Data fusion for catheter tracking using Kalman filtering: applications in robot-assisted catheter insertion

X-ray image guided angioplasty is a minimally invasive procedure that involves the insertion of a catheter into a blood vessel to remove blockages to blood flow. There are several issues associated with conventional angioplasty which cause risks for the patient (damage to blood vessels, dislodging plaques, etc.) and difficulties for the clinician (X-ray exposure, fatigue, etc.). Autonomous or semi-autonomous robot-assisted catheter insertion is a solution that can reduce these problems substantially. To perform autonomous catheter insertion, closed-loop position control of the distal tip of the catheter is required during insertion. Therefore accurate real-time position feedback is needed for this purpose. We have developed a real-time image processing algorithm for catheter tip position tracking which has an acceptable performance but is sensitive to X-ray image artifacts caused by bones and dense tissues. A magnetic tracking system (MTS) is another modality that has also been used for catheter tip position tracking, but it is sensitive to external electromagnetic interferences and ferromagnetic material. Combining the measurement data provided by both imaging and magnetic sensors can compensate for the deficiencies of each and can also improve the robustness of catheter tip position tracking. We have developed a Kalman filter based sensor fusion scheme to overcome deficiencies of both of these methods and create a reliable real-time tracking of a catheter tip. Experiments have been performed by inserting a guide catheter into a model of the vasculature. The method has been tested in presence of occlusion in the images and also electromagnetic interference.

[1]  Hui Zhang,et al.  Freehand 3D ultrasound calibration using an electromagnetically tracked needle , 2006, SPIE Medical Imaging.

[2]  James A. Gehl,et al.  Comparison of X‐ray fluoroscopy and interventional magnetic resonance imaging for the assessment of coronary artery stenoses in swine , 2005, Magnetic resonance in medicine.

[3]  Rajnikant V. Patel,et al.  Autonomous robot-assisted active catheter insertion using image guidance , 2007, 2007 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[4]  Rajnikant V. Patel,et al.  Autonomous Image-Guided Robot-Assisted Active Catheter Insertion , 2008, IEEE Transactions on Robotics.

[5]  Rajnikant V. Patel,et al.  Bilateral telemanipulation of a flexible catheter in a constrained environment , 2008, 2008 IEEE International Conference on Robotics and Automation.

[6]  Zhengyou Zhang,et al.  A Flexible New Technique for Camera Calibration , 2000, IEEE Trans. Pattern Anal. Mach. Intell..

[7]  Emanuele Trucco,et al.  Introductory techniques for 3-D computer vision , 1998 .

[8]  H. B. Mitchell,et al.  Multi-Sensor Data Fusion: An Introduction , 2007 .

[9]  Holger Timinger,et al.  Modality-integrated magnetic catheter tracking for x-ray vascular interventions. , 2005, Physics in medicine and biology.

[10]  J. Jayender,et al.  Image processing algorithms for real-time tracking and control of an active catheter , 2007, 2007 European Control Conference (ECC).

[11]  E Klotz,et al.  Three-dimensional reconstruction of high contrast objects using C-arm image intensifier projection data. , 1999, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.

[12]  Junbin Gao,et al.  Some remarks on Kalman filters for the multisensor fusion , 2002, Inf. Fusion.

[13]  F Arai,et al.  Autonomous catheter insertion system using magnetic motion capture sensor for endovascular surgery , 2007, The international journal of medical robotics + computer assisted surgery : MRCAS.

[14]  C.T. Wang,et al.  Novel method for correction of x-ray fluoroscopic image , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[15]  Yaakov Bar-Shalom,et al.  The Effect of the Common Process Noise on the Two-Sensor Fused-Track Covariance , 1986, IEEE Transactions on Aerospace and Electronic Systems.