Targeted-Microbubble Binding Selectively to GPIIb IIIa Receptors of Platelet Thrombi

Schumann PA, Christiansen JP, Quigley R, et al. Targeted-microbubble binding selectively to GPIIb IIIa receptors of platelet thrombi. Invest Radiol 2002;37:587–593. Rationale and Objectives.New targeted microbubbles directed to the GPIIb IIIa receptor have been developed. The objective was to determine whether targeting microbubbles to clots would enhance ultrasound imaging. Systematic studies were designed to determine whether in vitro methodology is an acceptable predictor of in vivo efficacy. Materials and Methods.Bioconjugate ligands were inserted into lipid-coated membranes of perfluorocarbon gas microbubbles and binding studies performed on activated platelets immobilized on cell culture plates. Targeted microbubble binding to clots in a flow through chamber was also assessed. Finally, microbubble binding studies on arteriolar and venular clots in a mouse cremasteric muscle model were conducted. Results.Binding studies on platelet-immobilized plates demonstrated an affinity for targeted microbubbles versus untargeted microbubbles. Semiquantitative light obscuration techniques helped to measure extent of targeted microbubble binding. Targeted microbubbles similarly bound to platelet clots in the flow model. Finally, studies in the mouse model confirmed binding of targeted microbubbles in both venules and arterioles. Conclusion.The use of receptor selective targeted microbubbles improved binding to vascular thrombi in both in vitro and in vivo settings.

[1]  S. Rajagopalan,et al.  Ultrasound-mediated transfection of canine myocardium by intravenous administration of cationic microbubble-linked plasmid DNA. , 2002, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[2]  K. Ley,et al.  Ultrasound Assessment of Inflammation and Renal Tissue Injury With Microbubbles Targeted to P-Selectin , 2001, Circulation.

[3]  S. Kaul,et al.  Noninvasive Ultrasound Imaging of Inflammation Using Microbubbles Targeted to Activated Leukocytes , 2000, Circulation.

[4]  S. Kaul,et al.  Microbubble persistence in the microcirculation during ischemia/reperfusion and inflammation is caused by integrin- and complement-mediated adherence to activated leukocytes. , 2000, Circulation.

[5]  E Krupinski,et al.  The use of a thrombus-specific ultrasound contrast agent to detect thrombus in arteriovenous fistulae. , 2000, Investigative radiology.

[6]  N. Pandian,et al.  Enhanced visualization of intravascular and left atrial appendage thrombus with the use of a thrombus-targeting ultrasonographic contrast agent (MRX-408A1): In vivo experimental echocardiographic studies. , 1999, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[7]  M. Wheatley,et al.  Preparation and characterization of hollow microcapsules for use as ultrasound contrast agents , 1999 .

[8]  B. Lüderitz,et al.  Imaging of thrombi and assessment of left atrial appendage function: a prospective study comparing transthoracic and transoesophageal echocardiography , 1999, Heart.

[9]  Y Wu,et al.  Binding and lysing of blood clots using MRX-408. , 1998, Investigative radiology.

[10]  M. Fishbein,et al.  Enhancement of thrombolysis in vivo without skin and soft tissue damage by transcutaneous ultrasound. , 1998, Thrombosis research.

[11]  S. Wickline,et al.  Development of a novel site-targeted ultrasonic contrast agent , 1997 .

[12]  J. G. Miller,et al.  A novel site-targeted ultrasonic contrast agent with broad biomedical application. , 1996, Circulation.

[13]  F Forsberg,et al.  Parenchymal enhancement and tumor visualization using a new sonographic contrast agent. , 1995, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[14]  S. Wickline,et al.  Quantitative intravascular ultrasound. Demonstration using a novel site targeted acoustic contrast agent , 1995, 1995 IEEE Ultrasonics Symposium. Proceedings. An International Symposium.

[15]  K. Tachibana,et al.  Albumin microbubble echo-contrast material as an enhancer for ultrasound accelerated thrombolysis. , 1995, Circulation.

[16]  Feng Yan,et al.  BR1: A New Ultrasonographic Contrast Agent Based on Sulfur Hexafluoride-Filled Microbubbles , 1995, Investigative radiology.

[17]  M. Wheatley,et al.  Surfactant-stabilized microbubbles as ultrasound contrast agents : stability study of Span 60 and Tween 80 mixtures using a Langmuir trough , 1993 .

[18]  E. Unger,et al.  Nitrogen-filled liposomes as a vascular US contrast agent: preliminary evaluation. , 1992, Radiology.

[19]  Dick W. Slaaf,et al.  Concentration and Velocity Profiles of Blood Cells in the Microcirculation , 1992 .

[20]  R. Lange,et al.  Chemical shift artifact: dependence on shape and orientation of the lipid-water interface. , 1991, Radiology.

[21]  R S Reneman,et al.  Wall shear rate in arterioles in vivo: least estimates from platelet velocity profiles. , 1988, The American journal of physiology.

[22]  F J Ten Cate,et al.  Two-dimensional contrast echocardiography. I. In vitro development and quantitative analysis of echo contrast agents. , 1984, Journal of the American College of Cardiology.

[23]  W. Kannel,et al.  Epidemiologic features of chronic atrial fibrillation: the Framingham study. , 1982, The New England journal of medicine.

[24]  R Gramiak,et al.  Echocardiography of the aortic root. , 1968, Investigative radiology.