Short Radius Centrifuges - A New Approach for Life Science Experiments under Hyper-g Conditions for Applications in Space and Beyond

A broad variety of countermeasures on the effects of weightlessness on human physiology have been developed and applied in the course of space exploration. Devices like treadmills, stretch ropes etc. have several disadvantages in common: they require a significant amount of crew time and they may not efficiently counteract the degradation of physiological structures and cellular functions. Some methods even include potentially painful or uncomfortable procedures for the astronauts. Thus, the application of Artificial Gravity (AG) generated by short radius centrifuges (they fit into space vessels) has been discussed and proposed by a number of scientists and space agencies as an alternative countermeasure during long-term space missions. Although there is a profound knowledge concerning, e.g., the cardiovascular system and immune responses acquired on long radius centrifuges, there is a remarkable lack of knowledge concerning the same issues on devices operating with short radius. In strict contrast to long radius centrifuges, there is a significant gravity gradient in the head-to-toe axis which comes along with the short radius and higher relative rotation velocity. Thus it is of utmost importance to continue investigating the effects of AG, especially by use of short radius centrifuges. The Short Arm Human Centrifuge (SAHC) at the German Aerospace Center (DLR) in Cologne, Germany, is the most advanced type of short radius centrifuges presently commercially available. Experience gained so far using the SAHC at DLR revealed that future projects on centrifuge devices with short radius should aim at a clear identification of the threshold level of the g-load, which is necessary to efficiently counteract the degradation of physical structures and an efficient support of cellular functions. A satisfying result would be combined countermeasure methods applied at a threshold concerning g-load and exposition time in the course of long-term sojourn in microgravity. Another future control or monitoring method to exactly dose AG training is heart rate variability, which offers an insight into neurovegetative and cardiovascular regulation. Centrifuges like the SAHC are also useful platforms to accommodate small biological experiments, e.g., experiments addressing the response of cultured cells to hypergravity. Here, we briefly review the issue of short radius centrifuges and also address our experience hitherto gained during a number of scientific projects carried out at the SAHC at DLR.

[1]  B. Seps,et al.  Parasympathetic heart rate modulation during parabolic flights , 2003, European Journal of Applied Physiology.

[2]  G. Fucà,et al.  The venous system is the main determinant of hypotension in patients with vasovagal syncope. , 2006, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[3]  F. Iellamo,et al.  Muscle metaboreflex contribution to cardiovascular regulation during dynamic exercise in microgravity: insights from mission STS‐107 of the space shuttle Columbia , 2006, Journal of Physiology.

[4]  F E Guedry,et al.  Microgravity vestibular investigations: perception of self-orientation and self-motion. , 1997, Journal of vestibular research : equilibrium & orientation.

[5]  A E Aubert,et al.  Respiratory modulation of cardiovascular rhythms before and after short‐duration human spaceflight , 2007, Acta physiologica.

[6]  L R Young,et al.  Artificial gravity: head movements during short-radius centrifugation. , 2001, Acta astronautica.

[7]  Ruth Hemmersbach,et al.  PMT (Photomultiplier) Clinostat , 2011 .

[8]  L. Rowell Human Cardiovascular Control , 1993 .

[9]  G. Jacob,et al.  Orthostatic Hypercoagulability: A Novel Physiological Mechanism to Activate the Coagulation System , 2008, Hypertension.

[10]  A. Horn Vorbereitungen für das Biolab Experiment TRIPLE LUX A: Hardwareentwicklung, Kalibrierung und biologische Bodenkontrollen , 2011 .

[11]  Richard S. Johnston,et al.  Biomedical results from Skylab , 1977 .

[12]  J. Shoemaker,et al.  Differential Effect of head‐up tilt on Cardiovagal and Sympathetic Baroreflex Sensitivity in Humans , 2003, Experimental physiology.

[13]  B. Seps,et al.  Heart rate variability during gravity transitions , 2002, Computers in Cardiology.

[14]  Jens Jordan,et al.  Orthostatic heart rate responses after prolonged space flights , 2011, Clinical Autonomic Research.

[15]  Douglas A. Lawrence,et al.  Generating artificial gravity onboard the Space Shuttle , 2007 .

[16]  Kuno Hottenrott Herzfrequenzvariabilität im Sport : Prävention, Rehabilitation, Training : Symposium am 8. Dezember 2001 in Marburg , 2002 .

[17]  G. Antonutto,et al.  The energetics of cycling on Earth, Moon and Mars , 2011, European Journal of Applied Physiology.

[18]  Suzanne M. Schneider,et al.  Space physiology VI: exercise, artificial gravity, and countermeasure development for prolonged space flight , 2012, European Journal of Applied Physiology.

[19]  K Hirayanagi,et al.  Effects of daily 2-Gz load on human cardiovascular function during weightlessness simulation using 4-day head-down bed rest. , 1999, Uchu koku kankyo igaku.

[20]  G. Breithardt,et al.  Heart rate variability: standards of measurement, physiological interpretation and clinical use. Task Force of the European Society of Cardiology and the North American Society of Pacing and Electrophysiology. , 1996 .

[21]  J. Stewart,et al.  Increased vasoconstriction predisposes to hyperpnea and postural faint. , 2008, American journal of physiology. Heart and circulatory physiology.

[22]  A. Malliani,et al.  Heart rate variability. Standards of measurement, physiological interpretation, and clinical use , 1996 .

[23]  Richard L Summers,et al.  Theoretical analysis of the mechanisms of a gender differentiation in the propensity for orthostatic intolerance after spaceflight , 2010, Theoretical Biology and Medical Modelling.

[24]  Xavier Neyt,et al.  Respiratory sinus arrhythmia on the ESA-short-arm human centrifuge , 2009, IEEE Engineering in Medicine and Biology Magazine.

[25]  K Hirayanagi,et al.  Usefulness of daily +2Gz load as a countermeasure against physiological problems during weightlessness. , 2001, Acta astronautica.

[26]  Theodore Raphan,et al.  Ocular counterrolling induced by centrifugation during orbital space flight , 2001, Experimental Brain Research.

[27]  Theodore Raphan,et al.  The human response to artificial gravity in a weightless environment: Results from the Neurolab centrifugation experiments , 2001 .