Precalibration evaluation procedures for mid-infrared milk analyzers.

The purpose of this paper is to present a detailed account of the precalibration procedures developed and implemented by the USDA Federal Milk Market Administrators (FMMA) for evaluating mid-infrared (MIR) milk analyzers. Mid-infrared analyzers specifically designed for milk testing provide a rapid and cost-effective means for determining milk composition for payment and dairy herd improvement programs. These instruments determine the fat, protein, and lactose content of milk, and enable the calculation of total solids, solids-not-fat, and other solids. All MIR analyzers are secondary testing instruments that require calibration by chemical reference methods. Precalibration is the process of assuring that the instrument is in good working order (mechanically and electrically) and that the readings before calibration are stable and optimized. The main components of precalibration are evaluation of flow system integrity, homogenization efficiency, water repeatability, zero shift, linearity, primary slope, milk repeatability, purging efficiency, and establishment of intercorrection factors. These are described in detail and apply to both filter-based and Fourier transform infrared instruments operating using classical primary and reference wavelengths. Under the USDA FMMA Precalibration Evaluation Program, the precalibration procedures were applied longitudinally over time using a wide variety of instruments and instrument models. Instruments in this program were maintained to pass the criteria for all precalibration procedures. All instruments used similar primary wavelengths to measure fat, protein, and lactose but there were differences in reference wavelength selection. Intercorrection factors were consistent over time within all instruments and similar among groups of instruments using similar primary and reference wavelengths. However, the magnitude and sign of the intercorrection factors were significantly affected by the choice of reference wavelengths.

[1]  D. Biggs,et al.  Alternative methods for infrared analysis of fat in milk: interlaboratory study. , 1989, Journal - Association of Official Analytical Chemists.

[2]  D. Biggs Performance specifications for infrared milk analysis. , 1979, Journal - Association of Official Analytical Chemists.

[3]  D. Barbano,et al.  Infrared analysis of milk : effect of homogenizer and optical filter selection on apparent homogenization efficiency and repeatability , 1995 .

[4]  D.-A. Biggs,et al.  Analysis of fat, protein, lactose & total solids by infra-red absorption , 1987 .

[5]  J. L. Clark,et al.  Infrared Milk Analysis — Challenges for the Future , 1989 .

[6]  D. Barbano,et al.  Effect of infrared analyzer homogenization efficiency on linearity of uncorrected fat A and fat B signals. , 1994, Journal of AOAC International.

[7]  Y. Agnet Fourier transform infrared spectrometry : A new concept for milk and milk product analysis , 1998 .

[8]  J. D. S. Goulden,et al.  Analysis of milk by infra-red absorption , 1964, Journal of Dairy Research.

[9]  D. Barbano,et al.  Performance of homogenizers in infrared milk analyzers : a survey , 1993 .

[10]  L. Sjaunja Studies on Milk Analyses of Individual Cow Milk Samples , 1984 .

[11]  Title 21—food and Drugs § 355a , 2022 .

[12]  Pieter Walstra,et al.  Dairy chemistry and physics , 1984 .

[13]  P. Walstra,et al.  Dairy chemistry & physics. , 1984 .

[14]  W. Horwitz Official Methods of Analysis , 1980 .

[15]  D. Barbano,et al.  Variation in the ash and nonprotein nitrogen content of milk, and use of milk protein content to predict milk ash content. , 1990 .

[16]  Y. Agnet Fourier transform infrared spectrometry , 1998 .

[17]  L. Sjaunja Studies on Milk Analyses of Individual Cow Milk Samples: III. The Effect of Different Treatments on Infrared Analyses , 1984 .

[18]  D. Barbano,et al.  Effect of infrared analyzer homogenization efficiency on repeatability of uncorrected fat A and fat B signals. , 1994, Journal of AOAC International.

[19]  D. Barbano,et al.  A quantitative linearity evaluation method for infrared milk analyzers , 1993 .

[20]  農業技術研究所 Official methods of analysis of fertilizers , 1982 .