Assessment of human annoyance under flicker condition

The international standard EN 61000–4–15 gives functional and design specifications for the Flickermeter currently used to evaluate the flicker severity, as defined in the International Electrotechnical Vocabulary. That instrument doesn't work properly if light sources different than incandescent-filament one are considered. This paper is aimed at presenting a step towards an innovative Flickermeter which is able to account a larger variety of luminous sources. In particular, the goal of this study is to find a new method to define the human annoyance under flicker condition, based on the measurement of the pupil size in presence of different flicker stimuli. The design and characterization of an automatic system able to generate flicker and measure the pupil size will be presented. In addition, the results obtained on human subject will be illustrated.

[1]  Lorenzo Peretto,et al.  A Measurement System for the Analysis of the Response of the Human Eye to the Light Flicker , 2007, IEEE Transactions on Instrumentation and Measurement.

[2]  Daniele Gallo,et al.  Light flicker prediction based on voltage spectral analysis , 2001, 2001 IEEE Porto Power Tech Proceedings (Cat. No.01EX502).

[3]  A.E. Emanuel,et al.  The Response of Fluorescent Lamp with Magnetic Ballast to Voltage Distortion , 1997 .

[4]  L. Peretto,et al.  A simple lamp-eye-brain model for flicker observations , 2004, IEEE Transactions on Power Delivery.

[5]  Z. Hanzelka,et al.  Application of neural networks to voltage fluctuations measurement-a proposal for a new flickermeter , 2004, 2004 11th International Conference on Harmonics and Quality of Power (IEEE Cat. No.04EX951).

[6]  J.C. Lavandero,et al.  Instrumentation and methodology for revision of European flicker threshold , 2002, 10th International Conference on Harmonics and Quality of Power. Proceedings (Cat. No.02EX630).

[7]  Maria Gabriella Masi,et al.  New Basis for the Development of the next-generation Flickermeters , 2010, 2010 IEEE International Workshop on Applied Measurements for Power Systems.

[8]  Lorenzo Peretto,et al.  Theoretical Analysis of the Physiologic Mechanism of Luminous Variation in Eye-Brain System , 2007, IEEE Transactions on Instrumentation and Measurement.

[9]  Carmine Landi,et al.  Design and Calibration of an Objective Flickermeter , 2006, IEEE Transactions on Instrumentation and Measurement.

[10]  Maria Gabriella Masi,et al.  A pupil size measurement system for the analysis of the impact of flicker on human being , 2008 .