A Model for Uprating Transmission Lines by Using HTLS Conductors

This paper presents a new method for calculating tensions and sags on a tension section with different conductors on level and nonlevel spans of equal or unequal lengths and at any temperature, including the situation where the conductor temperature varies on the entire tension section. The model involves the application of high-temperature low-sag conductors on specific spans. As the conductor temperature and electrical current are intrinsically associated with ground clearances, a comparative study of steady-state ampacity models and a sensibility analysis with meteorological parameters were performed. This method results in a gain of ground clearance as well as horizontal tensions less than those calculated for the original line, depending on the type of floating dead end used. The results of a cost-benefit analysis prove very attractive, since the original conductors would not be discarded. Added to which, the large-scale installation of new towers is not necessary. The developed model represents, therefore, a significant contribution to low-cost uprating of transmission lines while, at the same time, avoiding the need to expand the transmission system.

[1]  I. Albizu,et al.  Methods for increasing the rating of overhead lines , 2005, 2005 IEEE Russia Power Tech.

[2]  Dennis Woodford,et al.  MAXIMIZING THE CAPABILITY OF EXISTING AC TRANSMISSION LINES , 2008 .

[3]  Friedrich Kiessling,et al.  Overhead Power Lines , 2003 .

[4]  T. Anderson,et al.  A new generation of high performance conductors , 2001, 2001 Power Engineering Society Summer Meeting. Conference Proceedings (Cat. No.01CH37262).

[5]  H. B. Dwight Sag Calculations for Transmission Lines , 1926, Transactions of the American Institute of Electrical Engineers.

[6]  D. C. Lawry,et al.  Increasing power transfer capability of existing transmission lines , 2003, 2003 IEEE PES Transmission and Distribution Conference and Exposition (IEEE Cat. No.03CH37495).

[7]  S. Sakabe,et al.  Development of Extremely-Low-Sag Invar Reinforced ACSR (XTACIR) , 1981, IEEE Transactions on Power Apparatus and Systems.

[8]  M. Keshavarzian,et al.  Sag and tension calculations for overhead transmission lines at high temperatures-modified ruling span method , 2000 .

[9]  H. B. White,et al.  Limitations of the ruling span method for overhead line conductors at high operating temperatures , 1999 .

[10]  J.R. Saenz,et al.  High-temperature conductors: a solution in the uprating of overhead transmission lines , 2001, 2001 IEEE Porto Power Tech Proceedings (Cat. No.01EX502).

[11]  G. N. Aleksandrov,et al.  A proposed design for the new Furnas 500 kV transmission lines-the High Surge Impedance Loading Line , 1999 .