Experimentally Validated Computational Fluid Dynamics Model for a Data Center With Cold Aisle Containment
暂无分享,去创建一个
[1] R. Schmidt,et al. Improved Computational Fluid Dynamics Model for Open-Aisle Air-Cooled Data Center Simulations , 2013 .
[2] Dustin W. Demetriou,et al. Evaluation of a data center recirculation non-uniformity metric using computational fluid dynamics , 2011 .
[3] Cullen E. Bash,et al. Modeling and Control for Cooling Management of Data Centers With Hot Aisle Containment , 2011 .
[4] B. Sammakia,et al. Effect of Under Floor Blockages on Data Center Performance , 2006, Thermal and Thermomechanical Proceedings 10th Intersociety Conference on Phenomena in Electronics Systems, 2006. ITHERM 2006..
[5] Vaibhav K. Arghode,et al. Room Level Modeling of Air Flow in a Contained Data Center Aisle , 2014 .
[6] Madhusudan K. Iyengar,et al. Comparison of Numerical Modeling to Experimental Data in a Small Data Center Test Cell , 2009 .
[7] Yogendra Joshi,et al. Experimental Characterization of Various Cold Aisle Containment Configurations for Data Centers , 2015 .
[8] I. E. Idelchik,et al. Flow Resistance : A Design Guide for Engineers , 1989 .
[9] V. K. Arghode,et al. Thermal Characteristics of Open and Contained Data Center Cold Aisle , 2013 .
[10] Bahgat Sammakia,et al. Impact of Cold Aisle Containment on Thermal Performance of Data Center , 2013 .
[11] Bahgat Sammakia,et al. A Numerical Steady State and Dynamic Study in a Data Center Using Calibrated Fan Curves for CRACs and Servers , 2013 .
[12] Bahgat Sammakia,et al. Comparative Analysis of Different Data Center Airflow Management Configurations , 2005 .
[13] Joonwon Lee,et al. A CFD-Based Tool for Studying Temperature in Rack-Mounted Servers , 2008, IEEE Transactions on Computers.
[14] Bahgat Sammakia,et al. Open and Contained Cold Aisle Experimentally Validated CFD Model Implementing CRAC and Server Fan Curves for a Data Center Test Laboratory , 2013 .
[15] Xuanhang Zhang,et al. Effect of rack modeling detail on the numerical results of a data center test cell , 2008, 2008 11th Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems.
[16] Sami Alkharabsheh,et al. Experimental characterization of pressure drop in a server rack , 2014, Fourteenth Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (ITherm).
[17] S. Shrivastava,et al. Utilizing practical fan curves in CFD modeling of a data center , 2013, 29th IEEE Semiconductor Thermal Measurement and Management Symposium.
[18] M. Ibrahim,et al. Quantitative comparison of air containment systems , 2012, 13th InterSociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems.
[19] S. Patankar. Airflow and Cooling in a Data Center , 2010 .
[20] Sami Alkharabsheh,et al. Dynamic models for server rack and CRAH in a room level CFD model of a data center , 2014, Fourteenth Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems (ITherm).
[21] Roger R. Schmidt,et al. A methodology for the design of perforated tiles in raised floor data centers using computational flow analysis , 2001 .
[22] R. Schmidt,et al. Experimental-Numerical Comparison for a High-Density Data Center: Hot Spot Heat Fluxes in Excess of 500 W/FT2 , 2006, Thermal and Thermomechanical Proceedings 10th Intersociety Conference on Phenomena in Electronics Systems, 2006. ITHERM 2006..
[23] Jeffrey Rambo,et al. Numerical Modeling of Perforated Tile Flow Distribution in a Raised-Floor Data Center , 2010 .
[24] Cullen E. Bash,et al. Computational Fluid Dynamics Modeling of High Compute Density Data Centers to Assure System Inlet Air Specifications , 2001 .
[25] Dustin W. Demetriou,et al. Optimization of Enclosed Aisle Data Centers Using Bypass Recirculation , 2012 .
[26] Magnus K. Herrlin,et al. Rack cooling effectiveness in data centers and telecom central offices : The rack cooling index (RCI). Discussion , 2005 .
[27] Jeffrey Rambo,et al. Modeling of data center airflow and heat transfer: State of the art and future trends , 2007, Distributed and Parallel Databases.
[28] Waleed Abdelmaksoud. Experimental and Numerical Investigations of the Thermal Environment in Air-cooled Data Centers , 2012 .
[29] S. Patankar. Numerical Heat Transfer and Fluid Flow , 2018, Lecture Notes in Mechanical Engineering.
[30] Roger R. Schmidt,et al. Distributed Leakage Flow in Raised-Floor Data Centers , 2005 .
[31] Madhusudan K. Iyengar,et al. Comparison Between Numerical and Experimental Temperature Distributions in a Small Data Center Test Cell , 2007 .