Fluorescence staining and flow cytometry for monitoring microbial cells.

Large numbers of microbiological samples are analysed annually using traditional culture-based techniques. These techniques take hours to days to yield a result, are tedious and are not suitable for non-culturable microorganisms. Further, culture-based techniques do not provide real-time information on the physiological status of the organism in situ which is important in the industrial manufacture of many microbial products. Flow cytometry offers the prospect of real-time microbial analysis of individual microorganisms, without dependency on microbial culture. However, flow cytometry has not been extensively used as a tool for routine microbial analysis. This has been mainly due to the high cost and complexity of instrumentation, the need for trained flow cytometrists and the lack of assay kits with appropriate biological reagents for specific applications. Many modern instruments are now relatively simple to operate, due to improvements in the user-interface, and no longer need a specialist operator. However, most cytometers are still reliant on analogue technology first developed 20-30 years ago. The incorporation of modern, solid state opto-electronics combined with micro-fabrication and digital signal processing technology offers the prospect of simple to use, low cost and robust instruments suitable for microbial analyses. Advances are being made in the development of a range of biological reagents and these are now being formulated into simple to use kits for microbiological applications. Currently, these kits are largely restricted to simple analyses, for example to assay for total or viable numbers of microorganisms present. However, technologies are available to selectively label specific types of microorganisms. For example, fluorescent antibodies can be used to label microorganisms according to expression of particular antigens, fluorescent in situ hybridisation to label according to phylogeny and fluorogenic enzymatic substrates to label according to expression of specific enzyme activities. Reagents are also available that stain viruses sufficiently brightly to enable their direct detection in environments such as sea water. Microorganisms need to be detected in a variety of different matrices (e.g., water, mud, food, and beverages) and these matrices may be highly variable in nature (e.g., tap water compared to river water). Many matrices have high background autofluorescence (e.g., algae and minerals in water samples) or may bind non-specifically to the fluorescent biological reagents used (e.g., protein micelles in milk). Formulation of biological reagents and sample pre-treatments are critical to the development of suitable microbiological assays. Here, developments in instrumentation and biological reagents for microbiological applications are reviewed with specific examples from environmental or industrial microbiology. The broader considerations for the development of microbial assays for flow cytometry are also considered.

[1]  A. Howgrave-Graham,et al.  Application of the Fluorescent-Antibody Technique for the Detection of Sphaerotilus natans in Activated Sludge , 1988, Applied and environmental microbiology.

[2]  M H Zwietering,et al.  Characterization of uptake and hydrolysis of fluorescein diacetate and carboxyfluorescein diacetate by intracellular esterases in Saccharomyces cerevisiae, which result in accumulation of fluorescent product , 1995, Applied and environmental microbiology.

[3]  Douglas B. Kell,et al.  Rapid assessment of bacterial viability and vitality by rhodamine 123 and flow cytometry , 1992 .

[4]  H. Paerl,et al.  Immunofluorescence detection and characterization of N2-fixing microorganisms from aquatic environments , 1990 .

[5]  K. Schleifer,et al.  Phylogenetic identification and in situ detection of individual microbial cells without cultivation. , 1995, Microbiological reviews.

[6]  R. Jepras,et al.  Development of a robust flow cytometric assay for determining numbers of viable bacteria , 1995, Applied and environmental microbiology.

[7]  D Marie,et al.  Application of the novel nucleic acid dyes YOYO-1, YO-PRO-1, and PicoGreen for flow cytometric analysis of marine prokaryotes , 1996, Applied and environmental microbiology.

[8]  N. Ashbolt,et al.  Detection of specific microorganisms in environmental samples using flow cytometry. , 1994, Methods in cell biology.

[9]  S. Molin,et al.  Application of a strain-specific rRNA oligonucleotide probe targeting Pseudomonas fluorescens Ag1 in a mesocosm study of bacterial release into the environment , 1995, Applied and environmental microbiology.

[10]  C. Edwards,et al.  Rapid, automated separation of specific bacteria from lake water and sewage by flow cytometry and cell sorting , 1993, Applied and environmental microbiology.

[11]  L. Mcbride,et al.  Detection of HIV-1 DNA and messenger RNA in individual cells by PCR-driven in situ hybridization and flow cytometry. , 1993, Science.

[12]  Thusitha S. Gunasekera,et al.  A Flow Cytometry Method for Rapid Detection and Enumeration of Total Bacteria in Milk , 2000, Applied and Environmental Microbiology.

[13]  N. Ashbolt,et al.  The use of a ribosomal RNA targeted oligonucleotide probe for fluorescent labelling of viable Cryptosporidiumparvum oocysts , 1998, Journal of applied microbiology.

[14]  K. Schleifer,et al.  In situ identification of bacteria in drinking water and adjoining biofilms by hybridization with 16S and 23S rRNA-directed fluorescent oligonucleotide probes , 1993, Applied and environmental microbiology.

[15]  D. Lloyd,et al.  Vigour, vitality and viability of microorganisms , 1995 .

[16]  D. Kell,et al.  Influence of Viable Cells on the Resuscitation of Dormant Cells in Micrococcus luteus Cultures Held in an Extended Stationary Phase: the Population Effect , 1994, Applied and environmental microbiology.

[17]  D. Veal,et al.  Observation of single-cell fluorescence spectra in laser flow cytometry. , 1996, Cytometry.

[18]  C. Barardi,et al.  Development of a rapid and sensitive quantitative assay for rotavirus based on flow cytometry. , 1998, Journal of virological methods.

[19]  M. Cranfield,et al.  Evaluation of commercial enzyme immunoassay (EIA) and immunofluorescent antibody (FA) test kits for detection of Cryptosporidium oocysts of species other than Cryptosporidium parvum. , 1996, The American journal of tropical medicine and hygiene.

[20]  T. D. Brock The study of microorganisms in situ progress and problems , 1987 .

[21]  H. Yu,et al.  Comparative studies of magnetic particle-based solid phase fluorogenic and electrochemiluminescent immunoassay. , 1998, Journal of immunological methods.

[22]  A. Gehring,et al.  Enzyme-linked immunomagnetic electrochemical detection of Salmonella typhimurium. , 1996, Journal of immunological methods.

[23]  R. L. Wolfe,et al.  Evaluation of Immunomagnetic Separation for Recovery of Infectious Cryptosporidium parvum Oocysts from Environmental Samples , 1999, Applied and Environmental Microbiology.

[24]  N. Ashbolt,et al.  Rapid method for fluorescent in situ ribosomal RNA labelling of Cryptosporidium parvum , 1998, Journal of applied microbiology.

[25]  R. Burns,et al.  Flow cytometry as a means of enumerating bacteria introduced into soil , 1991 .

[26]  D. Veal,et al.  Simple and rapid measurement of Cryptosporidium excystation using flow cytometry. , 1997, International journal for parasitology.

[27]  Richard P. Haugland,et al.  Handbook of fluorescent probes and research chemicals , 1996 .

[28]  M. Laurent,et al.  Use of flow cytometry in oenology to analyse yeasts , 1994 .

[29]  D. Veal,et al.  Flow cytometry and cell sorting for yeast viability assessment and cell selection , 1998, Yeast.

[30]  D. Veal,et al.  A Flow Cytometric Method for Rapid Selection of Novel Industrial Yeast Hybrids , 1998, Applied and Environmental Microbiology.

[31]  J. S. Pierce,et al.  INSTITUTE OF BREWING: ANALYSIS COMMITTEE MEASUREMENT OF YEAST VIABILITY , 1970 .

[32]  C. Donnelly,et al.  Flow cytometry for automated analysis of milk containing Listeria monocytogenes. , 1988, Journal - Association of Official Analytical Chemists.

[33]  G. Stelma,et al.  Comparison of methods for detection and enumeration of airborne microorganisms collected by liquid impingement , 1996, Applied and environmental microbiology.

[34]  K. Williams,et al.  Comparison of Cryptosporidium-specific and Giardia-specific monoclonal antibodies for monitoring water samples , 1999 .

[35]  S. Langsrud,et al.  Flow cytometry for rapid assessment of viability after exposure to a quaternary ammonium compound. , 1996, The Journal of applied bacteriology.

[36]  Glen A. Tarran,et al.  Discrimination of marine phytoplankton species through the statistical analysis of their flow cytometric signatures , 1996 .

[37]  David Lloyd,et al.  Flow Cytometry in Microbiology , 1993, Springer London.

[38]  D. Vaulot,et al.  Enumeration and Cell Cycle Analysis of Natural Populations of Marine Picoplankton by Flow Cytometry Using the Nucleic Acid Stain SYBR Green I , 1997, Applied and environmental microbiology.

[39]  D. Lloyd,et al.  Flow cytometric monitoring of rhodamine 123 and a cyanine dye uptake by yeast during cider fermentation , 1996 .

[40]  C. Edwards,et al.  Survival of Staphylococcus aureus in lakewater monitored by flow cytometry. , 1994, Microbiology.

[41]  Lynne Boddy,et al.  Identification of Phytoplankton from Flow Cytometry Data by Using Radial Basis Function Neural Networks , 1999, Applied and Environmental Microbiology.

[42]  D. Kell,et al.  Flow cytometry and cell sorting of heterogeneous microbial populations: the importance of single-cell analyses. , 1996, Microbiological reviews.

[43]  C. Edwards,et al.  Direct measurements of natural planktonic bacterial community viability by flow cytometry , 1995, Applied and environmental microbiology.

[44]  R. R. Colwell,et al.  Viable but Non-Culturable Vibrio cholerae and Related Pathogens in the Environment: Implications for Release of Genetically Engineered Microorganisms , 1985, Bio/Technology.

[45]  E. Delong,et al.  Phylogenetic stains: ribosomal RNA-based probes for the identification of single cells. , 1989, Science.

[46]  A. Pinder,et al.  Detection of Salmonella typhimurium in dairy products with flow cytometry and monoclonal antibodies , 1994, Applied and environmental microbiology.

[47]  R. Venezia,et al.  Rapid detection of herpes simplex virus in clinical samples by flow cytometry after amplification in tissue culture , 1990, Journal of clinical microbiology.

[48]  Simon C Watkins,et al.  Current Protocols In Cytometry , 1997 .

[49]  S. Quake,et al.  A microfabricated fluorescence-activated cell sorter , 1999, Nature Biotechnology.

[50]  M. Perry,et al.  Probes for Assessing Single-Cell Primary Production: Antibodies Against Ribulose-1,5-Bisphosphate Carboxylase (RuBPCase) and Peridinin/Chlorophyll A Protein (PCP) , 1988 .

[51]  Sallie W. Chisholm,et al.  A novel free-living prochlorophyte abundant in the oceanic euphotic zone , 1988, Nature.

[52]  Linda Peterson,et al.  Evaluation of four commercial antibodies , 1999 .

[53]  D. Lloyd,et al.  YEAST VITALITY DURING CIDER FERMENTATION: TWO APPROACHES TO THE MEASUREMENT OF MEMBRANE POTENTIAL , 1995 .

[54]  Howard M. Shapiro,et al.  Practical Flow Cytometry , 1985 .

[55]  G. Suhren,et al.  First experiences with automatic flow cytometric determination of total bacterial count in raw milk. , 1998 .

[56]  R. Amann,et al.  Optimizing fluorescent in situ hybridization with rRNA-targeted oligonucleotide probes for flow cytometric identification of microorganisms. , 1993, Cytometry.

[57]  W. B. Betts,et al.  Protozoan parasites and water , 1995 .

[58]  D. J. Mason,et al.  The ability of membrane potential dyes and calcafluor white to distinguish between viable and non-viable bacteria. , 1995, The Journal of applied bacteriology.

[59]  G. Pettipher Preliminary evaluation of flow cytometry for the detection of yeasts in soft drinks , 1991 .

[60]  R. Christen,et al.  Assessment of the state of activity of individual bacterial cells by hybridization with a ribosomal RNA targeted fluorescently labelled oligonucleotidic probe , 1994 .

[61]  D. Kell,et al.  The use of 5-cyano-2,3-ditolyl tetrazolium chloride and flow cytometry for the visualisation of respiratory activity in individual cells of Micrococcus luteus , 1993 .

[62]  A. Ellington,et al.  RNA Selection: Aptamers achieve the desired recognition , 1994, Current Biology.

[63]  J. Goding,et al.  Monoclonal Antibodies: Principles and Practice , 1996 .

[64]  N. Ashbolt,et al.  Application of flow cytometric methods for the routine detection of Cryptosporidium and Giardia in water. , 1994, Cytometry.

[65]  D. Veal,et al.  Evaluation of fluorochromes and excitation sources for immunofluorescence in water samples. , 1997, Cytometry.

[66]  Daniel Vaulot,et al.  The importance of Prochlorococcus to community structure in the central North Pacific Ocean , 1994 .

[67]  R. Amann,et al.  Combination of rRNA-Targeted Hybridization Probes and Immuno-Probes for the Identification of Bacter , 1996 .

[68]  L. Jespersen,et al.  USE OF FLOW CYTOMETRY FOR RAPID ESTIMATION OF INTRACELLULAR EVENTS IN BREWING YEASTS , 1994 .

[69]  C Laplace-Builhé,et al.  Application of flow cytometry to rapid microbial analysis in food and drinks industries , 1993, Biology of the cell.

[70]  J. Vives-Rego,et al.  Flow cytometric assessment of Escherichia coli and Salmonella typhimurium starvation-survival in seawater using rhodamine 123, propidium iodide, and oxonol , 1995, Applied and environmental microbiology.

[71]  D. Deere,et al.  Evaluation of the suitability of bis-(1,3-dibutylbarbituric acid) trimethine oxonol, (diBA-C4(3)-), for the flow cytometric assessment of bacterial viability. , 1995, FEMS microbiology letters.

[72]  B. Ward,et al.  Comparison of Nucleic Acid Hybridization and Fluorometry for Measurement of the Relationship between RNA/DNA Ratio and Growth Rate in a Marine Bacterium , 1993, Applied and environmental microbiology.

[73]  A. Pinder,et al.  Detection of low levels of specific Salmonella species by fluorescent antibodies and flow cytometry. , 1994, The Journal of applied bacteriology.

[74]  P. Hunter,et al.  Cytometric Evaluation of Antifungal Agents , 1993 .

[75]  D. Veal,et al.  Viable Cryptosporidium parvum oocysts exposed to chlorine or other oxidising conditions may lack identifying epitopes. , 1998, International journal for parasitology.

[76]  J. Pratt,et al.  Use of fluorochromes for direct enumeration of total bacteria in environmental samples: past and present. , 1994, Microbiological reviews.

[77]  D A Stahl,et al.  Fluorescent-oligonucleotide probing of whole cells for determinative, phylogenetic, and environmental studies in microbiology , 1990, Journal of bacteriology.

[78]  T. Abee,et al.  Energy-dependent, carrier-mediated extrusion of carboxyfluorescein from Saccharomyces cerevisiae allows rapid assessment of cell viability by flow cytometry , 1994, Applied and environmental microbiology.

[79]  K. Schleifer,et al.  Probing activated sludge with oligonucleotides specific for proteobacteria: inadequacy of culture-dependent methods for describing microbial community structure , 1993, Applied and environmental microbiology.