to frontiers , 2002 .

[21]  T. A. Yakhno,et al.  Drying Drop Technology as a Possible Tool for Detection Leukemia and Tuberculosis in Cattle , 2015 .

[22]  Kit Shan Lee,et al.  Iron deficiency. , 1992, The New Zealand medical journal.

[23]  O. Baskurt,et al.  Blood rheology and aging , 2013, Journal of geriatric cardiology : JGC.

[24]  R. Deegan,et al.  Pattern formation in drying drops , 2000, Physical review. E, Statistical physics, plasmas, fluids, and related interdisciplinary topics.

[25]  E. Kvašňák,et al.  Temperature dependence of blood surface tension. , 2007, Physiological research.

[26]  Young I. Cho,et al.  A new method for blood viscosity measurement , 2000 .

[27]  J. Houston,et al.  The blood sedimentation rate and fractional plasma viscosity in pulmonary tuberculosis. , 1955, The British journal of tuberculosis and diseases of the chest.

[28]  A. Krishnan,et al.  Liquid-vapor interfacial tension of blood plasma, serum and purified protein constituents thereof. , 2005, Biomaterials.

[29]  Dohyung Lim,et al.  Determination of rheological properties of whole blood with a scanning capillary-tube rheometer using constitutive models , 2009 .

[30]  Daniel Attinger,et al.  Fluid dynamics topics in bloodstain pattern analysis: comparative review and research opportunities. , 2013, Forensic science international.

[31]  E. Hrncír,et al.  Surface tension of blood. , 1997, Physiological research.