Alteration of Surface EMG amplitude levels of five major trunk muscles by defined electrode location displacement.

Exact electrode positioning is vital for obtaining reliable results in Surface EMG. This study aimed at systematically assessing the influence of defined electrode shifts on measured Surface EMG amplitudes of trunk muscles in a group of 15 middle aged healthy male subjects. The following leftsided muscles were investigated: rectus abdominis muscle, internal and external oblique abdominal muscles, lumbar multifidus muscle, and longissimus muscle. In addition to the recommended electrode positions, extra electrodes were placed parallel to these and along muscle fiber direction. Measurements were performed under isometric conditions in upright body position. Gradually changing, but defined loads were applied considering subject's upper body weight. For the abdominal muscles amplitude differences varied considerably depending on load level, magnitude, and direction. For both back muscles amplitudes dropped consistently but rather little for parallel electrode displacements. However, for the longissimus muscle a caudal electrode shift resulted in an amplitude increase of similar extent and independent from load level. Influence of electrode position variations can be proven for all trunk muscles but are more evident in abdominal than back muscles. Those muscle-specific effects confirm the necessity for an exact definition of electrode positioning to allow comparisons between individual subjects, groups of subjects, and studies.

[1]  Dario Farina,et al.  Surface EMG crosstalk between knee extensor muscles: Experimental and model results , 2002, Muscle & nerve.

[2]  Dario Farina,et al.  Standardising surface electromyogram recordings for assessment of activity and fatigue in the human upper trapezius muscle , 2002, European Journal of Applied Physiology.

[3]  Christoph Anders,et al.  Evaluation of the EMG-force relationship of trunk muscles during whole body tilt. , 2008, Journal of biomechanics.

[4]  T. Masuda,et al.  Innervation zones in the back muscles investigated by multichannel surface EMG. , 1995, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[5]  F. Lacquaniti,et al.  Motor patterns in human walking and running. , 2006, Journal of neurophysiology.

[6]  P. A. Lynn,et al.  Influence of electrode geometry on bipolar recordings of the surface electromyogram , 1978, Medical and Biological Engineering and Computing.

[7]  C. Richardson,et al.  Muscle fibre orientation of abdominal muscles and suggested surface EMG electrode positions. , 1998, Electromyography and clinical neurophysiology.

[8]  A. Rainoldi,et al.  Innervation zones location and optimal electrodes position of obliquus internus and obliquus externus abdominis muscles. , 2014, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[9]  Dario Farina,et al.  A novel approach for precise simulation of the EMG signal detected by surface electrodes , 2001, IEEE Trans. Biomed. Eng..

[10]  H. Biedermann,et al.  Median frequency estimates of paraspinal muscles: reliability analysis. , 1990, Electromyography and clinical neurophysiology.

[11]  D. Farina,et al.  Geometrical factors in surface EMG of the vastus medialis and lateralis muscles. , 2000, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[12]  Travis W. Beck,et al.  The influence of electrode shift over the innervation zone and normalization on the electromyographic amplitude and mean power frequency versus isometric torque relationships for the vastus medialis muscle , 2008, Journal of Neuroscience Methods.

[13]  T. Zachry,et al.  EMG sensor location: Does it influence the ability to detect differences in muscle contraction conditions? , 2006, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[14]  J. Holle,et al.  External oblique abdominal muscle: A new look on its blood supply and innervation , 1999, The Anatomical record.

[15]  G V Dimitrov,et al.  Calculation of extracellular potentials produced by an inclined muscle fibre at a rectangular plate electrode. , 1999, Medical engineering & physics.

[16]  H. J. Hermens,et al.  Effects of electrode dislocation on electromyographic activity and relative rest time: Effectiveness of compensation by a normalisation procedure , 2006, Medical and Biological Engineering and Computing.

[17]  D. Larson,et al.  Rectus abdominis muscle innervation: implications for TRAM flap elevation. , 1995, Plastic and reconstructive surgery.

[18]  H. Hermens,et al.  European recommendations for surface electromyography: Results of the SENIAM Project , 1999 .

[19]  W. Kingery,et al.  The lumbar multifidus muscle in polysegmentally innervated. , 2000, Electromyography and clinical neurophysiology.

[20]  Ulrich Zwiener,et al.  Quantifizierung von Artefakten im Oberflächen-EMG zur Validisierung der unteren Grenzfrequenz bei klinisch-physiologischen Untersuchungen , 1991 .

[21]  K. Manjunath,et al.  The tendinous intersections of rectus abdominis muscle. , 2008 .

[22]  Dick F Stegeman,et al.  Surface EMG mapping of the human trapezius muscle: the topography of monopolar and bipolar surface EMG amplitude and spectrum parameters at varied forces and in fatigue , 2000, Clinical Neurophysiology.

[23]  M. Solomonow,et al.  Surface and wire EMG crosstalk in neighbouring muscles. , 1994, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[24]  D. Winter,et al.  Anticipatory control of upper body balance during human locomotion , 1994 .

[25]  H J Hermens,et al.  Evaluating the effect of electrode location on surface EMG amplitude of the m. erector spinae p. longissimus dorsi. , 2009, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[26]  Jeffrey R Stout,et al.  Electrode placement over the innervation zone affects the low-, not the high-frequency portion of the EMG frequency spectrum. , 2009, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[27]  F Lacquaniti,et al.  Spinal cord maps of spatiotemporal alpha-motoneuron activation in humans walking at different speeds. , 2006, Journal of neurophysiology.

[28]  Dario Farina,et al.  Influence of anatomical, physical, and detection-system parameters on surface EMG , 2002, Biological Cybernetics.