Study of Non-Intrusive Gas Pipeline Leak Detection with Acoustic Sensor

Abstract A new non-intrusive gas pipeline leak detection method is proposed. Piezoelectric acoustic sensor is pasted on the outer wall of the metal gas pipe to measure the low-frequency acoustic leak signals which propagate through the gas in the pipeline. The feasibility of the non-intrusive gas pipeline leak detection is validated. Features of transient and continuous leak signals sampled with non-intrusive method at different leakage rates are analyzed. It illustrates that not only transient but also continuous leak signal can be detected with the proposed detection method. The method can be applied into both permanent leak monitoring and temporary safety assessments.

[1]  R. J. Pinnington,et al.  Axisymmetric vibrational power measurement in empty and fluid filled pipes , 1996 .

[2]  Yan Zhou,et al.  Study on the distributed optical fiber sensing technology for pipeline leakage protection , 2006, Advanced Laser Technologies.

[3]  J. Franzke,et al.  Gas leak detection by diode laser absorption spectrometry , 1999 .

[4]  Ai Chang-sheng Pipeline acoustic propagation features and recognition of typical damage sounds , 2006 .

[5]  Michael Savic,et al.  Leak monitoring system for gas pipelines , 1993, 1993 IEEE International Conference on Acoustics, Speech, and Signal Processing.

[6]  Wei Huang,et al.  Natural gas pipeline leak detector based on NIR diode laser absorption spectroscopy. , 2006, Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy.

[7]  Paul Parker,et al.  Detection of hydrocarbon fuel spills using a distributed fibre optic sensor , 2003 .

[8]  Sun Jian Features extraction of pipeline leak signal with operational conditions adaptability , 2008 .

[9]  Mark P. Wernet,et al.  Application of DPIV to study both steady state and transient turbomachinery flows , 2000 .

[10]  Hao Ye,et al.  Analysis of the smallest detectable leakage flow rate of negative pressure wave-based leak detection systems for liquid pipelines , 2008, Comput. Chem. Eng..

[11]  Ping Li,et al.  Approximate entropy-based leak detection using artificial neural network in water distribution pipelines , 2010, ICARCV.

[12]  Serguei V. Miridonov,et al.  Fiber Bragg grating sensor for petroleum hydrocarbon leak detection , 1999 .

[13]  Mahmoud Meribout,et al.  A New Concept for an Effective Leak Detection in Multiphase Fluid Pipelines , 2010, 2010 First International Conference on Sensor Device Technologies and Applications.

[14]  David John Hill,et al.  Distributed fibre optic sensors for pipeline protection , 2009 .

[15]  Mohamed F. Younis,et al.  A sensor network for non-intrusive and efficient leak detection in long pipelines , 2011, 2011 IFIP Wireless Days (WD).

[16]  Serguei V. Miridonov,et al.  Coherent optical frequency domain reflectometry for interrogation of bend-based fiber optic hydrocarbon sensors , 2004 .