Feasible Evaluation of Shunt Active Filter for Harmonics Mitigation in Induction Heating System

This paper propounds the incorporation of a three-level inverter based Shunt Active Filter (SAF) in the Induction Heating (IH) system to eradicate the problems due to Electromagnetic Interference (EMI) & Radio Frequency Interference (RFI). The IH system generates a considerable amount of high-frequency harmonics because of myriad causes, the predominant one being the high-frequency switching in the resonant inverter. The former has an immanent propensity to flow towards the supply side and results in the enfeeblement of power quality. Moreover, in the present work, attention has been paid off to develop a proper control strategy of a three level inverter based SAF for EMI and RFI suppression. A new modeling approach of three-level inverter based SAF is proposed and the efficacy and viability of the proposed controllers for SAF in the IH system are validated via simulations in PSIM. A comparative analysis of THD in the input current waveform has been done to advocate the desideratum of SAF as an imperative part of the IH system. Results obtained by simulations show that the proposed approach is more effective than the reviewed approaches on compensating the harmonic currents and thus, the filtering action of SAF is able to achieve the THD of input current within the limit specified by the IEEE-519 standard. Doi: 10.28991/HIJ-2021-02-03-08 Full Text: PDF

[1]  Saad Mekhilef,et al.  Active power filter (APF) for mitigation of power quality issues in grid integration of wind and photovoltaic energy conversion system , 2017 .

[2]  Kanungo Barada Mohanty,et al.  Improvement of Power Quality Using a Robust Hybrid Series Active Power Filter , 2017, IEEE Transactions on Power Electronics.

[3]  Kamal Al-Haddad,et al.  Experimental Investigation on a Hybrid Series Active Power Compensator to Improve Power Quality of Typical Households , 2016, IEEE Transactions on Industrial Electronics.

[4]  Tae Hyun Sung,et al.  One-Cycle Control of Three-Phase Five-Level Diode-Clamped STATCOM , 2021 .

[5]  F. Profumo,et al.  Current control strategy for power conditioners using sinusoidal signal integrators in synchronous reference frame , 2005, IEEE Transactions on Power Electronics.

[6]  Teuku Meurah Indra Mahlia,et al.  Grid-connected renewable energy sources: Review of the recent integration requirements and control methods , 2020 .

[7]  Anand Kumar,et al.  Design and analysis of RFI and EMI suppressor for high frequency induction heater using filters — A comparative study , 2018, 2018 4th International Conference on Recent Advances in Information Technology (RAIT).

[8]  Tzung-Lin Lee,et al.  An Active Filter With Resonant Current Control to Suppress Harmonic Resonance in a Distribution Power System , 2016, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[9]  Orhan Kaplan,et al.  Design and Implementation of Sensorless DC Voltage Regulation for Shunt Active Power Filter Based Single Phase P-Q Theory , 2019, 2019 8th International Conference on Renewable Energy Research and Applications (ICRERA).

[10]  Ki-Bum Park,et al.  Weight Minimization of LCL Filters for High-Power Converters: Impact of PWM Method on Power Loss and Power Density , 2017, IEEE Transactions on Industry Applications.

[11]  Wei Zhang,et al.  Analysis and control of a reduced switch hybrid active power filter , 2016 .

[12]  Zhen Liu,et al.  A design method of LCL-filter for three-phase shunt active power filter , 2019 .

[13]  Cz. Radomski Analysis of Vienna rectifier , 2005 .

[14]  G. Griva,et al.  Shunt active power filter implementation for induction heating applications , 2005, Twentieth Annual IEEE Applied Power Electronics Conference and Exposition, 2005. APEC 2005..

[15]  G.W. Chang,et al.  A novel reference compensation current strategy for shunt active power filter control , 2004, IEEE Transactions on Power Delivery.

[16]  Liu Yu-hang,et al.  The research of three phase four wire active power filter on small independent micro-grid , 2016, 2016 China International Conference on Electricity Distribution (CICED).

[17]  Pradip Kumar Sadhu,et al.  An Exclusive Design of EMI-RFI Suppressor for Modified Half Bridge Inverter Fitted Induction Heating Equipment , 2015 .

[18]  Ranjan Kumar Behera,et al.  Real-Time Implementation of Shunt Active Power Filter With Reduced Sensors , 2020, IEEE Transactions on Industry Applications.

[19]  Sakorn Po-Ngam The simplified control of three-phase four-leg shunt active power filter for harmonics mitigation, load balancing and reactive power compensation , 2014, 2014 11th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology (ECTI-CON).

[20]  Shailendra Jain,et al.  Control Strategies of Shunt Active Power Filter , 2018 .

[21]  P. Sadhu,et al.  Design and Analysis of Series Resonant Inverter-Based Induction Heating Equipment Employing Power Factor Correction for Harmonic Attenuation , 2020 .

[22]  F. Blaabjerg,et al.  Performance Improvement of Shunt Active Power Filter With Dual Parallel Topology , 2007, IEEE Transactions on Power Electronics.