Evaluation of parallel factor analysis for the resolution of kinetic data by diode-array high-performance liquid chromatography

The PARAFAC algorithm for factor analysis of three or higher way datasets is summarised. A series of simulations of kinetic profiles of two-way diode-array HPLC data is described. A three-phase reaction system of reactant, intermediate and product is used to illustrate the method, each closely eluting and with similar spectra based on experimental HPLC with diode-array detection of chlorophyll degradation products. A kinetic parameter is varied to change the relative concentration of the intermediate in each series of simulations. Several indices of quality of reconstruction are introduced. It is concluded that the number of factors used to model the data is crucial to the quality of reconstruction. A good approach is first to use fewer factors than are expected, then increasing the number until each elution profile shows a single maximum.

[1]  Multivariate calibration of reversed-phase chromatographic systems. Some designs based on three-way data analysis , 1990 .

[2]  R. Brereton,et al.  THE USE OF LIQUID CHROMATOGRAPHY‐MASS SPECTROMETRY TO MONITOR THE ALLOMERIZATION REACTIONS OF CHLOROPHYLL a and PHEOPHYTIN a:m IDENTIFICATION OF THE ALLOMERS OF PHEOPHYTIN a , 1993 .

[3]  Michael L. Myrick,et al.  Single-Measurement Excitation/Emission Matrix Spectrofluorometer for Determination of Hydrocarbons in Ocean Water. 2. Calibration and Quantitation of Naphthalene and Styrene , 1996 .

[4]  Age K. Smilde,et al.  Three-way analyses problems and prospects , 1992 .

[5]  R. Cattell The three basic factor-analytic research designs-their interrelations and derivatives. , 1952, Psychological bulletin.

[6]  B. Grung,et al.  Detection and quantification of embedded minor analytes in three-way multicomponent profiles by evolving projections and internal rank annihilation , 1995 .

[7]  Age K. Smilde,et al.  Multicomponent Determination of Chlorinated Hydrocarbons Using a Reaction-Based Chemical Sensor. 3. Medium-Rank Second-Order Calibration with Restricted Tucker Models , 1994 .

[8]  R. Harshman,et al.  PARAFAC: parallel factor analysis , 1994 .

[9]  Ben C. Mitchell,et al.  An empirical comparison of resolution methods for three-way arrays , 1993 .

[10]  R. Brereton,et al.  Resolvability indices and variable selection in factor analysis of diode-array high-performance liquid chromatography: development of an approach for multi-peak clusters and application to mixtures of chlorophyll degradation products , 1995 .

[11]  J. Leeuw,et al.  Principal component analysis of three-mode data by means of alternating least squares algorithms , 1980 .

[12]  Stephen P. Gurden,et al.  Resolution of multicomponent mixture spectra in mid-infrared spectroscopy using spherical projection factor analysis: application to real data including a six-component mixture set , 1996 .

[13]  H. Law Research methods for multimode data analysis , 1984 .

[14]  Forrest W. Young,et al.  Component models for three-way data: An alternating least squares algorithm with optimal scaling features , 1980 .

[15]  J. Kruskal More factors than subjects, tests and treatments: An indeterminacy theorem for canonical decomposition and individual differences scaling , 1976 .

[16]  Problems of Measuring Changes in Poverty over Time: The Case of Uganda 1989–92 , 1996 .

[17]  Rasmus Bro,et al.  Enzymatic browning of vegetables. Calibration and analysis of variance by multiway methods , 1996 .

[18]  R. Bro Multiway calibration. Multilinear PLS , 1996 .

[19]  Stephen P. Gurden,et al.  Resolution of infrared spectra of mixtures of potential organic workplace pollutants by factor analysis , 1994 .

[20]  D. Burdick An introduction to tensor products with applications to multiway data analysis , 1995 .