Interobserver reproducibility of the assessment of severity of complaints, grip strength, and pressure pain threshold in patients with lateral epicondylitis.

OBJECTIVE To evaluate the interobserver reproducibility of the assessment of severity of complaints, grip strength, and pressure pain threshold in patients with lateral epicondylitis in primary care. DESIGN Two physiotherapists assessed independently, and in randomized order, the severity of complaints scored on an 11-point numeric rating scale, pain-free grip strength, maximum grip strength, and pressure pain threshold. SETTING Primary care center in the Netherlands. PARTICIPANTS Fifty patients were assessed by both physiotherapists. INTERVENTIONS Not applicable. MAIN OUTCOME MEASURES Intraclass correlation coefficients (ICCs) and 95% confidence intervals (CIs) were calculated to assess interobserver reliability. The Bland and Altman method was used to assess interobserver agreement, which included calculation of the mean difference between the observers (d), the 95% CI for d, the standard deviation of the differences, and the 95% limits of agreement. Finally, the smallest detectable difference (SDD) was calculated. RESULTS The ICC for the severity of complaints was.90. The ICCs for the pain-free grip strength and maximum grip strength were.97 and.98, respectively. The pressure pain threshold showed a lower reliability (ICC=.77). The interobserver agreement for all outcome measures was good, but systematic differences in assessment between the physiotherapists were found for the maximum grip strength and pressure pain threshold. For pressure pain threshold, the SDD was clearly larger than the predefined acceptable difference of 10% of the total range of measurement. CONCLUSIONS The interobserver reliability of severity of complaints and grip strength was excellent, whereas the pressure pain threshold showed unsatisfactory reliability. Grip strength and overall assessment of the severity of complaints are useful and reliable measures for the assessment of lateral epicondylitis. Pain-free grip strength, in particular, is relatively easy to perform and has been shown to be associated with other measures of functional disability in patients with lateral epicondylitis. We, therefore, recommend the use of pain-free grip strength in both research and clinical practice.

[1]  J. Macdermid,et al.  Interrater reliability of pinch and grip strength measurements in patients with cumulative trauma disorders. , 1994, Journal of hand therapy : official journal of the American Society of Hand Therapists.

[2]  B. Vicenzino,et al.  Hyperalgesia in Tennis Elbow Patients , 1994 .

[3]  V. Mathiowetz,et al.  Reliability and validity of grip and pinch strength evaluations. , 1984, The Journal of hand surgery.

[4]  R. Oostendorp,et al.  Pain threshold in patients with rheumatoid arthritis and effect of manual oscillations. , 1999, Scandinavian journal of rheumatology.

[5]  J. Fleiss The design and analysis of clinical experiments , 1987 .

[6]  H. Vanharanta,et al.  Muscle function of the hand, wrist and forearm in chronic lateral epicondylitis , 1997 .

[7]  P. Stratford,et al.  Assessing Valid Change over Time in Patients with Lateral Epicondylitis at the Elbow , 1994 .

[8]  T. Sand,et al.  Pressure algometry in healthy subjects: inter-examiner variability. , 1998, Scandinavian journal of rehabilitation medicine.

[9]  G. Guyatt,et al.  Measuring change over time: assessing the usefulness of evaluative instruments. , 1987, Journal of chronic diseases.

[10]  G. Delaney,et al.  INTER- AND INTRA-RATER RELIABILITY OF THE PRESSURE THRESHOLD METER IN MEASUREMENT OF MYOFASCIAL TRIGGER POINT SENSITIVITY , 1993, American journal of physical medicine & rehabilitation.

[11]  M. Yaffe,et al.  Diagnosing and treating lateral epicondylitis. , 1994, Canadian family physician Medecin de famille canadien.

[12]  L. Bouter,et al.  Effectiveness of corticosteroid injections versus physiotherapy for treatment of painful stiff shoulder in primary care: randomised trial , 1998, BMJ.

[13]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.

[14]  B. Jaeger,et al.  Reliability of the pressure algometer as a measure of myofascial trigger point sensitivity , 1986, Pain.

[15]  I. Harman-boehm,et al.  Assessment of nonarticular tenderness and prevalence of fibromyalgia in hyperprolactinemic women. , 1993, The Journal of rheumatology.

[16]  E. Nussbaum,et al.  Reliability of clinical pressure-pain algometric measurements obtained on consecutive days. , 1998, Physical therapy.

[17]  E. Fess A method for checking Jamar dynamometer calibration , 1987 .

[18]  D. P. O'connor,et al.  Tender point sensitivity, range of motion, and perceived disability in subjects with neck pain. , 2000, The Journal of orthopaedic and sports physical therapy.

[19]  Fischer Aa Reliability of the pressure algometer as a measure of myofascial trigger point sensitivity. , 1987 .

[20]  P. Stratford Extensor carpi radialis tendonitis : A validation of selected outcome measures , 1987 .

[21]  P. Stratford,et al.  Generalizability of grip strength measurements in patients with tennis elbow. , 1989, Physical therapy.

[22]  P. Stratford Reliability: consistency or differentiating among subjects? , 1989, Physical therapy.

[23]  L. Bouter,et al.  Corticosteroid injections, physiotherapy, or a wait-and-see policy for lateral epicondylitis: a randomised controlled trial , 2002, The Lancet.

[24]  G. Littlejohn,et al.  Pressure pain threshold in pain-free subjects, in patients with chronic regional pain syndromes, and in patients with fibromyalgia syndrome. , 1993, Arthritis and rheumatism.

[25]  E. Andresen,et al.  Criteria for assessing the tools of disability outcomes research. , 2000, Archives of physical medicine and rehabilitation.

[26]  A. Feinstein,et al.  Clinical biostatistics: LIV. The biostatistics of concordance , 1981 .

[27]  A. Fischer Pressure algometry over normal muscles. Standard values, validity and reproducibility of pressure threshold , 1987, Pain.

[28]  D. Weiss,et al.  Interrater reliability and agreement of subjective judgments , 1975 .

[29]  B. Vicenzino,et al.  The initial effects of a cervical spine manipulative physiotherapy treatment on the pain and dysfunction of lateral epicondylalgia , 1996, Pain.

[30]  M. Besser,et al.  Validity of the Dexter Evaluation System's Jamar dynamometer attachment for assessment of hand grip strength in a normal population. , 2000, Journal of hand therapy : official journal of the American Society of Hand Therapists.

[31]  J M Bland,et al.  Statistical methods for assessing agreement between two methods of clinical measurement , 1986 .

[32]  P. Whincup,et al.  Randomised clinical trial of manipulative therapy and physiotherapy for persistent back and neck complaints: results of one year follow up. , 1992, BMJ.

[33]  A. Fischer Documentation of myofascial trigger points. , 1988, Archives of physical medicine and rehabilitation.

[34]  Ulf Lindblom,et al.  Pressure-pain threshold in human temporal region. Evaluation of a new pressure algometer , 1986, Pain.

[35]  Elaine Ewing Fess,et al.  Clinical assessment Recommendations , 1981 .

[36]  M. Stokes,et al.  Reliability of assessment tools in rehabilitation: an illustration of appropriate statistical analyses , 1998, Clinical rehabilitation.

[37]  A. Feinstein,et al.  THE BIOSTATISTICS OF CONCORDANCE , 1981 .