Mechanical forces as predictors of healing during tibial lengthening by distraction osteogenesis.

Direct axial loads were measured weekly during a 15% left tibial lengthening in 21 skeletally mature dogs using three in-line load cells mounted between the rings of an Ilizarov external fixator. The loads increased linearly over time to a maximum at the end of distraction (Week 4). The metaphyseal lengthening sites (mean, 155 N) generated significantly higher loads than diaphyseal sites (mean, 111 N). Stress was calculated by dividing measured load by the computed tomographic-measured cross-sectional area of each distraction osteogenesis site; the metaphyseal and diaphyseal groups demonstrated equal stress at each time point with a maximum of 47 N/cm2 at the end of distraction. Six premature consolidations occurred that demonstrated loads significantly greater than 200 N by Week 2 of distraction. Three nonunions occurred that had significantly lower loads measured by Week 3 of distraction (mean, 60 N or 26 N/cm2).

[1]  J. Miller,et al.  Biomechanical factors in the metaphyseal- and diaphyseal-lengthening osteotomy. An experimental and theoretic analysis in the ovine tibia. , 1990, Clinical orthopaedics and related research.

[2]  J. Kenwright,et al.  The timing of distraction of an osteotomy. , 1990, The Journal of bone and joint surgery. British volume.

[3]  E Schneider,et al.  Stiffness characteristics of the circular Ilizarov device as opposed to conventional external fixators. , 1990, Journal of biomechanical engineering.

[4]  G J Verkerke,et al.  Design of a Load Cell for the Wagner Distractor , 1989, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[5]  J. Aronson,et al.  The histology of distraction osteogenesis using different external fixators. , 1989, Clinical orthopaedics and related research.

[6]  J. Aronson,et al.  Mechanical Induction of Osteogenesis: The Importance of Pin Rigidity , 1988, Journal of pediatric orthopedics.

[7]  E Y Chao,et al.  The early healing of tibial osteotomies stabilized by one-plane or two-plane external fixation. , 1987, The Journal of bone and joint surgery. American volume.

[8]  N. Nishimura Serial strain gauge measurement of bone healing in hoffmann® external fixation. , 1984, Orthopedics.

[9]  J. Leong,et al.  Viscoelastic behavior of tissue in leg lengthening by distraction. , 1979, Clinical orthopaedics and related research.

[10]  J. Kenwright,et al.  Response of the growth plate to distraction close to skeletal maturity. Is fracture necessary? , 1990, Clinical orthopaedics and related research.

[11]  J J Thomason,et al.  Force and stiffness changes during Ilizarov leg lengthening. , 1990, Clinical orthopaedics and related research.

[12]  T. Kristiansen,et al.  Mechanical evaluation of external fixators used in limb lengthening. , 1990, Clinical orthopaedics and related research.

[13]  J. Aronson,et al.  Factors influencing the choice of external fixation for distraction osteogenesis. , 1990, Instructional course lectures.

[14]  R. Emery,et al.  EPIPHYSEAL DISTRACTION MONITORED BY STRAIN GAUGES , 1989 .

[15]  E Y Chao,et al.  Theoretical analysis of fracture healing monitoring with external fixators. , 1988, Engineering in medicine.