Thermal management of a 3D chip stack using a liquid interface to a synthetic jet cooled spreader

The present investigation focuses on the design of a unique liquid interface thermal management solution for a 3D chip stack that is embedded within a cavity, in a heat spreader cooled by an array of synthetic jet actuators. The heat sink module was previously reported by the authors, who achieved an overall heat transfer coefficient of ∼70 W/m2.K. The radial heat sink exploits enhanced, small-scale heat transfer that is affected by a central array of synthetic jet actuators. This approach is very effective due to the short radial thermal path of the cooling air along the fins which couples rapid, time-periodic entrainment and ejection of cool and heated air, respectively to increase the local heat transfer coefficient on the air-side. The key focus of this paper is the numerical simulation of the dielectric liquid interface used to efficiently transmit the heat from the high power 3D stacked electronics to the heat sink base. The coupled natural convection in the fluid and conduction in solid spreaders sandwiched between the tiers of the stack form a novel efficient, passive and scalable thermal management solution.

[1]  A. Bar-Cohen,et al.  POOL AND FLOW BOILING IN NARROW GAPS - APPLICATION TO 3D CHIP STACKS , 2008 .

[2]  Weiwei Yang,et al.  Three-Dimensional Numerical Study of Natural Convective Heat Transfer of Liquid in a Cubic Enclosure , 2005 .

[3]  Guang-Fa Tang,et al.  Interaction between discrete heat sources in horizontal natural convection enclosures , 2002 .

[4]  Yogendra Joshi,et al.  Natural Convection Heat Transfer From an Array of Rectangular Protrusions in an Enclosure Filled With Dielectric Liquid , 1994 .

[5]  Theodore J. Heindel,et al.  Conjugate natural convection from an array of discrete heat sources: Part 2 — A numerical parametric study , 1995 .

[6]  M. K. Iyer,et al.  Thermal characterization of vias using compact models , 2000, Proceedings of 3rd Electronics Packaging Technology Conference (EPTC 2000) (Cat. No.00EX456).

[7]  C. P. Tso,et al.  3-D numerical analysis of natural convective liquid cooling of a 3×3 heater array in rectangular enclosures , 1999 .

[8]  N. Djilali,et al.  Natural Convection in an Enclosure with Distributed Heat Sources , 2006 .

[9]  T. J. Heindel,et al.  96/03382 - Conjugate natural convection from an array of discrete heat sources: Part 1 — Two- and three-dimensional model validation , 1996 .

[10]  H. Reichl,et al.  Forced convective interlayer cooling in vertically integrated packages , 2008, 2008 11th Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems.

[11]  Theodore J. Heindel,et al.  Conjugate natural convection from an array of discrete heat sources: Part 1 Two- and three-dimensi , 1995 .

[12]  D. Gerty,et al.  Development of a prototype thermal management solution for 3-D stacked chip electronics by interleaved solid spreaders and synthetic jets , 2007, 2007 13th International Workshop on Thermal Investigation of ICs and Systems (THERMINIC).

[13]  Y. Joshi,et al.  Liquid Immersion Cooling of a Substrate-Mounted Protrusion in a Three-Dimensional Enclosure: The Effects of Geometry and Boundary Conditions , 1994 .

[14]  D. Rubenstein,et al.  Introduction to heat transfer , 2022 .